im EVERETT PUBLIC WORKS REVIEW WORKSHEET <br /> WASHINGTON <br /> PROJECT ADDRESS: 2310 VIRGINIA AVE Permit#:B2302-115 <br /> DESCRIPTION OF WORK: DADU-NEW CONSTRUCTION 880 SQFT DADU LOCATED NEAR REAR OF LOT <br /> PW Reviewer to select all that apply below: <br /> Utility Permits (Note:Permit Technicians to Create Utility Permit for Sewer, Water,Fire,and Irrigation,as selected below) <br /> SANITARY SEWER: DOMESTIC WATER SERVICE:(Attach Calculation&Cost Est.) <br /> El New Connection to main plus connections to building ❑ New Connection,Size - ❑Per Cost Estimate <br /> ® Alteration ❑ Meter Only,Size -❑Per Cost Estimate <br /> O Repair ❑ Water System Development Fee Total:$ <br /> ❑ Cap-off,quantity ❑ Sewer System Development Fee Total:$ r may <br /> ❑ Reconnection to stub ® Water Service Line(behind meter),Size 3/4-INCH <br /> El Backwater Valve 0 Backflow Prevention(Outside Building):❑RPBA ❑DCVA <br /> ❑ NOT REQUIRED ❑ NOT REQUIRED <br /> Explanation/Utility Permit# Explanation/Utility Permit# <br /> IRRIGATION SERVICE:(Not Including Cost Estimates) FIRE SERVICE:(Attach Cost Estimate/Request for Reference) <br /> ❑ New Connection,Size ❑ New Connection,Size -['Per Cost Estimate <br /> ❑ Meter Only,Size ❑ %"Detect Meter Only,Service Size <br /> ❑ Water System Development Fee Total:$ ❑ Backflow Prevention(Outside Building):❑DCDA <br /> ❑ Backflow Prevention(Outside Building):❑ DCVA ® NOT REQUIRED <br /> ® NOT REQUIRED Explanation/Utility Permit# <br /> Explanation/Utility Permit# <br /> WATER DEPARTMENT COST ESTIMATE NEEDED-(lf yes,PW Reviewer to send cost estimate request to Water Department) <br /> ❑ Yes,Quantity ,See attached for reference. <br /> ® NOT REQUIRED <br /> Plumbing Permits(Note:Permit Technicians to add all items selected below to Plumbing Permit for items inside building only) <br /> Backflow Prevention(Inside Building): ❑DCVA(for Domestic service) ❑RPBA(for Domestic service) ❑DCDA(for Fire service) <br /> ® NOT REQUIRED <br /> Building Permits(Note:Permit Technicians to add all items selected below to associated Building Permit) <br /> STORMWATER SYSTEM DEVELOPMENT FEES: TRAFFIC MITIGATION FEES: <br /> ® YES,❑See Attached for calculations/credit ❑ YES,Traffic Mitigation Total:$ <br /> To be added on PWPW2309-009 To be added on B2302-115 ❑See Attached for calculations/credit <br /> Quantity charged 732SF Quantity charged 440SF ® NOT REQUIRED <br /> QTY is®Ground only❑all surfaces QTY is®Roof only❑all surfaces <br /> $196.03 $117.83 D <br /> ❑ NOT REQUIRED <br /> Additional Checklists: <br /> ADDRESS LETTER REQUIRED? (If yes(new assigned address),print out Address Letter from TRAKiT Print Menu and include) <br /> ® YES—TYPE:❑SFR ❑DUPLEX ®ADU ❑INFILL DWELLING ❑MULTI-FAMILY ❑COMMERCIAL <br /> ®See Attached Letter,2 copies(Permit Techs to issue one copy to applicant with permits,scan one copy to Jeffrey Marks) <br /> ®Digital copy attached to permit record,Permit#B2302-115 <br /> ®Saved to Address Folder in Development Tech File <br /> ❑ NOT REQUIRED <br /> FIRE SPRINKLERS REQUIRED? <br /> ❑ YES—Type <br /> ® NOT REQUIRED <br /> Reason: <br /> PUBLIC WORKS PERMIT REQUIRED? <br /> ® YES,Permit#PW2309-009 <br /> ®Stormwater NPDES Tab Completed in TRAKiT ®ADA Tab Completed in TRAKiT ® Inspections Added in TRAKiT <br /> ❑ NOT REQUIRED <br /> Worksheet Completed By:,74Clei V.1.443/te Date:0910S/2023 <br /> Worksheet Reviewed By: . Date: o".0 8- 2023 <br /> r <br />