Laserfiche WebLink
NOTE: <br /> 1. ONLY PROPOSED AT&T ANTENNA <br /> CONFIGURATION IS SHOWN IN PLAN VIEW PROPOSED AT&T FRP PROPOSED AT&T FRP _ <br /> FOR CLARITY. CANISTER WI PROPOSED CANISTER W/PROPOSED <br /> 2. RF WARNING SIGNS AND BARRIERS TO BE ANTENNA & EXISTING ANTENNA& EXISTING © ,v, a t&t <br /> INSTALLED IN ACCORDANCE WITH RE REPORT. ASSOCIATED EQUIPMENT ASSOCIATED EQUIPMENT WY EXISTING BLOCK <br /> \\—% <br /> SEE SHEET A-9 FOR SIGN DETAILS. SCREEN WALL(TYP) <br /> Mobility� <br /> �oWER BUILDING <br /> ROOFTOP \ <br /> I I I RELOCATED AT&T ANTENNA <br /> WITHIN EXISTING FRP CANISTER <br /> I _ W/ASSOCIATED EQUIPMENT <br /> MINIM .. -�\ RYKA CONSULTING <br /> Beal r <br /> ■IrILJ C11A I \ 5628 AIRPORT WAY <br /> U I EXISTING ROOFTOP SOUTH, SUITE 330 <br /> /�� = J ACCESS DOOR SEATTLE, WA 98108 <br /> EXISTING AT&T CABLE TRAY (TYP) .,_,- <br /> �r/ RFDS V2.00 DATED:02/21/2023 <br /> PROPOSED AT&T(3) FIBER& <br /> (3) POWER TRUNKS <br /> EXISTING AT&T (2) FIBER & <br /> (4) POWER TRUNKS 10 RE1WN 6299 <br /> `UPPER PORT GARDNER <br /> BUILDING <br /> ROOFTOP <br /> EXISTING BUILDING / <br /> PARAPET WALL (TYP) <br /> I- -' 1 <br /> 1321 COLBY AVENUE <br /> OUTLINE OF EXISTING AT&T <br /> EQUIPMENT ROOM WITHIN EVERETT,WA 98201 <br /> EXISTING PENTHOUSE (SEE \ SNOHOMISH COUNTY <br /> EQUIPMENT PLAN 1/A-3) ' 'N _. _ <br /> I T. REVISIONS <br /> EXISTING ROOFTOP <br /> EXISTING AT&T GPS I , DRAWN BY CHECKED APPROVED <br /> ANTENNA MOUNTED AT COAX z ACCESS LADDER RLD NJE RM <br /> DOG HOUSE (2 TOTAL) " \� 1 <br /> ` l REV. DATE DESCRIPTION BY <br /> \\ -5 A 12/22/22 ISSUED FOR 90%CD REVIEW RLD <br /> ./ EXISTING HVAC - - <br /> i EQUIPMENT (TYP) 0 02/13/23 ISSUED FOR 100%CONSTRUCTOR SL <br /> \, 1 03/0E/23 ISSUED FOR 100x CD REVIEW RLD <br /> I2 04/19/23 ISSUED FOR 100X CONSTRUCTION RLD <br /> )F-- <br /> EXISTING AT&T ROOFTOP �) ,h I I — ] - <br /> COAX DOGHOUSE TO REMAIN 1T,'•(' J _`\ <br /> ` EXISTING HVAC DUCTING C I <br /> EXISTING AT&T FC-12 BOX <br /> (TMP) • .$ <br /> (3 TOTAL)TO REMAIN 04-26-2023 <br /> EXISTING OTHER CARRIER I I RELOCATED AT&T ANTENNA A <br /> ROOFTOP COAX DOGHOUSE WITHIN EXISTING FRP CANISTER M C D <br /> © I W/ASSOCIATED EQUIPMENT `'" 'T// <br /> ,i+ n I �P'c OF WAS4, / i <br /> 1!_. ). <br /> 1��Aft \\ EXISTING OTHER CARRIER ` i <br /> \\\ 1 CABLE TRAY (TYP) _ 1 <br /> \\\\ 1 I ISTF32 W/ PROPOSED ' '111' . <br /> I <br /> L_ . ` \\ I )J I ANTENNA & EXISTING 0� 0.31 <br /> ! !IPTER5I , <br /> r \ril \CESS HATCH I 1 I d .______,�_. = <br /> 1 \� �� I �A <br /> °i d- !�E ET1A _. TITLE77 <br /> ��_ V? µV PROPOSED ROOFTOP PLAN <br /> • <br /> I I� <br /> L SHEET <br /> EXISTING NISTE AT&T VACANT FRP RELOCATED AT&T ANTE NA q_2 CANISTER TO REIdIW / WITHIN EXISTING FRP CANISTER �I -- <br /> 1 ASSOCIATED EQUIPMENT <br /> 4 ' PROPRIETARY INFORMATION: <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> TRCE.ORTH CONSTRUCTION DOCUMENTS IS PROPRIETARY BY <br /> NATURE. ANY USE OR DISCLOSURE OTHER <br /> 24"x36"SCALE: 1/4" = 1'-0" THAN THAT WHICH RELATES TO AT&T MOBIUTY <br /> 11"x17"SCALE: 1/8" = 1•-0" 4' 3• 2' 1' 0" 4' PROPOSED ROOFTOP PLAN 1 SERVICES IS STRICTLY PROHIBITED. <br />