ghUK I tYVtb MEMBER REPORT PASSED <br /> Roof Deck, DB-4 <br /> 3 piece(s) 1 3/4"x 9 1/2" 1.55E TimberStrand® LSL <br /> C.vrall_=ncr:h:12'E <br /> 0 0 <br /> i r <br /> Q El <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 2752 @ 1 1/2" 7088(1.50") Passed(39%) -- 1.0 D+0.75 L+0.75 5(All Spans) Member Type:Drop Beam <br /> Shear(Ibs) 2396 @ 11" 11854 Passed(20%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Use:Residential <br /> Building Code:IBC 2015 <br /> Moment(Ft-Ibs) 8428 @ 6'3" 17977 Passed(47%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.226 @ 6'3" 0.408 Passed(L/650) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load Defl.(in) 0.417 @ 6'3" 0.613 Passed(L/353) -- 1.0 D+0.75 L+0.75 5(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Snow Factored Accessories <br /> 1-Hanger on 9 1/2"DF beam 1.50" Hanger' 1.50" 1283 625 1406 2806 See note 1 <br /> 2-Hanger on 9 1/2"DF beam 1.50" Hanger' 1.50" 1283 625 1406 2806 See note' <br /> •At hanger supports,the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br /> •'See Connector grid below for additional information and/or requirements. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 12'3"o/c <br /> Bottom Edge(Lu) 12'3"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Connector: Simpson Strong-Tie <br /> Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br /> 1-Face Mount Hanger HU612 2.50" N/A 22-16d 8-16d <br /> 2-Face Mount Hanger HU612 2.50" N/A 22-16d 8-16d <br /> •Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 1 1/2"to 12'4 1/2" N/A 15.6 -- -- <br /> 1-Uniform(PSF) 0 to 12'6"(Top) 1' 15.0 60.0 25.0 Deck <br /> 2-Uniform(PSF) 0 to 12'6"(Top) 1' 15.0 40.0 - House <br /> 3-Uniform(PLF) 0 to 12'6"(Top) N/A 100.0 - - Wall Above <br /> 4-Uniform(PLF) 0 to 12'6"(Top) 1 N/A 60.0 - 200.0 Roof <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 1/25/2023 11:11:05 PM UTC <br /> Andreas Quinn <br /> Bykonen Carter Quinn A ForteWEB v3.5, Engine:V8.2.3.63,Data:V8.1.3.6 <br /> avq@bcq-se.com(206) 84 File Name: Greenleaf Garage Iti1A <br /> Weyerhaeuser �'1 <br /> Pang,R /q <br />