1931 W MUKILTEO BLVD 2021 T MOBILE ANTENNA Plans 2025-03-20
>
Address Records
>
W MUKILTEO BLVD
>
1931
>
T MOBILE ANTENNA
>
Plans
>
1931 W MUKILTEO BLVD 2021 T MOBILE ANTENNA Plans 2025-03-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:51:43 AM
Creation date
3/18/2025 9:45:53 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
1931
Tenant Name
T MOBILE ANTENNA
Permit
B2108-016
Year
2021
Notes
REPLACE (2) ANTENNAS AND REMOVE/ADD/REPLACE ANCILLARY EQUIPMENT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br /> SYMBOL DESCRIPTION <br /> KEY NOTES: <br /> 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS.ACTUAL INSTALLATION AND GROUND ROD NOTES: <br /> ® COPPER GROUND ROD CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 01 CADWELD (TYP.) SEE SHEET E-2. _O SII�'I <br /> ❑ ❑ ❑ ❑ \V{ ,OkRe❑ <br /> 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC 1. ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE ANTENNA GROUND BAR AT ANTENNA LEVEL OF POLE TIED V <br /> ® CADWELD COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED THE GROUND SYSTEM HAS BEEN INSTALLED;A QUALIFIED INDIVIDUAL, UTILIZING O INTO TOWER GROUND BAR AT BASE OF POLE(V.I.F.)SEE <br /> BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. 111E REPORT SHEET E-2. <br /> GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST <br /> ® EXOTHERMIC WELD FROM TOWER OR POLE USING MFR'S PRACTICES. POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU. 3 EQUIPMENT GROUND BAR TIED INTO SHELTER HALO OR <br /> EXTERIOR GROUND RING (V.I.F.)SEE SHEET E-2. <br /> 3. ALL GROUND CONNECTIONS SHALL BE CADWELD.ALL WIRES SHALL BE 2. POINT GROUND TEST OR 3 POINT 62%TESTS WILL NOT BE ACCEPTED AS <br /> ►:I TEST WELL COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE ® #6 AWG JUNCTION BOX GROUND TO EQUIPMENT GROUND <br /> ABOVE GROUND. GRIDS AND EXISTINGIEE COMMUNICATIONS S FACILITY.ISOLATED FROM THE A/C SYSTEM BAR (TYP). SEE SHEET E-2. , NN <br /> GROUND BAR 4. CONTRACTOR TO VERIFY AND TEST GROUND SOURCE, GROUNDING AND OTHER O #6 AWG EQUIPMENT RACK GROUND TO EQUIPMENT GROUND <br /> OPERATIONAL TESTING WILL BE WITNESSED BY CARRIER, REPRESENTATIVE. BAR (TYP). SEE SHEET E-2. <br /> /""'"""""N GROUND WIRE 5. REFERM Y WITH GENERAL ELECTRIC; D ELECTRICALANDA PROVISION O Glotel. <br /> AND COMPLY WITH ALL REQUIREMENTS OF GROUNDINGENELSTANDARDS. 6 6 AWG ANTENNA MOUNT GROUND TO ANTENNA GROUND BAR <br /> TYP). SEE SHEET E-2. <br /> ---- #2 AWG GROUND RING 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING 7 #6 AWG RRH/PENDANT MOUNT GROUND TO ANTENNA + } J <br /> STSILM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED CARRIER, O GROUND BAR (TYP). SEE SHEET E-2. >Integrity DeIiveredTM <br /> REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING STSItM. PHOTO <br /> FIELD VERIFY& TIE INTO DOCUMENT ALL CADWELDS AND GROUND RINGS. #2 AWG PPC GROUND TIED INTO EXISTING GROUNDING <br /> EXISTING GROUNDING Sr.IEM © SYSTEM (V.I.F.) SEE SHEET E-2. <br /> 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTAWNG <br /> GROUNDING STSI tM DUE TO SITE SOIL CONDITIONS. 6 AWG LEC ROUTER GROUND TO EQUIPMENT GROUND BAR <br /> 8. USE PANI SCHEME FOR LOADING GROUNDS ON MOB AS DISCUSSED IN NSTD O9 TYP). SEE SHEET E-2. <br /> w <br /> r 119, 33 & 36. 1 <br /> ni 10 #2 AWG GENPLUG GROUND TIED INTO EXISTING GROUNDING REDS VERSION 7 <br /> STSIEM (V.I.F.) SEE SHEET E-2. <br /> 0 <br /> a <br /> r NOTE: <br /> chi GROUND HYBRID CABLES TOP& BOTTOM USING <br /> P UNIVERSAL 1-5/8"GROUNDING STRAP, PART#252172 <br /> N CHASE/ <br /> v SNO-PUD/ <br /> 0 <br /> SE01689A <br /> w <br /> 5 1931 W MUKILTEO BLVD <br /> re EVERETT,WA 98203 <br /> e SNOHOMISH COUNTY <br /> 3 ---1 / <br /> a — / <br /> O `A� �S- \\ 06-10-2021 <br /> TYP. ; .: <br /> ix TYP. wi4t1; 4 t � Ni �N <br /> � MAD <br /> qNe 1 ' \ <br /> \ � ofwasH / ilk <br /> \ <br /> \ _ _ / a z <br /> O \ \ O \ \\ \ ' <br /> o \ \\�' ;TIP. \\\ \ , I�,,� '` <br /> "A A * \ <br /> a ANTENNA PLAN \ \�AM& <br /> \ `Di�`,'F('I STE" <br /> f75'-5"AGL RAD CENTER 0 \ G\ <br /> z \ \� O\ SiONAL E�z \ID \\ \r'r <br /> / \� . \ ` EXPIRES 01-09 2022 J <br /> \4 cc REVISIONS <br /> 0_ REV. DATE DESCRIPTION BY <br /> K <br /> d TYPO \1\•\\\ <br /> © © \ R OS/1)/21 ISSUED FOR 90.[CO REVIEW OF <br /> o_ i� \ 0 06/09/21 ISSUED FOR 100R CONSTRUCTION RW <br /> 7F. \g © I/jam <br /> �lttj% O�' \ \\ <br /> •��I <br /> K �%`\ <br /> f., ��\ \ TITLE <br /> (1, / SCHEMATIC GROUNDING PLANS J <br /> z <br /> w SHEET <br /> z <br /> [ <br /> RRH PLAN <br /> o ±62'-5"AGL MOUNT HEIGHT <br /> E- 1 O N N <br /> 5 % <br /> TRU !�, <br /> z E NORTH TRUE NORTH <br /> 24"x36"SCALE: 3/4" = 1'-0" IMIIIIIIANTENNA SCHEMATIC GROUNDING PLAN 2 24"x36" SCALE: 1/2" = 1'-0" 1 11"x17" SCALE: 1/4" = 1'-0" , EQUIPMENT SCHEMATIC GROUNDING PLAN (GLOTEL PROJECT S. J656) <br /> �1"z17"SCALE: 3/8" = 1'-0" 1' 6" 0" 1' 2' 1' 0" 2' _ __ <br />