<br /> PROPOSED AT&T 42"0x9'-4"TALL ' —
<br /> FRP CANISTER(1 PER SECTOR. 3 O
<br /> PROPOSED ANTENNA CONFIGURATION AND SCHEDULE RFDS V2.00 DATED 02/21/23 RELOCATED AT&T DC2 TOTAL) (PERSTRUCRTRAL) `�
<br /> NUMBER OF ANTENNA NUMBER FEEDER RRH DISTRIBUTION UNIT (1 TOTAL) PROPOSED AT&T LTE 700/LTE 1900/�©© -_7 a
<br /> POSITION ALPHA AZIMUTH RAD CENTER NUMBEDMANUFACTURER MODEL OF FEEDER FEEDER 0 LENGTH SURGE SUPPRESSION UNIT RRU MODELLOCATION LTE AWS/5G AWS PANEL ANTENNA
<br /> 5G 850 RRH 4T4R B5 160W AHCA TOP PROPOSED AT&T (1 PER SECTOR, 3'TOTAL) VZ,VgYVgg
<br /> (2) 8/6 POWER
<br /> 1 90' t116.-0" 1 KATHREIN 80010966 121'-0" --....'"'n Mobility
<br /> LIE WCS TRUNKS RRH4X25-WCS-4R TOP AEQK ACTNE ANTENNA/RADIO
<br /> LW 700 RRH 4T4R B12/14/29 TOP
<br /> (1 PER SECTOR, 3 TOTAL) PROPOSED AT&T DC8 O
<br /> (E) (1) FC12-PC6-10E DISTRIBUTION UNIT EXISTING AT&T 0C2
<br /> 370W AHLBBA �� MOUNTED ON UNISTRUT DISTRIBUTION UNIT
<br /> 3 LIE A• A1S 90' t116'-0" 1 COMMSCOPE NNH4-65C-R6-HG (1) FIBER TRUNK 121'-0" (E) (3) DC2-48-60-0-9E 825 RRH4X30-4R TOP
<br /> (1 PER SECTOR, 3 TOTAL) (2 TOTAL)TO REMAIN
<br /> CEXISTING BUILDING
<br /> IE 1900/
<br /> 1• 9 0/ (P) (1) DC6-48-60-18
<br /> B66A RRH4X45-4R TOP
<br /> L PARAPET WALL (TYP) RYKA-=''=CONSULTING.
<br /> (P) (1) 6/6 POWER INTEGRATED WITHIN MMAT./.‘
<br /> �^ �
<br /> 4 5G CBAND 90' ±118'-3" 1 NOKIA AEQK TRUNK 121'-0" 64T64R 192AE n77 TOPAir
<br /> (P) (1) FIBER TRUNK 200W r;; EXISTING AT&T LTE WCS/ 5628 AIRPORT WAY
<br /> NUMBER OF ANTENNA NUMBER FEEDER RRH >r 5G 850 PANEL ANTENNA
<br /> POSITION BETA AZIMUTH MD CENTER ANTENNA MANUFACTURER MODEL FEEDER FEEDER 0 LENGTH SURGE SUPPRESSION UNIT RRU MODEL LOCATION t (1 PER SECTOR, 3 TOTAL) SOUTH, SUITE 330
<br /> TO 3 5G 850 225' t116'-0" 1 KATHREIN 80010966 (2) 8/6 POWERRRH 4T4R 85 160W AHCA TOP REMAIN SEATTLE, WA 981 08
<br /> LIE WCS TRUNKS RRH4X25-WCS-4R TOP �,�r
<br /> 121.-0" PER j AMMIIr - EXISTING AT&T 36"0 FRP
<br /> LTE 700 RRH 4T4R 812/14/29 TOP � 1 _ BUILDING
<br /> DING � CANISTER AND FRAME
<br /> (E) (1) FC12-PC6-1OE _ IIP. _ (1 THIS SECTOR,
<br /> 370W AHLBBA ROOFTOP I 2 TOTAL)TO REMAIN
<br /> 4 LIE AWS/NNS 225' t116'-0" 1 COMMSCOPE NNH4-65C-R6-HG (1) FIBER TRUNKS 121'-0" (E) (3) DC2-48-60-0-9E B25 RRH4X30-4R TOP ` `. • ' -"' . RFDS V2.00 DATED:02/21/2023
<br /> RELOCATED LTE 1900/ (P) (1) DC6-48-60-18 B66A RRH4X45-4R TOP I ,I ' RRRH ITM0 NTED EON WCS
<br /> SG 1900 1 UNISTRUT
<br /> (P) (1) 6/6 POWER INTEGRATED WITHIN MMA — ° _(1 PER SECTOR, 3 TOTAL)
<br /> 5 50 CBAND 225' t122'-3" 1 NOKIA AEQK TRUNK 121'-0" 64T64R 192AE n77 TOP •'—' -I - °° �� WA6 2 9 9
<br /> (P) (1) POWER TRUNK 200W ° RELOCATED AT&T SG 850
<br /> NUMBER OF ANTENNA NUMBER FEEDER RRH /
<br /> POSITION GAMMA AZIMUTH RAD CENTER ANTENNA MANUFACTURER MODEL OF FEEDER FEEDER / LENGTH SURGE SUPPRESSION UNIT RRU YODEL LOCATION // RRH UNIT (1 PER
<br /> (P) (1) 6/6 POWER INTEGRATED WITHIN MMA \ /,// \—EXISTING AT&T ROOFTOP PROPOSED AT&T LTE 700 ��D ON UNISTRUT PORT GAR D N E R
<br /> 1 5G CBAND 340' ±118.-3" 1 NOKIA AEQK TRUNK 121'-0" 64T64R 192AE n77 TOP CABLE TRAY RRH UNIT MOUNTED ON
<br /> (P) (1) FIBER TRUNK 200W UNISTRUT EXISTING AT&T (2) FIBER
<br /> LIE 700 RRH 4T4R B12/14/29 TOP EXISTING AT&T 36"0 FRP (1 PER SECTOR, 3 TOTAL) & (4) POWER TRUNKS
<br /> (E) (1) FC12-PC6-10E 370W AHLBBA CANISTER (2 PER SECTOR, 5 TO REMAIN
<br /> 3 LTE AWS/ 340' 3116'-0" 1 COMMSCOPE NNH4-65C-R6-HG (1) FIBER TRUNK 121'-0" (E) (3) DC2-48-60-0-9E B25 RRH4X30-4R TOP 6 TOTAL) TO REMAIN e
<br /> 5G AWS PROPOSED AT&T(3) FIBER
<br /> L (P) (1) DC6-48-60-18 B66A RRH4X45-4R TOP RELOCATED AT&T DC2 &(3) POWER TRUNKS
<br /> 5G 1900 DISTRIBUTION UNIT (1 TOTAL)
<br /> 5G 850 (2) 8/6 POWERRRH 4T4R BS 160W AHCA TOP RELOCATED AT&T LTE AWS RRH N
<br /> 4 340' tt 16'-0" 1 KATHREIN 80010966 TRUNKS 121'-0"
<br /> LTE WCS RRH4X25-WCS-4R TOP UNIT MOUNTED ON UNISTRUT 1321 COLBY AVENUE
<br /> (1 PER SECTOR, 3 TOTAL) JO�! EVERETT,WA 98201
<br /> RELOCATED AT&T LTE 1900 RRH SNOHOMISH COUNTY
<br /> �
<br /> UNIT MOUNTED ON UNISTRUT IV
<br /> (1 PER SECTOR, 3 TOTAL)
<br /> TRL.E\'ORTH
<br /> 24"x36" SCALE: N.T.S. 24•'x36" SCALE: 3/8" = 1'-0" REVISIONS
<br /> 11"x17"SCALE: N.T.S. PROPOSED ANTENNA SCHEDULE 4 11•'x1r SCALE: 3/,6" = ,'_D r� 2'
<br /> PROPOSED ANTENNA CONFIGURATION (GAMMA SECTOR) DRAWN BY CHECKED PPPROVEO—I.
<br /> RLD NJL RM
<br /> REV. DATE DESCRIPTION BY
<br /> A 12/22/22 ISSUED FOR 90%CD RENEW RLD
<br /> RELOCATED AT&T LTE 1900 RRH RELOCATED AT&T 5G 850 RRH 0 02/13/23 ISSUED FOR 100%CONSTRUCTION SL
<br /> UNIT MOUNTED ON UNISTRUT UNIT (1 PER SECTOR, 3 TOTAL) 1 03/06/23 ISSUED FOR 100%CD REVIEW OLD ,
<br /> (1 PER SECTOR, 3 TOTAL) -- MOUNTED ON UNISTRUT 1 RELOCATED AT&T LTE WCS/SG 850
<br /> EXISTING A7&T DC2 DISTRIBUTION 2 04/19/23 ISSUED FOR 100%CONSTRUCTION RLD
<br /> RELOCATED AT&T LTE AWS RRH I UNIT (2 TOTAL)TO REMAIN PANEL ANTENNA
<br /> UNIT MOUNTED ON UNISTRUT II EXISTING AT&T DC2 DISTRIBUTION P(Ai
<br /> PER SECTOR, 3 TOTAL)
<br /> PROPOSED AT&T DCB UNIT (2 TOTAL)TO REMAIN
<br /> (1 PER SECTOR, 3 TOTAL) 1 DISTRIER1110N UNR e6
<br /> MOUNTED ON UNISTRUT 6 RELOCATED AT&T LTE WCS RRH
<br /> PROPOSED (1 PER SECTOR, 3 TOTAL) UNIT MOUNTED ON UNISTRUT ALPHA \
<br /> 6"TALL FRP I I\\ (1 PER SECTOR, 3 TOTAL) o •4211x12.- �� AZ. 90' /
<br /> CANISTER (1 PER SECTOR, 4._I I \\ PROPOSED AT&T LTE 700 RRFiO -1'r o
<br /> 3 TOTAL) (PER STRUCNRAL) ) \\\ UNIT MOUNTED ON UNISTRUT EXISTING AT&T ROOFTOP 04-26-2023
<br /> \ (1 PER SECTOR' 3 TOTAL) EXISTING AT&T CABLE TRAY - EXISTING AT&T 36"0 FRP CANISTER
<br /> B \\\ ROOFTOP CABLE TRAY RELOCATED AT&T DC2 PERR NN SECTOR, 6 TOTAL) �,^
<br /> 41. \\\ DISTRIBUTION UNIT (1 TOTAL) _,. \V1 C D q ^'
<br /> PROPOSED AT&T LIE -, \\\ PROPOSED AT&T(3) FIBER �P F WAS //I// iiiil
<br /> 700/L7E 1900/ \ &(3) POWER'TRUNKS RELOCATED AT&T LTE 1900 RRH
<br /> LIE AWS/5G AWS PANEL 6....N1N110,A \ UNIT MOUNTED ONUNISTRUT (` HANTENNA \\ EXISTING AT&T (2) FIBER (1 PER SECTOR, 3 TOTAL) -----......____________I It x _ .? G'(1 PER SECTOR. 3 TOTAL) \\\\ / & (4) POWER TRUNKS TO PROPOSED AT&T LTE 700/LTE 1900/©© �Q' _
<br /> ©©0 / \\\• / \ UNIIT MM REMAIN ONTED ON TE UNSTRUS RRH (� (1EPER/5G Avis PANEL SECTOR. 3 TOTAI�M'RENNA WV, V CQ y '/:, Z
<br /> �V�V� II
<br /> / ZZZ � (1 PER SECTOR, 3 TOTAL) _�/ i/ ��yy I , '
<br /> L \ MOUNTED
<br /> AT&T SG�85p RRH PROPOSED AT&T DCB y CITY O F E Y E S A ET 6 , ,..i�' 4
<br /> IN
<br /> \ UNIT (1 PER SECTOR, 3 TOTAL) �r� �VEif
<br /> UPPER DISTRIBUTION UNIT '
<br /> PROPOSED AT&T BUILDING MOUNTED ON UNISTRUT = V I EW E D F O R P E R M L
<br /> AEON ACTIVE ROOFTOP7 _- ° (1 PER SECTOR, 3 TOTAL)- YII(.�(i 0•31 O
<br /> ANTENNA/RADIO (STACKED) ■E �� RELOCATED AT&T LTE WCS ,� S T E" \�
<br /> (1 PER SECTOR, 3 TOTAL) RRH UNIT MOUNTED ON OUNRMWD AT&TUM700`H ���---111 PROPOSED AT&T 42'r%9'-4'TALL S/ ENG
<br /> UNISTRUT FRP CANISTER(i PER StA.IUK. 3 O ONAL
<br /> �� 1 `i' (1 PER SECTOR, 3 TOTAL) (i PER SECTOR' 3 TOTAL) TOTAL) (� �
<br /> /l
<br /> EXISTING TOTAL)AT&T DC2 DISTRIBUTION PROPOSED AT&T(3) FIBER �� f UPPER EXPIRES 01-09-2025
<br /> RAL)
<br /> UNIT (1 TO REMAIN & (3)POWER TRUNKS // BUILDING
<br /> EXISTING ROOFTOP ROOFTOP
<br /> ACCESS HATCH p RELOCATED AT&T LTE EXISTING AT&T (2) FIBER & /j/ PROPOSED AT&T TITLE
<br /> ��ryryh WCS/5G 850 PANEL ANTENNA (4) POWER TRUNKS TO REMAIN // �� PROPOSED ANTENNA
<br /> // AEQK ACTNE ANTENNA/BATIK)
<br /> EXISTING BUILDING / p•4' • (1 PER SECTOR, 3 TOTAL) // (1 PER SECTOR, 3 TOTAL) �� CONFIGURATIONS&SCHEDULE
<br /> PARAPET WALL (TYP) /
<br /> EXISTING AT&T DC2 // EXISTING AT&T 36"0 FRP CANISTER - -
<br /> DISTRIBUTION UNIT /// (2 PER SECTOR, 6 TOTAL) SHEET
<br /> (2 TOTAL)TO REMAIN // , TO REMAIN
<br /> EXISTING AT&T VACANT 24"0 FRP EXISTING AT&T 36"0 FRP CANISTER /// A-5
<br /> CANISTER (1 PER SECTOR, 3 TOTAL) (2 PER SECTOR, 6 TOTAL) N // N
<br /> TO REMAIN TO REMAIN // (•' ALPHA
<br /> / AZ:90'
<br /> ' .r 4S1T !--------7)4; IIII` PROPRIETARY INFORMATION:
<br /> NG BUILDING i� THE INFORMATION CONTAINED IN THIS SET OF
<br /> PARAPET WALL (NP)
<br /> TRUE1oRTH TRDE':oRTH CONSTRUCTION DOCUMENTS IS PROPRIETARY BY
<br /> NATURE. ANY USE OR DISCLOSURE OTHER
<br /> 24"x36" SCALE: 3/8" = 1•-0" 24"x36" SCALE: 3/8" = 1'-0" THAN THAT WHICH RELATES TO AT&T MOBIUTY
<br /> „'x,T SCALE: 3/,6" = ,'-o" rmom mmommomm I' 0' 2 PROPOSED ANTENNA CONFIGURATION (BETA SECTOR) 2 ,1"x17" SCALE: 33/8" = 1'-0" 2®, PROPOSED ANTENNA CONFIGURATION (ALPHA SECTOR) 1 SERVICES IS STRICTLY PROHIBITED.
<br />
|