LEGEND
<br /> m JUNCTION BOX(AS NOTED)
<br /> kXo 15A, 120V, 1-PHASE DUPLEX RECEPTACLE
<br /> HUBBELL CATALOG#5262
<br /> 4 4-PLEX RECEPTACLE,(2)20A,DUPLEX
<br /> 5 ® 1 6 • 1-. RECEPTACLE. HUBBELL CATALOG#5362
<br /> OVERHEAD BUSWA0 �OVERHEAD BUSWA/ r OVERHEAD BUSWAY r OVERHEAD BUSWAY 15A, 120V, 1-PHASE DUPLEX RECEPTACLE DROP
<br /> / D HUBBELL CATALOG#5262
<br /> MATCHLINE EE DWG 40-31-1E65 / UD PLUG-IN BUSWAY W/TAP BOX, 208Y/120V,
<br /> x—x x x —I I—x—x x .-X x-X—x-1—z x—I I—x c 1 3-PHASE,4-WIRE,CEILING MOUNTED(HIGH BAY)
<br /> I
<br /> I I I I GENERAL NOTES
<br /> I NB 1. CONDUIT: 1/2"MINIMUM,3/4"MINIMUM FOR ALL
<br /> 2V31-2Bd15.5/7a,b,c — HOMERUNS.
<br /> DED 20
<br /> 3/4"C,4#12 & 1#12 GND x— %—x�.—x xQ15 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER,
<br /> ,, x .— INSULATION TYPE THHN/THWN, UNLESS OTHERWISE
<br /> 1 _: 0
<br /> I N7 NOTED.
<br /> x /H x—"µ x , U • I 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS
<br /> 7c 1 \ I WHICH DO NOT HAVE APPROPRIATELY COLORED
<br /> INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS
<br /> • I ARE ACCESSIBLE. IDENTIFY INSULATED GROUND
<br /> llll • S 1x CONDUCTORS IN ACCORDANCE WITH THE LASTEST NEC
<br /> tt21 tOb $1. (USING TAPE).COLOR CODE AS FOLLOWS:
<br /> 12e
<br /> 208Y/120V 480Y/277V
<br /> 1 ➢1 Tc j i A0(LEFT BUS IN PNL) BLACK BROWN
<br /> I`I B0(CENTER BUS IN PNL) RED ORANGE
<br /> I I —* . . T' '1 ,v/.. 4 5 CO(RIGHT BUS IN PNL) BLUE YELLOW
<br /> 1Db NEUTRAL WHITE GRAY
<br /> COLUMN MOUNTED FAN I I EQUIPMENT GROUND GREEN GREEN
<br /> — 7c — _ — 2V31-413f16.5/14,16,1e ISOLATED GROUND GRN/YEV GRN/YEL*
<br /> ui 11 'T'7c T O I (REF) •FN1 'GREEN WITH YELLOW TRACER
<br /> n _ = t ( x1�I' __ IC? BE 4. MO LABEL EACH RECEPTACLE,JUNCTION/OUTLET BOX
<br /> •5a •5b •5c 1 2V31-48E16 I eT fN7d I AND SWITCH WITH CIRCUIT IDENTIFICATION.
<br /> v 11208Y/120V,100A 15b 216
<br /> 3 I • I 113PH,4 WIRE PANEL . I. 29c R.T4 j4N C� /NY 2V31-2Bd15.5/5a,b,c 1 2V311E16/11,13 r ry ■ _ - - I� 1 .�.�i 1 6c 5 COMPLETION OF JOB.
<br /> PANEL SCHEDULES UPON
<br /> N .,:5 3/4"C,4112 & 1#12 GND 3/4"C I4�t10, 1I1OG N *If JnCI •�
<br /> I P F% -it,:''-- "°. f ,t 1b , _ 1 6. PANELS SHALL BE IDENTIFIED BY LAMINATED PHENOLIC
<br /> 30-13792 #1411 1 f; I^AB-- - -CI .!! - 10b J NAMEPLATES.
<br /> 6 •
<br /> —__J I I
<br /> = ILL J "-- ----i L 2V31-4Bf16.5/36c 7. ELECTRICAL CONTRACTOR SHALL VERIFY CHANGES WITH
<br /> 6 x�x 1 II- •"10 in si =,—-27y_ " 3/4"C-2#10, 1#16G CONSTRUCTION MANAGEMENT.WHEN CHANGES HAVE
<br /> METAL STRUT II E BEEN CONFIRMED,ACCURATELY"AS-BUILT THE
<br /> I��I1� Ailih
<br /> I 1 DRAWINGS TO INDICATE THE CHANGE NO EXCEPTIONS.
<br /> I 22b 24c I y.J 2V31114111,1 II ©' 11 n1 10b
<br /> 2V31-4Bf16/22b,24c 3/4"C-4 10, 1#tOG 2V31-4Ar16.5/10,12,15,21 •f1 X2V30-28Bd16/10,12
<br /> —, 3/4•C-4110, 1#1oc I I I „iv I\ 3/4"c- 4#10,1110G CONSTRUCTION NOTES
<br /> I) el, I I 1 c a KIDDE FIRE ALARM PANELS 71 > INSTALL 20A, DUPLEX RECEPTACLE ON FENCE AT
<br /> al /, al ( � s A A HEIGHT OF 48"ABOVE FINISHED FLOOR.
<br /> b 2V31r48116.5/ _
<br /> b' b M .� a"�I' I I ` i 21] INSTALL 1/2"CONDUIT WITH 4110, 1#10G FOR
<br /> Minn. 2V3 11-4 011 6/1 ..''�__ �
<br /> e - 1 c NEW CIRCUITS.
<br /> 4 4 I I . .
<br /> COLUMN MOUNTED FAN 131-48f16/1,3,5, �2V31-4E016/1,8,10 - 23 1� INSTALL 1/2"CONDUIT WITH 2#10, 1#TOG FOR
<br /> 1 1 ___ 61 1� te0 TR NCH I x 1 1/"C F8/14 PANEL 59-5-32 NEW CIRCUIT.
<br /> 10b +� YI OED 20
<br /> b 9b I I I I I� INSTALL 20A, DUPLEX RECEPTACLE WITHIN UTILITY
<br /> N 1i O 26a^A I — I x I — R — I VAULT PER BOEING STANDARDS.
<br /> �S I 30 KV4#1 "` BF © INSTALL 3/4"RGS CONDUIT WITH 4#10, 1#10G
<br /> "c 2V31-B116/9,26 COLUMN MOUNTED FAN MATCHLINE-SEE DWG 40-31-1E71 - WITHIN UTILITY TRENCH TO PANEL 2V31-4BE16.
<br /> 2V31-4Bf16.5 © INSTALL 20A DUPLEX RECEPTACLE ON UNISTRUT
<br /> 2V31-4Bf16 STAND AT A HEIGHT OF 48"ABOVE FINISHED
<br /> FLOOR.
<br /> PLAN VIEW O
<br /> m ® ®
<br /> 1E60 MI= B.
<br /> En1E70 En
<br /> 8' 4' 0 4' 8' 16' 0
<br /> KEY PLAN
<br /> GRAPHIC SCALE SCALE:NONE N
<br /> DRAWN 'GATE SUBDRE CURRENT REVISION SN801.
<br /> DATE
<br /> SW REVISION BY APPRA,m DALE SW REVISION BY /PRIMO DATE ACCEPTABILITY T.MESSANA PARTIAL 208Y/120V POWER PLAN U 02.03.20 g
<br /> R DUPLEX RECEPTACLE DROP INSTALLATION W2447423 80H TT/BAD 01.29.14 THIS DESIGN Nip//OR OHECKED
<br /> SPECIFIGTION IS APPROVED D.CLAYfON SHEET
<br /> S MXS GRINDER W2660918 AKC TT/840 6/24/14 ® kNOINUA
<br /> APPROVED BY DEPT. DATE D.BRAMPTON ' 1 E68T HAYWORTH CUBES W2652088 TN TT BAO 06.27.1tg)LAPZIEZArG CHECKED
<br /> U MAZAI MILLING MACHINE INSTALLATION W7066787 BDH TT/W 02.03.20 J.KOKO J.HAWN
<br /> BUILDING 40-031
<br /> J.KOKoctKA raB W7066787 DDNP4�D-031-tE68
<br /> T PROVED ELECTRICAL MASTER COL. BD-BF/15-17 EVERETL,WA DWG
<br /> 50. 40-031-1E68
<br />
|