Laserfiche WebLink
SECTION VIEW <br /> LEGEND w <br /> 12 Scale 1"=4' z O � <br /> 16� W <br /> PER WASHINGTON ENERGY CODE SECTION 406, TABLE 0 ~ a3 <br /> 406.2 OPTION 1A: — 7 N <br /> • U-0.28 FENSTRATION IN MAIN FLOOR ADDITION. LLJ� >C04 <br /> D <br /> • R-10 RIGID INSULATION BELOW SLAB IN ADDITION. Q Q co <br /> EXISTING STRUCTURE Z Y¢w <br /> PROPOSED Z L'i 3 3 <br /> 6 12 S ---- ----- EXISTING CONCRETE � 0 = a7 CO <br /> to <br /> 2 ROUND WOOD - 2x4 ® 16" CTRS \\ Yz ROUND METAL <br /> GUTTER GUTTER <br /> e <br /> G~ <br /> ti - <br /> 8'-0" <br /> PVC ROLL ROOFING 30# ASPHALT SATURATED FELT <br /> L1J <br /> ROLL VENT ' n <br /> WATERPROOF BAFFLE/VENT METAL FLASHING V J <br /> RADIUS 17'-6" MIN 1" AIR SPACE O <br /> GUTTER TO MATCH EXISTING, <br /> DETAIL SHEET 18 -- _ Q <br /> FIERGLASS —- " N <br /> GUTTER 200 ® 16" CTRS a ti x L1- <br /> R-49 INSULATION ROOF FRAMING, FASTENERS, AND 1/2" WOOD LATHE <br /> BEAM PER DETAIL SHEET 18 AND PLASTER \ <br /> GYPSUM SHEETROCK <br /> R-21 FIBERGLASS INSULATION (36" CEILING,Y2" WALLS) <br /> z <br /> O <br /> N ® 112" 109 A" n <br /> V J <br /> 30# ASPHALT SATURATED FELT T <br /> WEATHERPROOFING DETAIL (SHEET 18) <br /> d USE APPROVED FRAMING ANCHOR AT W <br /> N )¢"x4" A & BETTER DOUBLE ALKYD EACH JOIST/BLOCK. USE (12) 16d <br /> PRIMED BEVEL CEDAR SIDING 5_ <br /> z NAILS AT EACH JOIST/BLOCK 3/4" 7&G WHITE OAK <br /> 3/4" PLYWOOD SUB FLOOR <br /> � HYDRONIC HEATING FASTENED DIAG. 1x8 SUBFLOOR <br /> CONT. RIM JOIST 2x10 ® 16"oc BELOW FLOOR SHEETING / n <br /> 2x10 ® 16" CTRS - - - _ 2'rl0' 16' CTRS - Z <br /> G G <br /> 3'-0" � � `� SO" SOLID BLOCKING AT O <br /> ill 3" MIN OVERLAP <br /> 1 �/G 24"oc IN OUTER 2 <br /> � JOIST BAYS <br /> GRADE GRADE HORIZONTAL FIRE REMOVE WALL/UNDERPIN GRADE U <br /> CONCRETE FOUNDATION PER PLAN VIEW AND WATERPROOF FOUNDATION W <br /> FOUNDATION DETAILS PER STRUCTURAL PLANS BLOCK (EACH BAY) STRUCTURAL DESIGN / n <br /> 7'-0" TO 7'-3" 2x4 ® 16"oc R-21 SPRAY FOAM SAME 7'-1" MIN v J <br /> INSULATION <br /> erg'-g" <br /> VERTICAL PT 2x4, SISTER 010'0c <br /> 6" HORIZ. (FIRE BLOCK V. GAP) HORIZONTAL FIRE 6" UN-R INFORETE <br /> BLOCK (EACH BAY) <br /> ONC <br /> WATERPROOF MEMBRANE 1" GAP HYDRONIC HEAT IN 3.5" CONCRETE FLOOR SLAB ON GRADE (INSULATED)' <br /> PRESSURE TREATED <br /> FREE DRAINING BACKFILL ( ) DETAIL SHEET 16 <br /> CONCRETE FLOOR ------------------- <br /> - - WASHED. DRAIN ROCK . .i:1 :1'.. `:• `. R �.. <br /> -- - f f f� i` `� `r' Z 'STEPPED FOOTING' PER PLAN ` <br /> SEWER LINE NON-WOVEN GEOTEXTILE, `:';�:'•: . -- PERFORATED <br /> ALONG NORTH WALL ONLY SOIL SEPERATOR �`}j y `" �Yf? 'SLAB ON GRADE (INSULATED)' AND DETAIL, SHEET 16 DRAIN PIPE <br /> R-10 RIGID DETAIL SHEET 16 <br /> PVC PERF PIPE INSULATION <br /> 15 of 19 <br /> EXISTING PROPOSED <br />