Laserfiche WebLink
GENERAL NOTES Otak <br /> SEE SHEET L3.01 FOR CONTINUATION <br /> vL L11 v",, ,,fL'Y"vv,n' 1. CONTRACTOR SHALL VERIFY STATIC WATER PRESSURE OF 88 PSI �„ <br /> 1-1/4"..et .a • AT EXISTING WATER METER/DOUBLE CHECK VALVE ASSEMBLY. <br /> 19.0 C-2 NSTALL IRRIGATION HEADS AND 14O C-3 16.0 C-4 14.0 C 12.0 C-6 NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO COMMENCING <br /> DIRECT BORE ALL IRRIGATION • WITH INSTALLATION. Otak Architects,Inc. <br /> SLEEVES TO PARKING AREA GPM 1' LATERAL LINE IN SOIL ABOVE GPM �• GPM 1• GPM T GPM 1' 2. AN EXISTING IRRIGATION SYSIEM EXISTS ON SITE. SALVAGEABLE <br /> PLANTERS(TYP) R-TANK STORMWATER DETENTION • PORTIONS OF THE EXISTING MAINLINE AND LATERAL LINES MAY 808 SW Third Avenue,Suke 300 <br /> • FOOTPRINT Portland,OR 97204 <br /> 'p,' BE USED BY THE CONTRACTOR WHEN POSSIBLE. main 503.287.682597204 <br /> 1-114" 3. EXISTING IRRIGATION STATIONS MAY BE UTIUZED AS LONG AS <br /> y INSTALL IRRIGATION MAINLINE AT "� .� 'nmw.otak.cam <br /> • 12'OFF BACK OF CURB �! Q REPAIRS ARE MADE AND THE SYSTEM IS FULLY OPERATIONAL <br /> 4. IRRIGATION CONTROLLER SHALL BE LOCATED IN MECHANICAL <br /> of ROOM AND CAN UTILIZE DOSING WIRE SLEEVE AND RAIN OF wASy <br /> _ 1-vz' C. -, - - 5. SYSTEM OPERATING PRESSURE 30-40 PSI. PtP tN AViv, 'I'•,ci' <br /> • -'-__• I - - 0 • • ' - 0 0 0 0 0 0 0 ----aa O 0 - O- _CO_0 0 0 Q i 6. LATERAL PIPE SIZING SHALL BE 'FOR FLOWN UNDER 10 GPM. m2 �� u� °cp 2 <br /> • ' --- -..- -- _ LATERAL PIPE SIZING FOR FLOWS GREATER THAN 10 GPM IS <br /> _— - I fib` 1-1I4' <br /> If 1' / IT - - - _ �- I - _ -_ - LABELED ON PLANS. CONTRACTOR SHALL VERIFY LATERAL PIPE iV. + <br /> '. ��- f • -- f''�*'''�`' - - - - ' ito C-7 SIZING REQUIREMENTS IN FIELD PER THE PVC PIPE SCHEDULE G, '4 ~ <br /> •' '/ \• INSTALL IRRIGATION HEADS AT glom, 1114 v c ', SHOWN ON IRRIGATION LEGEND. n • ,f'v\ <br /> -,i BACK SIDE OF ELECTRIC VEHICLE • -.- _-� _• RF -. 0 _ . S`�°B� p3-- 1���d` <br /> CHARGING STSTIONS(TYP.) .• _ r- G —Aril IRRIGATION NOTES 4A DsGAPE'' <br /> _ DIRECT BORE IRRIGATION - � 1-i14• ,i,�� <br /> ' SLEEVES AT EXISTING SIDEWALK I 0 po e,* I. <br /> • • • •. --_ - i PA�,i.„ O WALL MOUNT IRRIGATION CONTROLLER STAMP <br /> 19,Q --- C-12 ® y CON WIRING,SEL DETAIL SHEET L3.10 <br /> 2O CONTROL VALVE ASSEMBLY, <br /> • O. <br /> GPM T EXISTING T ( SEE DETAIL SHEET L3.10 <br /> \ omw I ! e I Cl QUICK COUPLER, <br /> per, I \> SEE DETAIL SHEET L3.11 <br /> '•7 •' +D1C 4O BALL VALVE, <br /> J 4 I,.r � OR� SEE DETAIL SHEET L3.11 <br /> O TYPICAL TRENCHING IN LANDSCAPE, CONSULTANT <br /> SEE DETAIL SHEET L3.11 <br /> • \--- <br /> 'f EXISTING <br /> 1, • <br /> 6 a 6O TYPICAL TRENCHING UNDER PAVEMENT, CO <br /> PROVIDE NEW SLEEVE AND REPAIR •1.. • <br /> *** nn -El I <br /> I SEE DETAIL SHEET L3.11 <br /> EXISTING IRRIGATION LATERAL LINES <br /> AT NEW PEDESTRIAN ROUTE '1: Inii <br /> I O Z <br /> • <br /> a 7 POP-UP HEAD, <br /> r 'RT' , SEE DETAIL SHEET L3.11 <br /> -- C- K * O O - - - III i0 MANUAL DRAIN VALVE, C <br /> I " " 11111 '1' SEE DETAIL SHEET L3.11 C <br /> • 1 9O SLEEVE FOR IRRIGATION PIPE&WIRE• W <br /> EXISTING T ,. _ • I r a • <br /> — � • SEE DETAIL SHEET L3.11 > <br /> • PROVIDE NEW SLEEVE AND REPAIR PROVIDE NEW SLEEVE AND REPAIR • 1 _' <br /> * EXISTING IRRIGATION LATERAL LINES EXISTING IRRIGATION LATERAL LINES -O I r O <br /> AT NEW PEDESTRIAN ROUTE * AT NEW PEDESTRIAN ROUTE I EQUIPMENT LEGEND �/ <br /> 0 O 1-1V4' HUNTER MP800SR-90 ROTARY SPRAY 0- <br /> I O NOZZLE 6'-16' ON PRO-SPRAY PRS30 6" 5 <br /> • <br /> MAINTAIN EXISTING O • _ _ -- _ -I_ 11 POP-UP BODY(0.23-0.42 GPM) ` <br /> IRRIGATION IN THIS AREA - • I II O HUNTER MP800SR-360 ROTARY SPRAY <br /> MAINTAIN EXISTING • • 0 I NOZZLE 6'-16' ON PRO-SPRAY PRS30 6" <br /> IRRIGATION IN THIS AREA * • - ... <br /> - POP-UP BODY(0.78 GPM) <br /> • <br /> * r MAINTAIN EXISTING O' ash!�• L1 HUNTER MPSS530 SIDE STRIP ROTARY Z <br /> *** IRRIGATION IN THIS AREA 1-1/4' , r : - V I SPRAY NOZZLE ON PRO-SPRAY PRS30 <br /> • . . • <br /> *•* •* ** ;�•�-• •,—, 6"POP-UP BODY(0.44 GPM) 0* * a • <br /> * + **• •* 0 0 0 0 N HUNTER MPLCS515 LEFT CORNER STRIP <br /> H® O - / ROTARY SPRAY NOZZLE ON PRO-SPRAY PRS30 J <br /> 1-t12" -1 -- - �-114" * 1-1/4" 6" POP-UP BODY(0.22 GPM) <br /> o • Ci O Ir • 0 0 • 0 O 10 0 0 O O- _ SO <br /> MW * - . . * * �R* YA,I, I, / - - — _ - - CI HUNTER MPRCS515 RIGHT CORNER STRIP CO <br /> r _ '� - Cam_ ROTARY SPRAY NOZZLE ON PRO-SPRAY PRS30 <br /> , * * ` * ** 6"POP-UP BODY(0.22 GPM) Z <br /> * i a .** J I• • <br /> GPM T • HUNTER MSBN-10H MULTI-STREAM C <br /> .*•**'• • • • ���III �' G <br /> BUBBLER NOZZLE ON PRO-SPRAY <br /> PRS30 6"POP-UP BODY(1.0 GPM) Q <br /> • MN 12.0 C-� eo` Rd-1W 1 HUNTER MSBN-50H MULTI-STREAM <br /> • <br /> IS.O C-9 BUBBLER NOZZLE ON PRO-SPRAY <br /> • <br /> GPM T P. GPM 1' PRS30 6"POP-UP BODY(0.5 GPM) \/ <br /> • I pDC POINT OF CONNECTION; W <br /> -.,..- \`nQ C-11 AT EXISTING WATER METER/ <br /> ^ r d i - DOUBLE CHECK VALVE ASSEMBLY W p Z <br /> d 4 1r GPM �' PROVIDE MASTER VALVE: BUCKNER/SUPERIOR a Q <br /> ` • 1, f-1 -" - MODEL 3100150(NORMALLY OPEN) ♦ ' 0 o <br /> a '-br' r PROVIDE FLOW SENSOR:RAIN BIRD v Z NI 0- <br /> LJ x -- MODEL FS1 SOB J O Z <br /> fJ <br /> o " ITIIRRIGATION CONTROLLER: 16 STATIONS J W 0 <br /> (WALL MOUNT) WITH RAIN SENSOR p <br /> RAIN BIRD ESPLXMSMI2 WITH ADDEONALCe z 4 STATION MODULE W =w o <br /> o �D MANUAL DRAIN VALVE: W O <br /> �� CHAMPION 100R5-150Y(1-t/2" _o <br /> i (8) ISOLATOR wBALL VALVE: r W <br /> C) <br /> 0 ASSEMBLY TITLE <br /> RAIN BIRD PEB CONTROL VALVE <br /> a DATE DESCRIPTION <br /> 1 t RAIN BIRD 44-LRC 6/23/2021 PERMIT <br /> QUICK COUPLER ASSEMBLY 121202 PE ISSUE <br /> ifi <br /> `6SCHEDULE 40 IRRIGATION SLEEVING <br /> HARDESON RRID — SCHEDULE 40 MAINUNE(1.5") <br /> o SCHEDULE 40 LATERAL ONES <br /> a <br /> o <br /> IRRIGATION PIPE SIZING <br /> 273 <br /> P.V.C. PIPE SCHEDULE <br /> el PIPES ARE TO BE SIZED ACCORDING TO G.P.M. REVISIONS <br /> .-.6, (GALLONS PER MINUTE) DEMAND DOWN UNE. MS.BS.AL,EH MDC <br /> a <br /> - FLOW VELOCITIES ARE NOT TO EXCEED 5' PER DRAWN By CHECK BY <br /> Y SECOND. BID ISSUE <br /> STATUS <br /> SCHEDULE 40 P.V.C. MAINUNE& LATERALS. 121n022 <br /> el; <br /> DATE <br /> E 81i G.P.M. - -- PIPE SIZE <br /> 32880J <br /> O-8 3/4" PROJECT NUMBER <br /> le ,2_ 22 , ,/4„ L3 02 <br /> 23- 30 1 1/2" a <br /> Know what's below. 20 0 20 40 <br /> 31 - 50 2" <br /> 02021 OTAS.INC. <br /> Call before you dig. HOB <br /> If this drawing mza,as-,n has been <br /> 6= SCALE IN FEET reaucaaemargaa.Sule accordingly. <br />