My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1612 ROCKEFELLER AVE 2025-04-17
>
Address Records
>
ROCKEFELLER AVE
>
1612
>
1612 ROCKEFELLER AVE 2025-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 8:43:26 AM
Creation date
3/19/2025 2:54:46 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1612
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 of 9 <br /> Project Name: Foundation Stabilization/Lift - Everett Project Number: S220725-3XR <br /> Project Location: 1612 Rockefeller Ave, Everett, WA 98201 <br /> Client's Name: R&R Foundation Specialist, LLC <br /> Subject: 2-7/8" 0 Helical Pile - Compression Torque Chart - Digga MM-1OK <br /> Ideal Foundation Systems 2-7/9"0 Helical Pile 0.203-inch wall thickness -Soil Capacity er ESR-37SO <br /> DIGGA 10K Drive Head Torque,T Torque Correlation Factor,Itr Ultimate Axial Compressive Capacity, Allowable Axial Compressive <br /> Pressure(psi) (ft`Ibs) Compression(ft-=) P.=K,*T(kips) Capacity, P,=O.S'P„(kips) <br /> 500 1,740 9 15.7 7.8 <br /> 600 2,088 9 18.8 9.4 <br /> 700 2,436 9 21.9 11.0 <br /> 800 2,794 9 25.1 12.5 <br /> 900 3,132 9 28.2 14.1 <br /> 1000 3,480 9 31.3 15.7 <br /> 1100 3,828 9 34.5 17.2 <br /> 1200 4,176 9 37.6 18.8 <br /> 1300 4,524 9 40.7 20.4 <br /> 1400 4,872 9 43.8 21.9 <br /> 1500 5,220 9 47.0 23.5 <br /> 1600 5,568 9 50.1 25.1 <br /> 1700 5,916 9 53.2 26.6 <br /> 1800 6,264 9 56.4 28.2 <br /> 1900 6,612 9 59.5 29.8 <br /> 2000 6,960 9 62.6 31.3 <br /> 2100 7,308 9 65.8 32.9 <br /> 2200 7,656 9 68.9 34.5 <br /> MAX 1 2300 8,000 9 72.0 36.0 <br /> i.)DIGGA 1OK Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table 5A of ESR-3750,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,300 ft'Ibs.Per Ideal Manufacturing,Inc.,the <br /> maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,000 ft"Ibs.Final installation torque shall not exceed the lesser of these limiting values. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural package,but shall not <br /> exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and Ideal Manufacturing,Inc.documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in ft`lbs;the last torque reading taken during pile installation,using,for example,the torque reading instruments connected <br /> to the installation equipment. <br /> Kr=Torque correlation factor per ESR-3750 <br /> P"=Ultimate axial compressive capacity(in kips)of helical pile <br /> P.=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:P.=(T•K,)/2 <br /> vii.)1 kip=1,000 Ibs <br />
The URL can be used to link to this page
Your browser does not support the video tag.