My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6107 BERKSHIRE DR 2021 T MOBILE ANTENNA Plans 2025-03-20
>
Address Records
>
BERKSHIRE DR
>
6107
>
T MOBILE ANTENNA
>
Plans
>
6107 BERKSHIRE DR 2021 T MOBILE ANTENNA Plans 2025-03-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:21:40 AM
Creation date
3/18/2025 9:12:57 AM
Metadata
Fields
Template:
Address Document
Street Name
BERKSHIRE DR
Street Number
6107
Tenant Name
T MOBILE ANTENNA
Permit
B2108-019
Year
2021
Notes
T-MOBILE TO MODIFY EXTG WIRELESS FACILITY W/ NEW ANTENNAS, RADIOS, TMAS, PENDANTS, TRUNKS, CABINETS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r r \ <br /> ‘ ttt, <br /> A WIRE SIZE BURNDY LUG BOLT SIZE <br /> ;� #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT ■ -Mobll T. e • • • <br /> TYPE H8 TYPE 2-YA-2 TYPE XA TYPF YA-2 TYPE GY <br /> #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT <br /> #2 AWG STRANDED YA2C-2TC38 3/8" - 16 NC S 2 BOLT 8960 ALDER\C{)OD ROAD <br /> PORTLAND,OR 97220 <br /> ::1 !:1 'llat <br /> #2/0 AWG STRANDED YA26-2TC38 3/8" - 16 NC S 2 BOLT <br /> II �• `{. #4/0 AWG STRANDED YA28-2N 1/2" - 16 NC S 2 BOLT <br /> TYPE NL TYPE VN TYPE NC TYPE SS TYPE GR BURNDY GROUND LUG W/ 'g' CROWN <br /> HEAT SHRINK <br /> LONG BARREL (CLEAR) <br /> (SEE CHART) CASTLE <br /> . <br /> NUT GROUNDING 1�11i WESTLAKE AVENUE NORTH,SUITE 800 <br /> ra CONDUCTOR <br /> S • LOCK WASHER�„\\y- n• N. SEATTLE,WA 98109 <br /> TYPE VS TYPE VB TYPE PT TYPE GT' !Jr� INI <br /> NOTE l'' <br /> GROUND BAR_' '•� BOLT -p B+T G R P <br /> 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC1717 S.BOULDER <br /> 2. MOLDMOLDS TO BE USED TYPE ONLY TO BER THIS PROJECT.USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. , \ (SEE� )CHAR7) TULSA,OK 74119 <br /> �� BURNDY TWO HOLE LUC W/ PH:(918j587-4630 <br /> LONG BARREL www.btgry,com <br /> -� (SEE CHART) <br /> O CADWELD GROUNDING CONNECTIONS BARE WIRE TO BE <br /> SCALE: NOT TO SCALE <br /> NO-OX AT BOTH ENDS <br /> .-STRANDED (GREEN INSULATED) ONLY FOR #6 AWG T-MOBILE <br /> (SEE CHART) SITE NUMBER: SE01603A <br /> TO ANTENNAS <br /> WEATHERPROOFING KIT ------- <br /> (SEE NOTE 3) (TYPICALLY) / BU#: 823967 <br /> ANTENNA CABLE - ----- 12" TO 24" <br /> t 120" MAX. RX2 T%1/RXI KTATWEATHERPROOFING EVERETT MONOPOLE <br /> ly (TYP) NOTES: 7�T� T i T�j • <br /> • �__ GROUND KIT 1. ALL ALL HARDWARE LUGS BOLTS,ARE TO BE N NUTS, LOCK WASHERD PER S SHALLABEFSTANLESS STEELER'S ALL <br /> 6107 BERKSHIRE DR. <br /> ®®® COAX JUMPER (TYP.)J // (n•P) <br /> /' HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, !1 <br /> FLAT WASHER AND NUT. EVERETT,\V�/A 98203 <br /> #6 AWG STRANDED COPPER GROUND WIRE WEATHERPROOFING KIT <br /> #6 AWG ®SCALE: <br /> MECHANICAL LUG CONNECTION <br /> � I� (TYP. SEE NOTE 2) NOT TO SCALE EXISTING <br /> (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 ---COPPER/GALVANIZED <br /> s' COAX GROUND BAR 127' 0"MONOPOLE <br /> CABLE GROUND KIT -- ! - BONDED DIRECTLY TOWER > <br /> CABLE CONNECTOR -------- - ----- ---------------- -----1 ANTENNA CABLE / #6 AWG MIN. FROM ANTENNA <br /> CABLE GROUND KIT _ <br /> TO BTS EQUIPMENT (TYP.) .yA <br /> NOTES' ISSUED FOR: <br /> 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND < -e v ro w REV DATE DRtS".N DESCRIPTION DFS./QA <br /> WIRE DOWN TO GROUND BAR. <br /> N OTES: .1 5/10/21 YXI PRELIMINARY REVIEW J7S <br /> 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR A 6/22/21 1ID CONSTRUCTION MVP <br /> RECOMMENDED BY CABLE MANUFACTURER. 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND <br /> WIRE DOWN TO ANTENNA GROUND BAR. GROUND BAR ON SHELTER. ICE--\ — , -' -- <br /> 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BRIDGE, OR ON ANTENNA TOWER \ <br /> BE USED. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE <br /> O CABLE GROUND KIT CONNECTION USED. 0 <br /> �OOOo -�0000 3 , <br /> SCALE: NOT TO SCALE O O O • <br /> GROUND CABLE CONNECTION 0 O0000 0000° 0 <br /> 4 <br /> SCALE: NOT TO SCALE —v U <br /> 3/8-11z1"TAMPER 0 O TWO HOLE LUG, OR-- GROUNDING SHALL BE <br /> RESISTANT BOLT EXOTHERMIC WELD TO BE USED — — ELIMINATED WHEN GROUND BAR <br /> ( ) / WITH (j2 AWG BARE CONDUCTOR IS METAL TOWER <br /> ELECTRICALLY BONDED TO <br /> S WIRE TO BUILDING SERVICE <br /> INSULATORS ----_ GROUND OR GROUND RING -" <br /> SEE NOTE(T 2. ___--_ - 4�\,10N kFC <br /> �^P) <br /> �L <br /> WALL BRACKET --- p 0 6 GROUNDWIRE INSTALLATION ° <br /> (TYP) p O NOTE: MINIMUM OF - --- S/S NUT O5 SCALE: NOT TO SCALE <br /> triztfittit <br /> � p 3 THREADS TO BE �, (TYP) <br /> ;� <br /> p VISIBLE /, r```���••,..�\\ <br /> O O (TYP) <br /> II <br /> O O O \ i ;__ S/5 SPLIT Y/21 <br /> WASHER <br /> O O 2 HOLE LONG (TYP) #2 TINNED SOLID IN 3/4" LIQUID TIGHT ---� -- PIPE <br /> BARREL TINNED <br /> �� ® 0 ---- UNIVERSAL COPPER SOLID COPPER CONDUIT FROM 24" BELOW GRADE TO �� <br /> / O GROUND BAR (4"x20") LUG N S/S FLAT WITHIN 3" TO 6" OF CAD-WELD <br /> / WASHER TERMINATION POINT. EXPOSED END OF L N� L <br /> LOCK WASHER !�;�\ (TYP) �•I• t�'■, . �j (TYP) THE LIQUID TIGHT CONDUIT MUST BE I\_a HUH <br /> P N MI0 ����= SEALED WITH SILICONE CAULK. <br /> (TYP) VI �i�_•1•� I II _II <br /> ` TWO-HOLE <br /> COMPRESSION LUG TIN COATED SOLID CADWELD -- fir— IIIIII B&T ENGINEERING, INC. <br /> NOTES: COPPER BUS BAR S/S FLAT (TYP) \ �-rIi l =II 3425 <br /> W <br /> im <br /> es <br /> CHERRY INSULATOR -.._._-_ (ASTER 1 (IIIIr- <br /> USAII lSIESST'IIItLA ONOELAWFOR 1 <br /> 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE BQI TO BE INSTALLED ON CROWN CASTLE _ TYP <br /> INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY OAS-STD-10091. NO \ I II'IS,St VIOLATION OE Ll\\'POR:1NY PERSON, <br /> INSTALLED IF REQUIRED E� .R TI II:DIRICFI//\ <br /> MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, S/S BOLT TIE INTO EXISTING GROUND RING _ IIIIIIU I/I:A LICENSED PBI'I IlSSIONAL ENOINITR, <br /> CAD-WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. — (TYP) n To 1CI'P.0 TI II',Urn:G/,II\'I'. <br /> 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL IIcIIIIII=IIIIII <br /> USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. SHEET NUMBER: , REVISION: , <br /> OO SCO E GRUNO OBAR DETAIL O SCALE O LUG DE NOT TO SCALE ®SCANSIONG E:IT OTINTO SCALE <br /> DETAIL G- 2 O <br /> J - J <br />
The URL can be used to link to this page
Your browser does not support the video tag.