/ Line: 2 Location:LIV
<br /> Quantity: 1 Trinsic V300,2110,DV,No Fin(Block Frame),Ext Bronze/Int White,U-Factor:.29,SHGC:.29,VT:.55
<br /> / PRIMARY ENTRY Ext Bronze/Int White General Notes
<br /> /
<br /> 1 No Fin(Block Frame)
<br /> * * 1
<br /> Argon Gas Filled
<br /> 4, / Model=Double Vent
<br /> Size=Net Frame:107 3/4"x 53 3/4"
<br /> Dimensions=Sash Width:One Quarter
<br /> ®milit' Aiiiiiii® Handing=XOX I—
<br /> Energy Package=Energy Star North-Central z
<br /> LIVING ROOM y Glass=DV 1.1 Left Vent,DV 1.1 Right Vent:3/32"SunCoat(Low-E)over 3/32"Clear with Gray
<br /> DINING 4. EdgeGardMAX Spacer,DV 1.1 Center Fixed:1/8"SunCoat(Low-E)over 1/8"Clear with Gray LJJ
<br /> EdgeGardMAX Spacer
<br /> Glazing=Dual Glaze with Argon
<br /> I E Hardware=SmartTouch Lock Li]
<br /> —mii, Other Options=Glazing Policy:This Window may ship open due to its size.Please contact your
<br /> Milgard Sales Representative for more information.
<br /> Screen=Standard with Fiberglass Mesh
<br /> Viewed From Exterior Ratings=STC:No Rating,OITC:No Rating,PG:R15
<br /> Clear Opening=W 24 5/8"x H 51 1/4"Sq.Ft.8.76,Egress:Yes n O
<br /> Other Ratings=CPD:MIL-A-294-02289-00001 I I
<br /> LLJ 1--
<br /> I r
<br /> Line: 3 Location:LIV I H
<br /> Quantity: 1 Trinsic V30O,2110,DV,No Fin(Block Frame),Ext Bronze/Int White,U-Factor:.29,SHGC:.29,VT:.55 H
<br /> Ext Bronze/Int White
<br /> No Fin(Block Frame) O
<br /> Argon Gas Filled Q u-
<br /> d Model=Double Vent M
<br /> n Size=Net Frame:95 3/4"x 53 3/4" 7
<br /> UNIT 10 2 T� Dimensions=Sash Width:One Quarter
<br /> N N
<br /> Handing=XOX s—
<br /> dI Energy Package=Energy Star North-CentralCO
<br /> Z Glass=DV 1.1 Left Vent,DV 1.1 Right Vent:3/32"SunCoat(Low-E)over 3/32"Clear with Gray
<br /> Qy ♦ EdgeGardMAX Spacer,DV 1.1 Center Fixed:1/8"SunCoat(Low-E)over 1/8"Clear with Gray
<br /> EdgeGardMAX Spacer
<br /> N
<br /> Glazing=Dual Glaze with Argon _IE
<br /> _ Hardware=SmartTouch Lock
<br /> it) Screen=Standard with Fiberglass Mesh
<br /> Ratings=STC:No Rating,OITC:No Rating,PG:R15
<br /> Cl)
<br /> iii
<br /> BEDROOM Viewed From Exterior Clear Opening=W 21 5/8"x H 51 1/4"Sq.Ft.7.7,Egress:Yes
<br /> Li
<br /> I Other Ratings=CPD:MIL-A-294-02289-00001 Q
<br /> I
<br /> w ^ Line: 4 Location:BED
<br /> BATHROOM
<br /> Quantity: 1 Trinsic V300,2110,HV,No Fin(Block Frame),Ext Bronze/Int White,U-Factor:.29,SHGC:.29,VT:.55
<br /> 0
<br /> Ext Bronze/Int White
<br /> a w No Fin(Block Frame)
<br /> ce
<br /> Argon Gas Filled
<br /> o /^+ Model=Half Vent
<br /> 0 {l'J1 \ / Size=Net Frame:71 3/4"x 53 3/4" No Rwbbn/Iww Dale
<br /> z Handing=XO
<br /> 3
<br /> I — Energy Package=Energy Star North-Central „e„mil,,.,,m
<br /> Glass=3/32"SunCoat(Low-E)over 3/32"Clear with Gray EdgeGardMAX Spacer
<br /> ^NORTH : SITE PLAN Glazing=Dual Glaze with Argon Northwest Permit Inc.
<br /> SCALE = 3/16"=1' + Hardware=SmartTouch Lock
<br /> w 0 Screen=Standard with Fiberglass Mesh
<br /> Ratings=STC:No Rating,OITC:No Rating,PG:R20 NORTHWEST PERMIT, INC.
<br /> Line: 1 Location:DINING 1026 SW 151st ST
<br /> Quantity: 1 Trinsic V300,2110,DV,No Fin(Block Frame),Ext Bronze/Int White,U-Factor:.29,SHGC:.29,VT:.55 Clear Opening=W 33 1/2"x H 51 1/4"Sq.Ft.11.92,Egress:Yes BURIEN, WA 98166
<br /> Ext Bronze/Int White E Other Ratings=CPD:MIL-A-294-02289-00001
<br /> No Fin(Block Frame) 1 / \ '1►+lbw
<br /> r
<br /> DESILVA WINDOW REPLACEMENT
<br /> Argon Gas Filled Viewed From Exterior L1612
<br /> 33RD ST
<br /> N
<br /> N Model=Double Vent 1102
<br /> 0 t i /
<br /> CV Size=Net Frame:71 3/4"x 53 3/4" EVEROT, WA
<br /> 98201
<br /> N Dimensions=Sash Width:One Quarter (HDI #11169045)
<br /> C. Handing=XOX
<br /> o Energy Package=Energy Star North-Central
<br /> Glass=DV 1.1 Left Vent,DV 1.1 Right Vent:3/32"SunCoat(Low-E)over 3/32"Clear with Gray
<br /> ♦ ♦ EdgeGardMAX Spacer,DV 1.1 Center Fixed:1/8"SunCoat(Low-E)over 1/8"Clear with Gray NWP #120764
<br /> EdgeGardMAX Spacer LIp ! EVERETT ore
<br /> Glazing=Dual Glaze with Argon IY OF10/17/2022 02
<br /> Hardware=SmartTouch Lock tr.' ' FOR PER.Rt- ED PERMIT
<br /> Screen=Standard with Fiberglass Mesh C�I L b 3/16' = 1'
<br /> \ / / ,, \ Ratings=STC:No Rating,OITC:No Rating,PG:R15
<br /> _ Clear Opening=W 15 5/8"x H 51 1/4"Sq.Ft.5.56 ........)
<br /> \\ Viewed From Exterior Other Ratings=CPD:MIL-A-294-02289-00001 c;Northwest Permit Inc. / NI Rights Reserved
<br />
|