My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7100 HARDESON RD 2021 Plans 2025-03-27
>
Address Records
>
HARDESON RD
>
7100
>
Plans
>
7100 HARDESON RD 2021 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 8:41:10 AM
Creation date
3/17/2025 11:31:34 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Permit
B2107-002
Year
2021
Notes
COMMUNITY TRANSIT ADMIN BLDG RENOVATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Otak <br /> ii► <br /> Otak Architects,Inc. <br /> 808 SW Third Avenue,Suite 300 <br /> Portland,OR 97204 <br /> main 503.287.6825 <br /> www.otak.com <br /> 0 . <br /> 1 'i c. <br /> 4 o <br /> •♦♦♦♦♦♦♦♦♦♦ �i1 RIM=43860 q� <br /> ♦:♦♦♦♦♦♦♦ :♦:♦:♦fir. ,••j <br /> 22 <br /> f 4. <br /> II <br /> I <br /> II <br /> I <br /> i © mP) I <br /> co <br /> °'I <br /> ♦♦♦♦♦♦♦♦♦♦♦ ♦♦ , I CONSULTANT <br /> ♦♦♦♦♦♦♦♦�♦♦♦♦:, <br /> Cl)v,^ <br /> ♦' 2 o I Z <br /> o <br /> ♦. I W <br /> 2 <br /> ., <br /> I <br /> ::LLANO„i <br /> i ) I W <br /> Hlht=44i 13 A .411 A I <br /> N N I m 0 <br /> I D (TPI <br /> 4-4 <br /> ►� (Al <br /> ♦• 1 /Ce <br /> ��� A ♦ A I _ V <br /> ♦♦♦♦y9` is• <br /> i Z <br /> Oi♦i♦i ♦ 1 El <br /> ♦♦♦♦♦♦♦ ♦' I 0 <br /> c,E,r,;rp T ♦♦♦♦♦♦♦♦ A EXISTING ID-INCH PCCP '♦' 4, <br /> CT.:-44^,40 ��♦♦♦♦♦♦♦♦♦♦��♦ O) .: O7 1 <br /> �♦ I <br /> in CLEANOUT -. .I., �; -'I1 CCIZ <br /> ♦• A ►� — .4I — a. <br /> . co Z <br /> ♦, ♦, I illHIM=43.44 Q O <br /> m'(TYP.) is ..; 4'Pvc 1 1 as I Q —I♦' Q I <br /> 0El <br /> ♦ o O <br /> <x"' �♦• ,�� I W O W <br /> a <br /> ,,c1 i <br /> 4 P V IY o <br /> b s � 7�Z 177�1Z�� L i CATCH BASIN ss Q <br /> ILY l RIM=433 i. Q <br /> kt <br /> !1i6S-RUCTED C <br /> Ufll <br /> -6 Ut <br /> E I Z <br /> z IX F Q <br /> I Et =Lu U <br /> 3 MATCHLINE SEE SHEET C1.02 W o W C/) <br /> �w I-M LU <br /> 9 <br /> O <br /> TITLE <br /> U TESC& DEMOLITION NOTES GENERAL NOTES LEGEND DATE DESCRIPTION <br /> 8232021 PERMIT <br /> 6 0 REMOVE EXISTING TREE. 14 REMOVE EXISTING ECOLOGY BLOCK. 1. EXISTING TWO STORY BUILDING TO REMAIN.PROTECT 1212022 BID ISSUE <br /> U DURING CONSTRUCTION. — CLEARING AND GRUBBING <br /> 00 REMOVE EXISTING WALL. 15 SEE DETAIL 2 ON SHEET G4.01 FOR REMOVAL OF EXISTING MODULAR BUILDINGS <br /> cQ❑a <br /> i REMOVE EXISTING TRAFFIC CURB. AND DEMOLITION OF CONNECTING STRUCTURES. 2. NSEE OTES. PAVEMENT <br /> C0.02 FOR CITY OF EVERETT STANDARD PAVEMENT REMOVAL <br /> INSTALL TEMPORARY CHAINLINK FENCE PER DETAIL 11 ON SHEET C7.01. <br /> sao a REMOVE EXISTING CONCRETE SIDEWALK. 16 3. STORM DRAIN INLET PROTECTION SHALL BE PROVIDED <br /> n aINSTALL STRAW WATTLE PER WSDOT STD PLAN 1-30.30-02 WITH SANDBAG PLACED AND MAINTAINED AT ALL EXISTING AND PROPOSED SAWCUT <br /> c a REMOVE EXISTING PAINT LINE. ON TOP TO SECURE THE WATTLE. STORM INLET PRIOR TO AND FOR THE DURATION OF <br /> CONSTRUCTION OPERATIONS.PROPOSED CATCH BASINS o TREE PROTECTION <br /> SAWCUT AND REMOVE EXISTING PAVEMENT.APPROX.LIMITS PER PLAN. 3INSTALL STORM DRAIN INLET PROTECTION PER COE STD DETAIL 210. AND PROTECTION MEASURE NOT SHOWN IN PLAN FOR X TREE REMOVAL REVISIONS <br /> MS,BS,AL,EH MDC <br /> 7❑ SALVAGE EXISTING LECTRI A AND POLE,DEMOLISH POLE 18 REMOVE EXISTING WHEEL STOP. X TEMPORARY CHAINLINK FENCE DRAWN BY CHECK BY <br /> ?-. FOUNDATION.SEE ELECTRICAL PLAN FOR DETAILS. 4. ALL EXISTING LANDSCAPE BOULDERS(NOT SHOWN)TO <br /> x 20 REMOVE AND SALVAGE EXISTING SIGN. BE SALVAGED FOR RELOCATION ON-SITE.REFER TO BID ISSUE <br /> B0 EXISTING CONCRETE SIDEWALK TO REMAIN,PROTECT DURING PLANTING PLANS FOR RELOCATED BOULDER LOCATIONS. STATUS <br /> STRAW WATTLE <br /> STATUS <br /> CONSTRUCTION. IIII----21----LLLL REMOVE EXISTING DUMPSTER AND TRASH ENCLOSURE <br /> 9a PROTECT EXISTING TREE PER DETAIL 3 ON SHEET L2.10. RELOCATE EXISTING LIGHT AND SIGNAL POLE.SEE SHEET G4.01 FOR NEW S. PARE APPROXIMATE.AVEMENT REMOVAL SAWCUT THE CONCRETE D SAWCUTTING LIMIT SHOWN STORM DRAIN INLET PROTECTION 1212022 <br /> Eill DATE <br /> _ LOCATION. PAVEMENT FOR LANDSCAPING,REMOVE THE PAVEMENT 32880J <br /> 10 EXISTING UTILITY TO REMAIN,PROTECT DURING CONSTRUCTION. UP TO 6'BEHIND THE PROPOSED BACK OF CONCRETE <br /> 184 23 EXISTING RAILING TO REMAIN,PROTECT DURING CONSTRUCTION. CURB LINE. PROJECTROJE NUMBER <br /> o 11 CONSTRUCTION. <br /> ON LINK FENCE TO REMAIN,PROTECT DURING 24 EXISTING MONUMENT SIGN TO BE REMOVED AND RELOCATED ON-SITE. 6. BMP 75.13 POST-CONSTRUCTION SOIL QUALITY AND • V 1 a O 1 <br /> DEPTH SHALL BE APPLIED FOR SOIL PREPARATION. <br /> 12 EXISTING CURB TO REMAIN,PROTECT DURING CONSTRUCTION. 26 REMOVE EXISTING STONE BENCHES AND FLAGSTONE PATH. CONTRACTOR SHALL PRIORITIZE THE REUSE OF EXISTING <br /> Know Woes below. aEXISTING SIGN TO BE REFURBISHED PER DETAIL 2 REFERENCE ED1.01 FOR DEMO OF ELECTRICAL SERVICE TO MODULAR BUILDINGS. TOPSOIL,PER CITY OF EVERETT REQUIREMENTS.(COESTANDARD PLAN 202 AND 203) 20 0 20 40 el 20210TAK.INC. <br /> '$ ON SHEET L1.04. <br /> CBI)before you dig. 0 EXISTING SIGN TO REMAIN. HORZ mmle drawing is not 2r,S.d has been <br /> a SCALE IN FEET redoced,enI,,8ed.Scale accordingly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.