My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4417 COLBY AVE 2023 Plans 2025-03-18
>
Address Records
>
COLBY AVE
>
4417
>
Plans
>
4417 COLBY AVE 2023 Plans 2025-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 8:40:51 AM
Creation date
3/18/2025 8:40:40 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4417
Permit
B2305-062
Year
2023
Notes
REPLACE EXISTING 453 SQ FT DECK, LIKE FOR LIKE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6/20/23,2:57 PM Chapter 5:Floors,WA Residential Code 2018 I UpCodes <br /> R507.9.2 Deck Lateral Load Connections <br /> Lateral loads shall be transferred to the ground or to a structure capable of transmitting them to the ground.Where the lateral load connection is provided in <br /> accordance with Figure R507.9.2(1),hold-down tension devices shall be installed in not less than two locations per deck,within 24 inches of each end of the <br /> deck.Each device shall have an allowable stress design capacity of not less than 1500 pounds(6672 N).Where the lateral load connections are provided in <br /> accordance with Figure R507.9.2(2),the hold-down tension devices shall be installed in not less than four locations per deck,and each device shall have an <br /> allowable stress design capacity of not less than 750 pounds(3336 N). <br /> Exception:Decks not more than 30 inches above grade at any point may be unattached. <br /> TENsION oEvtcEOR SIMILAR FLOOR SHEATHING NAILING AT <br /> MAXMIUM ON CENTER TO <br /> JOIST WITH HOLPOOWN <br /> rr-F rrrr /isrTr rr� >t�—' <br /> �M►++++ 'to' <br /> 111 <br /> .ir <br /> FLOOR JOIST --DECK JOIST <br /> For SI:1 inch=25.4 mm. <br /> FIGURE R507.9.2(1) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> SHEATHING <br /> NOTE: SIDING <br /> THIS DETAIL IS APPLICABLE <br /> WHERE FLOOR JOISTS AREIII I FLASHING FOR <br /> PARALLEL TO DECK JOISTS. WATER TIGHTNESS <br /> DECKING <br /> 11 - ..r <br /> al ! 7 APPROVED JOIST HANGERS <br /> 2"MIN. 2sc LEDGER WITH FASTENERS <br /> II I IN ACCORDANCE WITH TABLE R507.9.1.3(1) <br /> 'own HOLD-DOWN DEVICE MIN 750 LB.CAPACITY <br /> FLOOR JOISTS ~T� AT 4 LOCATIONS,EVENLY DISTRIBUTED <br /> ALONG DECK AND ONE WITHIN 24"OF EACH <br /> END OF THE LEDGER.HOLD-DOWN DEVICES <br /> SHALL FULLY ENGAGE DECK JOIST PER <br /> HOLD-DOWN MANUFACTURER. <br /> A FULLY THREADED 3/1"DIAMETER LAG <br /> SCREW PREDRILLED WI MIN.3"PENETRATION <br /> TO CENTER OF TOP PLATE,STUDS,OR HEADER. <br /> For SI:1 inch=25.4 mm,1 foot=304.8 mm. <br /> FIGURE R507.9.2(2) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> https://up.codes/viewer-export/washington/wa-residential-code-2018/chapter/5/floors#R507.9.2 1/2 <br />