7100 HARDESON RD 2023 Plans 2025-03-19
>
Address Records
>
HARDESON RD
>
7100
>
Plans
>
7100 HARDESON RD 2023 Plans 2025-03-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2025 7:50:08 AM
Creation date
3/19/2025 7:49:56 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Permit
FA2301-013
Year
2023
Notes
5 AEROSOL GENERATORS & RELEASING CONTROL PANEL IN DATA ROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2301-013 <br /> desDESON RD <br /> 171 Owner:Site SNOHOMISHHAR COUNTY PTBA <br /> Tenant:Ad r s : COMMUN7100ITYTRANSIT <br /> App.Date: 1/23/2023 <br /> 1 Proposed Use: FIRE ALARM <br /> Description: 5 AEROSOL GENERATORS&RELEASING <br /> err� CreekAdminCenter <br /> CONTROL PANEL IN DATA ROOM <br /> FIRE SUPRESSION SYSTEM - ?�'_ <br /> Reviewed By: <br /> INFORMATION Office Set Job Site Set Fire/Planning Set <br /> Q�1opo� <br /> _ Z�~ II IINNaN <br /> a Iiuy <br /> NAME TOWER SYMBOL BIT MANUFACTURER PART NO _ DESCRIPTOR E C7 <br /> 0 <br /> ADDRESS: 801 PINE STREET �0^'N <br /> SEATTLE,WA 98101 1 POTTER PFC4410RC RELEASING CONTROL PANEL 9 .; MI_ W 3 W 0 In W <br /> SCOPE OF WORK: 9 9 V 0 Z O Z 0 N z 3 <br /> 0 2 POTTER PS-24 CONVENTIONAL PHOTOELECTRIC SMOKE DETECTORy <br /> INSTALLATION OFA NEW AEROSOL FIRE SUPPRESSION AND DETECTION SYSTEM IN A DATA ROOM. .9 O pip w d F N N N <br /> THE SYSTEM CONSISTS OF 5 AEROSOL GENERATORS AND A RELEASING CONTROL PANEL I[] 2 POTTER EMS-IT-MARES AGENT RELEASE PULL STATION 0 <br /> FIRE ALARM CONTRACTOR FLAJ 2 POTTER 3001000 MrWIIALABORT SWTEC11 - I-- H J V V O W <br /> NAME PERFORMANCE SYSTEMS INTEGRATION I-1 1 POTTER PDC824 STEIL tNt t /�} OH LLU <br /> $� 9 D.v, NdILHJ <br /> ADDRESS: 301 PORTER WAY IHI 1 POTTER HS.24WR HORN STROBE,24 VDC,RED, <br /> MILTON.WA98354 •,_....'.,:, <br /> PHONE (425)3684201 61500E 5 STAT-X 15160 STAT-X 1500E GENERATOR <br /> FAX (425)3684208 0 <br /> QD 1 POTTER RCOS-I RELEASING CIRCUIT DIAABIF SWITCH e <br /> LICENSE NUMBER: WA.PERF05181250 0 \ <br /> 5 STAT-X 18015 STAT,%B'GENERATOR BRACKET ; / \\\l <br /> APPLICABLE <br /> ABLE CODER AND STANDARDS <br /> 5 POTTER 3005014 E-MATCH PROTECTION DEVICE - 4 1 <br /> NFPA 72 NATIONAL FIRE ALARM CODE 2016 EDITIONi. ADRIAN M.STEIK <br /> INTERNATIONAL BUILDING CODE 2018 EDITION 1 POTTER 3005012 END OF LINE RESISTOR AND DIODE ASSEMBLY 0 sm.s��.m..on�m INTERNATIONAL FIRE CODE 2018 EDITION <br /> NEPA 70 NATIONAL ELECTRICAL CODE 2017 EDITION 'WE eardmem w"ec OW. <br /> FIRE ALARM CABLE AND WIRE LEGEND _ '�''"°" �..3-0 <br /> CIRCUIT LABELING LEGEND LABEL WIRETYPE M PART NO. AWG RE`� <br /> FR DESCRIPTION <br /> A COWMAN 35777 16 4.09 2 COND.SOLID COPPER FPLR ANALOG UNSHIELDED N n <br /> SLC1 DEVICE IDENTIFIER <br /> SLC=SIGNALING LINE CIRCUIT <br /> B CDMTRAN 08700 14 3.07 T COND.SOLID COPPER FPLRFNAI.OGUNSHIELDED VICINITY MAP �, Z <br /> NAC=NOTIFICATION IRCUAPPLIANCE CIRCUIT <br /> 11 <br /> CIRCUIT IDENTIFIER C COWMAN 38898 16 4.39 16 AWG 2 COND.SOLID COPPER FPLR UNSHIELDED O <br /> D - --------- COMTRAN 38700 14 3.07 2COND.SOLID COPPER FPLR ANALOG UNSHIELDED <br /> ABBREVIATIONS <br /> A AMPERE J-BOX JUNCTION BOX <br /> AFF ABOVE FINISHED FLOOR kV KILOVOLT ., <br /> AHU AIR HANDLING kVA KILOVOLT AMPERE SHEET INDEX <br /> AL ALUMINIUMMINIUM kW KILOWATT <br /> AMP AMPERE kWh KILOWATT HOUR <br /> AWG AMERICAN WIRE GAUGE MFR MANUFACTURER <br /> BLDG BUILDING MECH MECHANICAL SHEET NO. SHEET DESCRIPTION I--_ <br /> C CONDUIT MIN MINIMUM <br /> CB CIRCUIT BREAKER (A) NEW I' <br /> CCTV CLOSED CIRCUIT TELEVISION NAC NOTIFICATION APPLOWCECIRCUIT STAT-X GENERATOR NOTES: FA0.1 TITLE SHEET ■ I Q IT) W <br /> CKT CIRCUIT NEC NATIONAL ELECTRIC CODE - <br /> CLG CEILING NEUT NEUTRAL FAD 2 FIRE SUPPRESSION DETAILS V O <br /> CO CONDUIT ONLY NFPA NATIONAL FlREPROTECTION ASSOCIATION •COMM COMMUNICATION NC NORMALLY CLOSED WALL MOUNTED GENERATORS SHOULD BE ANGLED AWAY FROM WALL 15 TO 30 DEGREES VERTICALLY,POINTED DOWN. ` , <br /> I---CU COPPER NIC NOT IN CONTRACT • THE AEROSOL GENERATORS MUST BE MOUNTED IN SUCH A WAY AS TO HAVE A CLEAR DISCHARGE PATH AND MUST NOT FA0.3 FIRE SUPPRESSION DETAILSW <br /> DCV DOUBLE CHECK VALVE NO NUMBER;NORMALLY OPEN DISCHARGE ONTO WALLS OR EQUIPMENT. — Z N <br /> DIA DIAMETER NTS NOT TO!'AI F FA1.1 DATA CENTER FLOOR PLAN-FIRE SUPPRESSION SYSTEM CO <br /> DISC DISCONNECT OD OVERHEAD DOOR;OVERALL DIAMETER • GENERATORS MUST BE MOUNTED IN A POSITION WHERE ITS"C-ZONE"(REQUIRED CLEARANCE ZONE)WILL NOT IMPACT ON _ <br /> ON DOWN PIV POST INDICATOR VALVE PERSONNEL,EQUIPMENT OR COMBUSTIBLE MATERIAL. FA2.1 BATTERY&CIRCUIT CALCULATIONS-FIRE SUPPRESSION SYSTEM r-, 0 11 I <br /> — <br /> DO DOOR OPERATOR PNL PANEL • GENERATORS SHOULD BE SPACED AS EVENLY AS POSSIBLE AROUND THE HAZARD AREA AND DIRECTIONALLY POSITIONED <br /> (E) EXISTING PVC POLYVIN&CHLORIDE(PLASTIC) TO PROMOTE A CIRCULAR,THREE DIMENSIONAL FLOW PATTERN. N I/04 <br /> EA EACH PWR POWER <br /> EF EXHAUST FAN CITY QUANTITY III <br /> ELEC ELECTRIC REOD REQUIRED STAT-XSUPRESSION DESIGN CRITERIA �I <br /> ELEV ELEVATOR RH RANGE HOOD <br /> EMT ELECTRICAL METALLIC TUBING RMC RIGID METAWC CONDUIT REQUIRED ROOM ROOM ROOM REQUIRED DESIGNED O <br /> EOL END OF LINE RESISTOR SF SUPPLY FAN;SQUARE FEET <br /> EOLR END OF LINE RESISTOR BLC SIGNALING LINE CIRCUIT k <br /> EXIST EXISTING SPEC SPECIFICATION CLEARANCE LENGTH WIDTH HEIGHT DENSITY DENSITY LLLL <br /> F FIRED ST SHUNT TRIP I <br /> FA FIRE ALARM STD STANDARD GENERATOR QUANITY ZONE (FEET) (FEET) (FEET) _ G/CU MI /(G CUM) ..1— <br /> W <br /> FAA FIRE ALARM ANNUNCIATOR TEL TELEPHONE GENERAL NOTES: <br /> FRCP FIRE ALARM CONTROL PANEL TELCOTELEPHONE COMPANY 1500E 5 78.7 INCHES 20 12 8 99 138 1--IJ 114 <br /> FAPS FIRE ALARM POWER SUPPLY TEMP TEMPORARY _.— <br /> FARA FIRE ALARM REMOTE ANNUNCIATOR TS TAMPER SWITCH 0 N <br /> FBI) FURNISHED BY OTHERS TYP TYPICAL • ALL FIRE ALARM SYSTEM WORK COMPLETED UNDER THE SCOPE OF THIS FIRE ALARM PLAN REVIEW SHALL BE FIELD <br /> mlFDC FIRE DEPARTMENT CONNECTION UGND UNDERGROUND VERIFIED BY FIRE INSPECTION PERSONNEL AND THE FIRE CODE OFFICIAL. <br /> FEC FIRE EXTINGUISHER CABINET UL UNDERWRITERS LABORATORIES • VISIBLE NOTIFICATION APPLIANCES SHALL REMAIN ACTIVE(FLASHING)WHEN THE AUTOMATIC AND MANUAL FIRE ALARM `� OW <br /> FH FIRE HYDRANT UON UNLESS OTHERWISE NOTED SYSTEM IS SILENCED. ---1 �FPL FIRE POWER LIMITED VOLT —J P V <br /> FPLR FIRE POWER LIMITED RISER VA VOLT AMPERE • FIRE ALARM SYSTEM SHALL TRANSMIT TROUBLE,SUPERVISORY AND FIRE SIGNALS DIRECTLY TO THE COMMUNICATIONS n III <br /> FPLP FIRE POWER LIMITED PLENUM VAC VOLTAGE,ALTERNATING CURRENT CENTER REMOTE SUPERVISING STATION. /� '^'�'S W <br /> FS WATER FLOW SWITCH VDC VOLTAGE DIRECT CURRENT F-5 ""`'1L9 T I� w <br /> FSD FIRE/SMOKE DAMPER VR VANDAL RESISTANT • MOUNT PULL STATIONS AT42'AT ACTIVATOR WITHIN5'OF LATCH SIDE OF EXIT DOORS `` >' 1- <br /> G GROUND W WATT • MOUNT AUDIO VISUAL DEVICES AT 80'ABOVE FLOOR LEVEL iC Ili E <br /> DEC GROUNDING ELECTRODE CONDUCTOR WI WITH • A DEDICATED 120VAC,20A BRANCH CIRCUIT BREAKER SHALL BE PROVIDED,MARKED IN RED,LOCK-ON PROVISION AND `—'� 1CCIJ E <br /> HEN GENERATOR WID WITTOIT MT HEAT TRACE WP WEATHERPROOF IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL'.THE LOCATION OF THE CIRCUIT BREAKER WILL BE PERMANENTLY IX INITIATING DEVICE CIRCUIT Z IMPEDANCE IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. <br /> F E B 1 3 2023 0 EUU S. CNG <br /> Adrian M.Steik <br /> CHECKED BY <br /> 000006E: 1/17/23 <br /> (Try OF FZTFETT <br /> ,P PROJECT NUMBEF, 23-003 <br /> • FA0 . 1 <br /> DRAWING ONLY TO SCALE IF PLOTTED AT 24'X 36' ODDER NUMBED. <br />