My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10111 9TH AVE W EMERALD COURT APARTMENTS 2025-04-18
>
Address Records
>
9TH AVE W
>
10111
>
EMERALD COURT APARTMENTS
>
10111 9TH AVE W EMERALD COURT APARTMENTS 2025-04-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2025 2:45:44 PM
Creation date
3/20/2025 10:56:22 AM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE W
Street Number
10111
Tenant Name
EMERALD COURT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SittS&hill Tac253 o-474ma,Washington Designed: OMA Date: 11/1/2022 Project Number: 19.933 <br /> -9449 Checked: CJT Date: 11/4/2022 7 <br /> Project: Emerald Court Carports <br /> LATERAL ANALYSIS.CONTINUED <br /> WIND DESIGN CRITERIA: <br /> Velocity pressure shall be determined as permitted by 2018 IBC Section 1609.1 in <br /> ASCE 7-16 Chapter 26. <br /> V:=98 mph basic wind speed,Section 26.5 <br /> B exposure category,Section 26.7.3 <br /> KZ:=0.57 MWFRS velocity pressure expose coefficient,Table 26.10-1 <br /> Kzt:=1.0 topographic factor,Section 26.8.2 <br /> Kd:=0.85 wind directionality factor,Table 26.6-1 <br /> Ke=0.98 ground elevation factor,Table 26.9-1 <br /> qZ:=0.00256•K •KZt•Kd•Ke•VZ •( psi /=11.671 psi velocity pressure, (26.10-1) <br /> `mph2 <br /> 9h =qz as permitted by Section 26.10.2 <br /> CHECK SNOW LOADING PER ASCE CHAPTER 7 <br /> Velocity pressure shall be determined as permitted by 2018 IBC Section 1609.1 in <br /> ASCE 7-16 Chapter 26. <br /> pg:=15 psi Per Table 7.2-5 <br /> Ce:=1.0 Exposure Factor per Table 7.3-1 <br /> Ct:=1.2 Thermal Factor per Table 7.3-2 <br /> ! :=1.0 Importance Factor <br /> pf:=.7•pg•Ce•Ct•/5=12.6 psi Flat Roof Snow Load <br /> max(25 psi,pf)=25 psi Min.City required Uniform Flat Roof Snow Load <br /> NOTE: <br /> Snow load design will be based on the following: <br /> Uniform Snow Load check per the City required minimum uniform load of 25psf. <br /> Unbalanced Snow Load: Per Section 7.6.1 unbalanced snow loads are not required for roofs <br /> with slopes of 1/2 on 12 or less. <br /> Partial Loading per Section 7.5 will be checked based on the ASCE required flat roof snow load <br /> determined above. <br />
The URL can be used to link to this page
Your browser does not support the video tag.