My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2501 HOYT AVE 2023 Plans 2025-03-18
>
Address Records
>
HOYT AVE
>
2501
>
Plans
>
2501 HOYT AVE 2023 Plans 2025-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 10:21:27 AM
Creation date
3/18/2025 10:21:20 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2501
Permit
B2306-025
Year
2023
Notes
DEMO EXISTING ROOF TO CONCRETE DECK, ADD NEW ROOF/INSULATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br /> w 1. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO <br /> All CONSTRUCTION. NW <br /> ROFESSIONAL <br /> 2. APPROVED MANUFACTURERS FOR THIS PROJECT ARE CARLISLE AND OOFING <br /> DURMAST. RVICES <br /> 40Typ. 34 5 3 PLUMBNG,AAND ELAECTR CALIN INCLUDING MASONRY,sraucTURAL, ORPORATED <br /> A • 4. THE NEW ROOF SLOPE FOR ALL ROOF AREAS SHALL BE A MINIMUM OF 1729 208th ST SE <br /> THE <br /> 5. ALL PRE-FINISHED SHEET METAL FLASHINGS ARE TO BE FORMED IN <br /> I / 1 I MAXIMUM OF 10'0"SECTIONS. Suite 205 <br /> 6. INSULATION AND PLYWOOD WALKWAYS ARE TO BE INSTALLED OVER <br /> A5 Typ. A18 <br /> A4 NEW <br /> MEMBRANE FOR TRANSPORTATION OF MATERIALS AND/OR Bothell, WA 98012 <br /> Typ• \1" 1)/ <br /> I DEBRIS. <br /> 7. USE UNTREATED DF WOOD BLOCKING AS NEEDED TO RAISE THE Phone: 425.280.7180 <br /> l HEIGHT OF THE CANOPY ROOF PERIMETER WALLS SO THAT THEY ARE <br /> E} 1 / FLUSH WITH THE NEW ROOF SYSTEM. <br /> Q f F THE <br /> N ORTH/VVEST ! A8 T 8 EXISTING VENTS TO CREATE A MINUSE UNTREATED DF WOOD IIMUM FLASHING HEIGHT ONG TO RAISE THE HEIGHT F 8"ABOVE <br /> CANOPROOFS O s yp THE FIELD OF THE NEW ROOF. <br /> YR 9. RAISE PIPES AS NEEDED TO CREATE A MINIMUM FLASHING HEIGHT OF <br /> \ 8"ABOVE THE FIELD OF THE NEW ROOF. <br /> 10. INSTALL NEW POST METAL WHERE REMOVED PER DETAIL 5/A-2.0.POST <br /> A7 j' , ® DIMENSIONS ARE 9"WIDE AND 10"HIGH FROM THE COPING. <br /> Yp' ❑ Al �� 11. SMALL PENETRATIONS(PIPE/CONDUIT)NOT SHOWN.FLASH PER DETAIL r <br /> 17/A-2.2 O <br /> A11 Typ. O 12. WELD ROOF MEMBRANE PER DETAIL 18/A-2.2 Q <br /> A2 I I A13 e 13. A MECHANICAL CURB ENVELOPE FLASHING DETAIL IS AUTHORIZED 0 1 (V <br /> \ / O ® ONLY IF THE CURB FLASHING HEIGHT IS A MINIMUM OF 5"ABOVE THEO ^+ W <br /> vIn I I I HEIGHT OF THE NEW ROOF SYSTEM AND THE DETAIL IS APPROVED BY I O W\ 0) <br /> TOWER A8 Tarp. S SGl THE MANUFACTURER. REFERENCE DETAIL 19/A-2.2 0 < <br /> oc '14 a <br /> ROOF A6 ��'�t FY u► >, a' 0 <br /> ARCHITECTURAL FLAG NOTES <br /> A4 /Typ\ [1 A UeR4 S i2-3 S Al ANDNEW ROOF ASSEMBLY CANOPY ROOFS)-60 MIIL SINGLE-PLY ROOFCAL OF THE MAIN OOF 0 CU 0 I <br /> \ VAL�c r4/ MEMBRANE SET IN ADHESIVE,1/4"DENSD CK OR `V CU �1) <br /> A3T Typ'\ MAIN ROOF yJV SECUROCKCOVERBOARDSETI t SI -- DPOL 1 �V L <br /> IN <br /> EINSOFS • (AVERAGE'DO£R-38) V ^ <br /> IN ADHESIVE TWO PLIES OF S, "OTH TORCH � L c CI Q <br /> -RIMER,OVER A ' •` -ET -•=- • c <br /> REFERENCE DETAIL 3/A-2.0 O U) Id- LU <br /> Al i f Al NEW TOWER ROOF ASSEMBLY-60 MIL SINGLE-PLY CV <br /> ROOF MEMBRANE SET IN ADHESIVE,1/4"DENSDECK OR <br /> \ SECUROCK COVER BOARD SET IN ADHESIVE,TAPERED <br /> A3 Typ. POLYISOCYANURATE INSULATION(AVERAGE R-38)SET Revisions: <br /> IN ADHESIVE,TWO PLIES OF SELF-ADHERED ROOF <br /> MEMBRANE,MECHANICALLY FASTENED 1/4"DENSDECK <br /> OR SECUROCK COVER BOARD,OVER A FLUTED METAL <br /> Ai ROOF DECK.REFERENCE DETAIL 4/A-2.0 None <br /> Al2 Typ. A5 Typ. A3 INSTALL NEW WALL FLASHING.ROOF MEMBRANE TO <br /> EXTEND UP AND OVER EACH POST WHERE APPLICABLE. <br /> REFERENCE DETAIL 5/A-2.0 <br /> C -__. ------,.. A9 0 Azi> COLUMN ROOF-TO-WALL FLASHING CONDITION AT <br /> \ MARBLE CRETE.CHIP AWAY EXISTING ROCK TO CREATE <br /> ASTyp. A SMOOTH SURFACE(FROM THE ELEVATION OF THE <br /> / NEW ROOF TO 10"ABOVE THE ROOF).ADHERE ROOF <br /> A9 MEMBRANE TO WALL AND SECURE WITH TERM BAR. Design: JDY <br /> SAW CUT NEW LINE IN MARBLE CRETE WALL.NOTE: <br /> � ( NEW SAW LINE TO BE A MINIMUM OF 8"ABOVE THE Drawn: J M Y <br /> f C47 , [ FIELD OF THE NEW ROOF.INSTALL NEW TWO PIECE 24- <br /> ® GAUGE KYNAR FINISHED RECESSED REGLET WITH A {� <br /> SOUTH CANOPY ROOF ! Q / 3/4"HEMMED DRIP EDGE OVER THE AFFECTED AREA. Checked: JDY <br /> A4 Tyr= ABTyp. i FASTEN AT 24"O.C.REFERENCE DETAIL 6/A-2.0 <br /> Al A5 INSTALL NEW 24-GAUGE KYNAR FINISH STANDING SEAM <br /> ® 16 Typ. SHEET METAL COPING WITH A 3/4"HEMMED DRIP EDGE. <br /> �� / EXTERIOR LEG TO EXTEND DOWN TO MATCH THE Job Number: <br /> A3Typ. Al2Typ. ELEVATOR <br /> LEG TO(EXTEND DOWN 4 INCH S..FASTEN CONTINUOUSON OF THE OLD COPING AND THE I <br /> �O / CLIP TO EXTERIOR WALL AT 12"ON CENTER. 23-604 <br /> \ CONTINUOS CLIP TO BE 22-GAUGE SHEET METAL,6" <br /> A5 Typ" WIDE WITH.A 3/4"LIP. FASTEN INSIDE LEG WITH <br /> GROMMETED FASTENERS AT 24"ON CENTER. POP <br /> A15 Typ. A 14 T RIVET INSIDE AND OUTSIDE LEG OF COPING AT ALL I ss`u e. <br /> YP CORNERS.NOTE:METAL TO EXTEND UP AND OVER ALL ^ <br /> I ! POSTS.REFERENCE DETAIL 7/A-2.1 2 <br /> I Architectural Drawings 4/L 5/ 02 FLASH VENT CURB FLASHING 3 <br /> D _.1. 1/8 =1_0. _..._ ..._... 1 - - - A6 TYPICAL AT ALL SIMILAR CONDIT DETAIL 8/A-2.1. <br /> S. <br /> A7 INSTALL NEW CURB TO EXISTING SPOTLIGHTS PER Drawing Title. <br /> DETAIL 8/A-2.1.TYPICAL OF TWO SPOTLIGHTS ON THE <br /> ARCHITECTURAL FLAG NOTES CONT MAIN ROOF AND ONE SPOTLIGHT ON THE WEST <br /> CANOPY ROOF. <br /> Al2> INSTALL GUARDIAN CB-12 ROOF ANCHORS PER A17> INSTALL NEW ROOF HATCH IN THE TOWER ROOF. Architectural <br /> MANUFACTURER'S INSTALLATION REQUIREMENTS. / PROVIDE SUPPLEMENTAL FRAMING AS NEEDED. A8 FLASH PRIMARY DRAINS PER DETAIL 9/A-2.1.REPLACE <br /> TYPICAL AT ALL SIMILAR CONDITIONS. FLASH ROOF HATCH PER DETAILI3/A-2.1 EXISTING DRAIN COVER WITH NEW CAST IRON DRAIN <br /> REFERENCE DETAIL 12/A-2.1 COVER.TYPICAL AT ALL SIMILAR CONDITIONS. D raW I n g S <br /> A18> ROOF-TO-WALL CONDITION-IN BETWEEN COLUMNS <br /> A13> FLASH EXISTING ROOF HATCH PER DETAIL 13/A-2.1 / WHERE STONES ARE EMBEDDED IN THE CONCRETE A9 FLASH EXISTING PRIMARY SCUPPER.INSTALL NEW <br /> WALL:CHIP AWAY STONES TO CREATE A SMOOTH THRU-WALL COLLECTOR BOX AND 24-GAUGE SHEET <br /> \ SURFACE(FROM THE ELEVATION OF THE ROOF TO METAL DOWNSPOUT.PER DETAIL 10/A-2.1 <br /> A14> INSTALL NEW ROOF-TO-WALL FLASHING.TYPICAL OF 10"ABOVE THE SURFACE OF THE NEW ROOF),THEN FOR THE PRIMARY SCUPPER ON THE SOUTH EAST <br /> THE SOUTH WALL OF THE SOUTH CANOPY ROOF. EXTEND WALL FLASHING 8"ABOVE THE SURFACE OF � _ CORNER OF THE MAIN ROOF.RE ROUTE DOWNSPOUT <br /> REFERENCE DETAIL 14/A-2.2 THE NEW ROOF AND CHLORIDE ROOF MEMBRANE DTO WALL AND SECUREHERE POLYVINYL <br /> F; �� SO THAT IT NO LONGER DRAINS ONTO THE SOUTH Drawing Number: <br /> CANOPY A <br /> - GLASS BLOCK PANEL ON THE SOUTH CANOPY ROOF. POLYVINYL INSTALL NEW ROOF-TO-WALL FLASHING TO THE WITH CHLORIDE ROOF MEMBR BAR.COVER TOP ANE WINOUS TH E OF REVIEWED p> BLOCK NOT ROOF. <br /> / REFERENCE DETAIL 15/A-2.2 LIQUID-APPLIED PMMA FLASHING.INSTALL A <br /> SURFACE-MOUNTED REGLET PER DETAIL 6/A-2.0 <br /> A16> INSTALL NEW DOUBLE-DOME SAFETY RATED Al 1> INSTALL NEW THRU-WALL EMERGENCY OVERFLOW A-1 •0 <br /> SKYLIGHTS WHERE REMOVED. / SCUPPER PER DETAIL 11/A-2.1 • <br /> REFERENCE DETAIL 16/A-2.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.