Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: P2306-004 Description: INSTALL NEW FIXTURES FOR RESIDENTIAL REMODEL <br /> Applied:6/5/2023 Approved: 6/5/2023 Site Address: 2311 HARRISON AVE <br /> Issued:6/7/2023 Finaled: 1/2/2024 City,State Zip Code: EVERETT,WA 98201 <br /> Status: FINALED Applicant:THOMAS WILKINSON <br /> Parent Permit: B2210-067 Owner:WILKINSON THOMAS H <br /> Parent Project: Contractor: OWNER <br /> Details: <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 6/16/2023 6/16/2023 PLUMB 07-OTHER JASON NO ACCESS COVER <br /> MORRISSEY <br /> Notes: <br /> 206-793-6220 <br /> TOMW@EXPERTDRYWALL.COM <br /> -No one onsite. It appears as though someone is living in home.Unable to complete inspection. Need owner or contractor/plumber onsite for <br /> inspection. <br /> 6/22/2023 6/22/2023 PLUMB 03-ROUGH JASON CORRECTION see notes <br /> IN MORRISSEY REQUIRED <br /> Notes: <br /> 206-793-6220 <br /> TOMW@EXPERTDRYWALL.COM <br /> Submit Delete Note <br /> jjm changed Inspection Type from PLUMB 07-OTHER to PLUMB 03-ROUGH IN <br /> *** Multiple Code corrections on DWV and Water Distribution System.-Missing nail plates on water piping and waste and vent piping.Per the UPC <br /> 312.9 Steel Nail plates 18 gauge with 11/2"overlap.-Non code wet venting on existing downstairs bath and new bath per the UPC chap 9.-Non code <br /> use of fittings see UPC chap 707.1-706.4-No test on DWV system per the UPC 712.1 Water Test.-Insufficient pipe support in multiple locations for pex <br /> and ABS pipe.every 32"horizontal for pex and at each floor and mid story vertically.ABS is every 4'horizontal and each floor and mid story vertically.- <br /> Trap for washer cannot be below floor and there is no vent.-Also appears to be no venting for existing bath fixtures.-Leak on existing bath tub trap.*** <br /> RECOMMEND HAVING LICENSED PLUMBING CONTRACTOR MAKE REPAIRS IN ORDER TO PASS INSPECTION AND ENSURE SYSTEM IS SAFEH ***THIS <br /> CORRECTION LIST IS NOT EXHAUSTIVEM <br /> 7/5/2023 7/5/2023 PLUMB 03-ROUGH JASON CORRECTION see notes <br /> IN MORRISSEY REQUIRED <br /> Notes: <br /> 7/3/2023 3:29 PM Thomas Wilkinson <br /> Contact Name:Thomas Wilkinson <br /> Site Address:2311 HARRISON AVE <br /> Phone:2067935348 <br /> e-Mail:TOmmyhO369@gmail.com <br /> -Run 2"vent through roof for existing front main floor bath.No mechanical vent for toilet.Per the UPC chap 9.Also need to meet cross sectional area.- <br /> Roll 3"combo for clean-out on its side or above floor and or to exterior per the UPC 707.9 Clearance-Attach water lines in crawlspace to bottom of floor <br /> or other location supporting every 32".-Protect water lines running through foundation.*** Downstairs east bath,non code horizontal wet vent <br /> system.Cap San tee and tie in lav on horizontal.-310.3 Waste Connection No waste connection shall be made to a closet bend or stub of a water closet <br /> I <br /> Printed:Thursday,04 January, 2024 1 of 3 rk <br /> SUPERION <br />