My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7100 HARDESON RD 2021 Plans 2025-03-27
>
Address Records
>
HARDESON RD
>
7100
>
Plans
>
7100 HARDESON RD 2021 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 8:41:10 AM
Creation date
3/17/2025 11:31:34 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Permit
B2107-002
Year
2021
Notes
COMMUNITY TRANSIT ADMIN BLDG RENOVATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Otak <br /> Otak Architects,Inc. <br /> 808 SW Third Avenue,Suite 300 <br /> • FINISH GRADE FINISHED GRADE Portland,OR 24 <br /> main 8yv.03 v.287 olakco6825 <br /> 1"CLEAR,TYP. \ to K.com <br /> F=1TOP OF PAVING,CURB OR COBBLE EDGING <br /> 1Q DIAN VALVE BOX W/ THERMOPLASTIC,LOCKING 3 of JAWA Sh <br /> LVVCKI G LID �� QUICK COUPLER VALVE O�,N scytiti0 <br /> RUBBER COVER LABELED TWO PIECE BODY a.II r 1, I r ) y� FINISH GRADE/TOP OF MULCH �7-,Y �p �T.� b o <br /> .1�1/1(.�,,�,U 1�1,(.1,�1/1 a��,lAr aV(j(�l/d m <br /> F-1WITH"DO NOT DRINK" II <br /> EXTENSIONS(AS REQUIRED) ROUND PLASTIC VALVE o v 1�� POP-UP SPRAY OR ROTOR HEAD , 4 4 : <br /> STAINLESS STEEL BOX 6"DIA.X 8"DEEP 6� ' 'I' <br /> HOSE CLAMP COLOR:GREEN PVC SCH 80 NIPPLE Apr <br /> 3/4" HOSE <br /> DRAIN (2 REQUIRED) 1 (LENGTH AS REQUIRED) Fo�nnsen cg�4• <br /> VALVE W/LONG iris <br /> OPPER TRACE WIRE III I z ,,,2, <br /> KEY FOR SCH 40 PVC MAIN LINE L r#mFACTORY PRE-ASSEMBLED STAMP <br /> OPERATION SEE SCH 80 PVC ELL ORGRAVEL BACKFILL FOR <br /> SPECS) ( • �/ PVC TRIPLE SWING ASSEMBLY <br /> Ihi , TEE W/REDUCER DRAINAGE 6"MIN.LAYER � PVC SCH.80 I <br /> Illi!�iII�_O hill I.'U (4)SCH 80 3/4 "PVC III <br /> THREADED RISER <br /> ligEN BETWEEN LLS W/PVC NIPPLES FACTORY PRE-ASSEMBLED �*; •,��r <br /> PVC TRIPLE SWING ASSEMBLY PVC LATERAL PIPE <br /> OUTFALL PIPE TO <br /> LIIIIIIIIIIII <br /> PVC SCH 40 TEE '�„ <br /> RAIN GARDEN <br /> 1/2 CU YD OF MINERAL #4 REBAR(30"MIN.) <br /> AGGREGATE TYPE 4 OVER ay` PVC MAINLINE PVC SCH 40 TEE OR ELL CONSULTANT <br /> GEOTEXTILE FABRIC <br /> CO <br /> -- MANUAL DRAIN VALVE 2 QUICK COUPLER VALVE ASSEMBLY 3 POP-UP HEAD I— <br /> ® NOT TO SCALE L3.11 NOT TO SCALE L3.11 NOT TO SCALE <br /> FINISH GRADE WC <br /> NATIVE BACKFILL \ G <br /> =Ill COLOR:GR STANDARD VALVEWCOPPERTRECE WIRE COLOR:GREEN 0 <br /> (FROM VALVE TO END OF ZONE) #3 REBAR STAKE TO MARK SLEEVE _ EXTENSIONS(AS REQUIRED) <br /> (PAINT TOP SAFETY ORANGE) �y <br /> z z LINE SIZE PVC BALL VALVE Li <br /> IlLEM13 z LATERAL LINE a <br /> C PAVEMENT PVCCH 4B SSW_-----A--_Iri <br /> UNION <br /> G MAINLINE 1- BACKFILL AS SPECIFIED BRASS "CH 40 PVC <br /> c IRRIGATION WIRING w V <br /> CONTROL WIRE <br /> SPECIFIED PIPE BEDDING2X LU SCHED.40 P.V.C.SLEEVE \ r Z <br /> NOTES: <br /> SIZE ill ICI I■I■IIII■MENIN it I:L INE CINOTES: °EXTEND IRRIGATION SLEEVE 6" PVC ADAPTER r 3. 1 <br /> ASSEMBLY ` <br /> SNAKE ALL P.V.C.PIPING IN TRENCHING. WHERE ELECTRICAL WIRING DOES NOT BEYOND EACH SIDE OF PAVING. UNION J NOTES: *EXCEPT © POINT OF <br /> TIE LOOSE 3'LOOP IN ALL IRRIGATION SHARE COMMON TRENCH,OVEREXCAVATE MAINLINE OR "DEPTH OF MAINLINE=18 /I CONNECTION APPURTENANCES. <br /> WIRING AT CHANGES IN DIRECTION TRENCH 2"MIN.AND BACKFILL WITH LATERAL PIPE 6"PEA GRAVEL USE TEFLON TAPE ON ALL m <br /> SPECIFIED BEDDING MATERIAL. a DEPTH OF LATERAL @ PAVING=14"MIN. <br /> GREATER THAN 30 DEG..UNTIE AFTER LOCATE ALL WIRING NOT IN COMMON THREADED FITTINGS. <br /> ALL CONNECTIONS HAVE BEEN MADE. TRENCHES ACCURATELY ON RECORD DWGS.. =DEPTH OF LINES UNDER DRIVING Z <br /> SURFACES=24"MIN. NOTE: <br /> BALL VALVE INSTALLATION UP FLOW FROM THE CROSS-CONNECTION CONTROL DEVICE SHALL <br /> RECEIVE ALL RIGID COPPER,TYPE L PIPE AND BRASS OR BRONZE FITTINGS AS REQUIRED. Cl <br /> TYPICAL TRENCHING IN LANDSCAPE AREAS 5 IRRIGATION SLEEVES UNDER PAVEMENT g BALL VALVE DETAIL <br /> L3.11 NOT TO SCALE L3.11 NOT TO SCALE L3.11 NOT TO SCALE Q <br /> "21 (),1, _1F III <br /> o MI0 Q <br /> Oo W <br /> U CKN 0 <br /> J <br /> o< O <br /> w� <br /> E Ce CI= Q <br /> ZCe iUi U <br /> #3 REBAR STAKE TO MARK SLEEVE Ill w E <br /> (PAINT TOP SAFETY ORANGE) G 1`W Q' <br /> i — <br /> PAVEMENT TITLE <br /> w BACKFILL AS SPECIFIED n DATE DESCRIPTION <br /> z CONTROL WIRE 623/2021 PERMIT <br /> W 1/21/2022 BID ISSUE <br /> 'oQLIJ SCHED.40 P.V.C.SLEEVE <br /> U 2X LINE SIZE <br /> oNOTES: <br /> °EXTEND IRRIGATION SLEEVE 6" <br /> BEYOND EACH SIDE OF PAVING. <br /> MAINLINE OR °DEPTH OF MAINLINE=24". <br /> LATERAL PIPE "DEPTH OF LATERAL @ PAVING=14"MIN. <br /> "DEPTH OF LINES UNDER DRIVING REVISIONS <br /> d SURFACES=24"MIN. MS BS,AL,EH MDC <br /> 2 DRAWN BY CHECK BY <br /> ` Y 7 IRRIGATION TRENCHING UNDER PAVEMENT BID <br /> STATUS <br /> L3.11 NOT TO SCALE <br /> O 1121/2022 <br /> DATE <br /> ROJE P <br /> sp <br /> O PROJECT NUMBER <br /> L3. 11 <br /> It° <br /> Know what's below. <br /> 52021 DTAK,INC. <br /> CCall before you dig. If this drawing is not 24".36-.it has been <br /> d reduced/enlarged.Scale accordingly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.