My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4330 COLBY AVE 2025-04-14
>
Address Records
>
COLBY AVE
>
4330
>
4330 COLBY AVE 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 11:36:57 AM
Creation date
3/20/2025 11:08:32 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4330
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 of 21 <br /> PROJECT NO. SHEET NO. <br /> S220906-1 XR <br /> PROJECT 4332 Colby Ave, Everett, WA 98203 <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY NJ DATE 11/13/22 <br /> Ideal Foundation Systems 2-7/8"0 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR 3750 <br /> DIGGA 6K Drive Head Torque Correlation Factor,Kt Ultimate Axial Compressive Allowable Axial Compressive <br /> Torque,T <br /> Pressure (ftlbs) Compression Capacity,P.=Kr*T Capacity, P.=0.5 P„ <br /> (psi) (ft-') (kips) (kips) <br /> 500 1,554 9 14.0 7.0 <br /> 600 1,865 9 16.8 8.4 <br /> 700 2,176 9 19.6 9.8 <br /> 800 2,486 9 22.4 11.2 <br /> 900 2,797 9 25.2 12.6 <br /> 1000 3,108 9 28.0 14.0 <br /> 1100 3,419 9 30.8 15.4 <br /> 1200 3,730 9 33.6 162 <br /> 1300 4,040 9 36.4 18.2 <br /> 1400 4,351 9 39.2 19.6 <br /> 1500 4,662 9 42.0 21.0 <br /> 1600 4,973 9 44.8 22.4 <br /> 1700 5,284 9 47.6 23.8 <br /> 1800 5,594 9 50.3 25.2 <br /> 1900 5,905 9 53.1 26.6 <br /> 2000 6,216 9 55.9 282 <br /> MAX 2100 6,527 9 58.7 29.4 <br /> i.)DIGGA 6K Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table SA of ESR-3750,the maximum installation torque rating of a 2-7/8"¢ helical pile(0.203-inch wall thickness)is 8,300 ft*Ibs.Per Ideal <br /> Manufacturing,Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,000 ft*tbs.Final installation torque shall not <br /> exceed the lesser of these limiting values. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural <br /> package,but shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and Ideal Manufacturing,Inc documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in ft*lbs;the last torque reading taken during pile installation,using,for example,the torque reading <br /> instruments connected to the installation equipment. <br /> Kt=Torque correlation factor per ESR-3750 <br /> Pa=Ultimate axial compressive capacity(in kips)of helical pile <br /> Pa=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:Pa=(T*KJ/2 <br /> vii.)1 kip=1,000Ibs <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.