• <br /> • r i I 2 3 5 <br /> I <br /> General Notes - Floor Plans <br /> A. EXTERIOR DIMENSIONS ARE TO THE OUSIDE FACE OF THE STUDS UNLESS r <br /> O OTHERWISE NOTED. <br /> B. INTERIOR DIMENSIONS ARE TO THE FACE OF STUDS UNLESS OTHERWISE , <br /> NOTED. <br /> C. ALL NON-BEARING WALLS ARE FULL HEIGHT TO UNDERSIDE OF ROOF DECK OR <br /> FLOOR ABVE. <br /> D. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING AS DY K E M A N <br /> REQUIRED AT ALL WALL MOUNTED LAVATORIES,CASEWORK,MIRRORS, <br /> HANDRAILS,ETC.REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND <br /> MECHANICAL DRAWINGS. <br /> E. SEE SHEET A6.01 FOR TYPICAL MOUNTING HEIGHTS FOR WALL MOUNTED ARCHITECTURE + DESIGN <br /> ACCESSORIES AND EQUIPMENT,INCLUDING GRAB BARS. <br /> F. SEE FLOOR FINISH PLANS FOR TRANSITION DETAILS AND THRESHOLDS. <br /> G. CONTRACTOR TO VERIFY ALL ADA CLEARANCE REQUIREMENTS AS NOTED ON ww.dykemon ne: 1]15 West Malmo-me.:i:•.. <br /> SHEETS A6.01 AND A6.02A <br /> H. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS AT FIRE RATED WALLS, .125.259.3161 IT) 2nd Floor!Everett,WA 9820 <br /> INCLUDING BUT NOT LIMITED TO PIPING,DUCTS,CONDUIT,ETC.,WITH <br /> FIRESTOPPING PER I.B.C.REQUIREMENTS.SEE ALSO DETAILS ON DRAWING <br /> A9.10 AND NOTES ON DRAWING CS01 <br /> _ --- <br /> I. SEE NOTES ON DRAWING CS01 FOR INFORMATION ON MODIFICATION TO CONSULTANT: <br /> EXISTING WALLS. <br /> REGISTRATION STAMPS: <br /> 33'-0"/ <br /> X <br /> 2'-9• 2'-9' SEE CSIO FOR NOTES ON MODIFICATIONS TO <br /> /// �p+ EXISTING WALLS.SEE A9.10 FOR FIRESTOPPING <br /> C � WN.4 L�� DETAILS. <br /> I 11 I I C <br /> V //�iaiao'/1//rrii'.e../g%-(/,//��,•// i��/ior/ioiioioaoioi,,, \ <br /> l0 IJ wH W/o 1 0 O , i.,.—I oar <br /> I \ <br /> 'Il J NEW CABINETS,FIXTURES,AND PROJECT IDENTIFICATION: <br /> „— APPLIANCES <br /> iioi�imi / ��m. .n <br /> I <br /> Shoreside Village <br /> el I REF.jrf Renovations <br /> 6 4%rl ( Ja r'�i��/�/%/////O///p//O//%//G o Keynote Legend FOR <br /> /// Key Value Keynote Text <br /> W Unit 832 Williams <br /> 832 Investments <br /> 581 SF / _ AT <br /> • NEW FLOOR FI <br /> THROUGHOUTNISHES j 625 and 701 75th St.SE, <br /> Everett, WA 98203 <br /> , <br /> i/7/9/x o4 A Building Permit Set <br /> B <br /> B <br /> This drawing is: <br /> 1.Copyright 2020 Dykeman,Inc. <br /> 2.The Architect's Instrument of Professional Service. <br /> 3.For use on this project only.Obtain Architect's <br /> written permission for any other use or reproduction. <br />- PROJECT NUMBER: <br /> 2021-035 <br /> REVISIONS: <br /> MARK DATE DESCRIPTION <br /> 3 06/29/2021 Pemat Corrections-6/29/2021 <br /> DUnit#832 <br /> - - <br /> PROJECT TEAM: <br /> PRINCIPAL IN CHARGE:I MS <br /> PROJECT MANAGER: I DH <br /> PROJECT ARCHITECT:I <br /> JOB CAPTAIN: I GM <br /> A <br /> A <br /> DRAWING TITLE: <br /> Unit Plan # 832 <br /> e DRAWING NUMBER: <br /> 0- <br /> 0 2' Al . 1 5 <br /> Scale:1/4•=1'-0' <br /> in <br /> 1 2 I 3 I 4 I 5 <br />