My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10524 13TH AVE W A&B 2025-04-07
>
Address Records
>
13TH AVE W
>
10524
>
10524 13TH AVE W A&B 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2025 8:37:52 AM
Creation date
3/21/2025 8:00:02 AM
Metadata
Fields
Template:
Address Document
Street Name
13TH AVE W
Street Number
10524
Unit
A&B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit #: B2404-042, Second Building Review <br /> August 5, 2024 <br /> Architectural (Reviewer: Anita Chen) <br /> 1. Please coordinate the proposed Energy Code upgrades with the details. Please show the exterior <br /> insulation as proposed on sheet A2. Please update all details accordingly. <br /> 2. No further action required. <br /> 3. On sheet 12, detail A3, please show add notes clarifying wood decay resistance and hardware <br /> corrosion resistance. See R317.1 and R317.3. <br /> Please add IRC R317.3 to General Notes. <br /> 4. No further action required. <br /> 5. No further action required. <br /> 6. No further action required. <br /> 7. No further action required. <br /> 8. No further action required. <br /> 9. (IRC 302.1)The proposed duplex has overhangs within the 5ft setback from the property line. Please <br /> provide a 1-hour fire-resistance rating on the underside of the overhang OR fireblocking per Note <br /> (a) OR no ventilation per Note (b). <br /> 10. (IRC R311.3) Please provide a landing an all exterior doors. The door at the kitchen/living room <br /> requires an exterior landing: <br /> R311.3 Floors and Landings at Exterior Doors <br /> There shall be a landing or floor on each side of each exterior door. The width of each <br /> landing shall be not less than the door served. Landings shall have a dimension of not less <br /> than 36 inches (914 mm) measured in the direction of travel. The slope at exterior landings <br /> shall not exceed 1/4 unit vertical in 12 units horizontal (2 percent). <br /> 11. Please provide anchorage for water heater per IRC M1307.2. <br /> Structural (Reviewer: Ben Monk) <br /> 1. No further action required. <br /> 2. No further action required. <br /> This review has been performed for general compliance with the building codes as adopted and amended by <br /> the state of Washington and the city of Everett. Corrections and comments made during the review process <br /> do not relieve the project from compliance with code and permit requirements. The designers-of-record are <br /> responsible for a complete design in accordance with the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Anita Chen <br /> Building Plan Review Technician <br /> (425) 257-7805 <br /> AChen@everettwa.gov <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 2 <br />
The URL can be used to link to this page