My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
613 40TH PL 2025-04-22
>
Address Records
>
40TH PL
>
613
>
613 40TH PL 2025-04-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2025 2:31:59 PM
Creation date
3/20/2025 11:38:19 AM
Metadata
Fields
Template:
Address Document
Street Name
40TH PL
Street Number
613
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> BLDG 09-FIRE <br /> 12/12/2023 12/12/2023 STOPPING/BLOCKIN RAKEEB KHAN APPROVAL as noted <br /> G <br /> Notes: <br /> Contractor finishing fire stopping as discussed. <br /> 12/20/2023 12/20/2023 BLDG 12- RAKEEB KHAN APPROVAL <br /> INSULATION <br /> Notes: <br /> 971-371-9443 <br /> Owner is adding insulation in exterior wall of new bathroom downstairs. <br /> 1/3/2024 1/3/2024 BLDG 10-DRYWALL RAKEEB KHAN APPROVAL <br /> NAILING <br /> Notes: <br /> wikadesigns22@gmail.com <br /> rfk changed Inspection Type from BLDG 08-FRAMING to BLDG 10-DRYWALL NAILING <br /> 3/20/2024 3/20/2024 BLDG 15-OTHER RAKEEB KHAN TOTHER <br /> Notes: <br /> Inspection of ramp.Ramp slope ok.Need min 3 foot landing at bottom of ramp. <br /> 3/28/2024 3/28/2024 BLDG 16-FINAL BLDG INSPECTOR CANCELLED CUSTOMER CALLED AND CANCELED <br /> Notes: <br /> wikadesigns22@gmail.com <br /> CUSTOMER CANCELLED <br /> 4/8/2024 4/8/2024 BLDG 16-FINAL RAKEEB KHAN CORRECTION *AM PREF* <br /> REQUIRED <br /> Notes: <br /> wikadesigns22@gmail.com <br /> Not ready.Need all sub permit final approval.One bathroom on main floor is planned to be a staff only bathroom.Old master bath requires toilet grab <br /> bar to be updated to max 30"apart and either a swing up bar or 36"long horizontal bar.Smoke detector/carbon monoxide detectors need to be <br /> interconnected on all floors.Missing carbon monoxide detector in hallway.Smoke detector in lower floor too close to kitchen.Ramp handrails need <br /> additional support and need ends to return to post. <br /> 4/11/2024 4/11/2024 BLDG 16-FINAL RAKEEB KHAN CANCELLED CUSTOMER CALLED AND CANCELED <br /> Notes: <br /> 971-371-9443 <br /> CUSTOMER CALLED AND CANCELLED <br /> 4/22/2024 4/22/2024 BLDG 16-FINAL RAKEEB KHAN CORRECTION <br /> REQUIRED <br /> Notes: <br /> Benard Musungu 971-371-9443 <br /> Fixed grab bar in water closet is required to be min 36"and 12"from the rear wall per irc r330.8.3.1. <br /> 4/25/2024 4/25/2024 BLDG 16-FINAL RAKEEB KHAN APPRVD-PERMIT <br /> FINAL <br /> Notes: <br /> Benard Musungu 971-371-9443 <br /> I <br /> Printed:Thursday,20 March, 2025 2 of 3 <br /> SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.