My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2310 VIRGINIA AVE B 2025-08-19
>
Address Records
>
VIRGINIA AVE
>
2310
>
2310 VIRGINIA AVE B 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 2:29:06 PM
Creation date
3/21/2025 8:04:24 AM
Metadata
Fields
Template:
Address Document
Street Name
VIRGINIA AVE
Street Number
2310
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
from the rear property line, 10-feet from the north side property line, and 8'from the south side property <br /> line. The ADU will exceed the required setbacks. <br /> Roof Lines: The Guidelines require all new buildings to feature prominent pitched roofs which slope a <br /> minimum 6:12 vertical to horizontal ratio and maximum 12:12 ratio. The proposed ADU will have a 6:12 <br /> roof pitch. <br /> Windows and Doors: The Guidelines state that windows with frames made of vinyl, fiberglass or similar <br /> materials may be used on new construction, but they should be recessed, and wood window trim <br /> constructed around the frame to provide window depth consistent with the character of the historic <br /> neighborhood. Front doors should be consistent with the architectural style of the house and neighboring <br /> homes. Window proportions should match the architectural style of the house and openings should <br /> indicate floor levels and should not occur between floors except where historically accurate. The ADU <br /> will consist of vertically proportioned windows consistent with the character of the historic neighborhood. <br /> Two fiberglass doors are proposed: the entry door on the east elevation and the door leading to the <br /> second-story deck on the north elevation. The plans indicate that will windows and doors will be wrapped <br /> in 1 by 4 white wood. <br /> Exterior Materials: The guidelines require traditional materials consistent with the scale and character of <br /> the street. The proposed exterior building materials include cedar bevel siding to match the main <br /> residence, composite shingle roofing, 1 by 10 white wood, and cedar pickets and railing for the deck. <br /> These materials are generally consistent with the neighborhood character. <br /> Alleyways, Vehicular Access, and Parking:The Guidelines state that on all sites served by alleys, access to <br /> off-street parking shall be via the alley and no driveways from the main street will be permitted. A <br /> driveway is proposed off of the alley and three off-street parking spaces will be provided via the alley. The <br /> driveway and parking spaces shall meet the Public Works design and construction standards and will be <br /> reviewed with the Public Works permit. A driveway is not proposed off of Virginia Ave. <br /> Infill in Rear Yards: The Guidelines state that the design of the new building should be in character with <br /> the existing building and the neighborhood and secondary in size and scale. The existing house should be <br /> retained with minimal addition and the infill building should not have significant adverse effects upon <br /> neighboring properties. There should be enough separation between the existing building and infill <br /> building to provide useable open space. To retain openness to the alley, infill in the rear yards should be <br /> limited in width so as not to create a wall on the edges of the alley. Infill buildings should be visible from <br /> the sidewalk to enable identification and pedestrian access should be provided and identifiable from the <br /> sidewalk. <br /> The proposed ADU will be approximately 23-feet tall. Per EMC 19.22.020,Table 22-2,the maximum height <br /> allowed is 24-feet. Since the proposed height is within 1-foot of the height limit, a height survey will be <br /> required. As noted above, the exterior materials of the ADU will visually match the existing house. No <br /> changes are proposed to the existing house and adverse effects upon neighboring properties are not <br /> anticipated. A 20-foot separation is proposed between the existing house and ADU, providing plenty of <br /> usable open space for the residents. The lot is 50-feet wide and the ADU will be 22-feet wide (plus the <br /> 10-foot deck); therefore, the openness of the alley will be retained. The ADU's visibility from the street <br /> will be limited due to the placement of the existing house, vegetation, and fencing on the south side. <br /> However, pedestrian access will be identifiable from the sidewalk and provided via a walkway on the north <br /> side of the existing house. <br /> Page 3 of 4 <br /> REV123-020 <br /> EVERETT <br />
The URL can be used to link to this page
Your browser does not support the video tag.