4 GENERAL NOTES
<br /> -IV
<br /> 1. CONTRACTOR SHALLOWNER.
<br /> COMPLY WITH THE CURRENT'GENERAL CONDITIONS,"AND BUILDING STANDARDS AS PROVIDED I J r
<br /> - BY THE BUILDING OWNER. - � -
<br /> 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. r _
<br /> _ I
<br /> 3. DO NOT SCALE DRAWINGS.CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. --{ I i - r ( I P O I N T OF VISION
<br /> E _ - 1L -rr•1 - �.j -j I ' _ _ - ex cx.recruaec services4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL JWWEXISTING
<br /> - - _..rrr_ 3 -
<br /> PRIORTOFABRICATIONORCONSTRUCTION.CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS _ - - - -
<br /> REQUIREMENT. _ 1628 46th Street BE, Everett,WA 98203
<br /> EXISTING FENCE point_of_vi Sion 2 fro ntier.com
<br /> 5. ALL MODIFICATIONS,REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN NEW FENCE (4 2 5)7 7 2-8 2 0 7
<br /> WRITING BY OWNER AND/OR ARCHITECT. _ I _ NEW T W.GATE
<br /> 6. WITHIN FIVE(5)BUSINESS DAYS OF START OF CONSTRUCTION,THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ` NEW EXTENDED
<br /> ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT CONIC.WALK EXISTING CONC.WALK -
<br /> REQU RED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH
<br /> SHORTER LEAD TIMES,PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION,OF EXISTING FENCEi `
<br /> DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT.
<br /> 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST r
<br /> LOCAL BUILDING CODES AND ORDINANCES.
<br /> B. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR
<br /> QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK.DO NOT SCALE THE DRAWINGS.
<br /> 9. THE USE OF WORD"PROVIDE"SHALL ALWAYS MEAN,"FURNISH AND INSTALL,CONNECT,OR SECURE"AS REQUIRED.
<br /> 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN
<br /> INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. r
<br /> 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE.THIS SCHEDULE SHALL INCLUDE DELIVERY
<br /> LEAD TIMES OF CONSTRUCTION ITEMS,AND START AND COMPLETION DATES OF EACH PHASE.THE CONTRACTOR `
<br /> SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS.
<br /> i
<br /> - 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. � � •
<br /> 13. ACCESS TO AND FROM THE PROJECT SITE,SPECIAL CONDITIONS,NOISY WORK,TIMING OF WORK,INTERRUPTION OF
<br /> MECHANICAL AND ELECTRICAL SERVICES,RELOCATION OF EXISTING EQUIPMENT,CASEWORK,FIXTURES,FITTINGS,
<br /> ETC.,MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. .'7
<br /> 14. ADEQUATE CLEANUP,PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE
<br /> ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT Tenant Improvements:
<br /> THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. ._ Y
<br /> 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT
<br /> THEIR OWN EXPENSE.THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS:COMMON HALLWAYS,FREIGHT
<br /> ELEVATOR VESTIBULES,ETC. I{� E%IBTING PLANTER I-rNEW 3'W.GATE '
<br /> 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. v r� DEMOLISHED PLANTER ANEW 14'W.GATE -
<br /> -a 17. UPON COMPLETION OF ALL CONSTRUCTION,THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF /ACCESS LASER
<br /> "RECORD"AS-BUILT DRAWINGS. NEW 14'W.ROLLING - --
<br /> I GATE FENCE
<br /> 18. ALL MATERIALS TO BE NEWUON. O -DEMOLISHED Access Laser
<br /> I }
<br /> 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEWWORK AND AS REQUIRED FOR -------EXISTING CMU 2211 W Casino Rd Unit Al
<br /> FINISHED APPEARANCE. ENCLOSURE Everett, WA 98204
<br /> 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING,BLOCKING,AND FRAMING FOR `� _NEW FENCE
<br /> LIGHT FIXTURES,ELECTRICAL FIXTURES,CASEWORK AND ALL OTHER ITEMS REQUIRING IT.
<br /> 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. �v _ I
<br /> 22, ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECTS CONTROL SAMPLES AND REQUIRE ARCHITECTS EXISTING FENCE
<br /> REVIEW PRIOR TO INSTALLATION.SUBMIT TO ARCHITECT THREE(3)COPIES FOR REVIEW.
<br /> t -
<br /> 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK,MILLWORK AND ANY OTHER SPECIAL -
<br /> ITEMSREQUIRINGCUSTOMSHOPFABRICATION.SUBMIT TO ARCHITECT AT LEAST THREE(3)COPIES FOR REVIEW.
<br /> 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IFDRAWN IN �+
<br /> THROUGHOULL. SITE PLAN
<br /> 25. THROUGHOUT IS NOT
<br /> I DRAWINGS ARE ABBREVIATIONS.THEHICH ARE IN ARCHITECT
<br /> COMMON USE.E THE I T OF ENT OF ANY
<br /> IN
<br /> PROVIDED IS NOT INTENDED TO BEACOMPLETE LIST.THEARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. 30'-0° ARCHITECTS RESPONSIBILITY TERMINATES UPON ISSUANCE OF
<br /> 26. ALL SURFACES WHERE WORK IS DONE TO BE PATCHED AND FINSHED TO MATCH ADJACENT SURFACES. BUILDING PERMIT RAFTINGCOMMENCEMENTEDRA CONSTRUCTION AND
<br /> IS LIMITEDTODRAFTINGANDIORREDRAFTINGOF WORKING
<br /> _p DRAWINGS IN REGARDS TO ERRORS ANDIOR OMISSIONS.
<br /> 27, ALL EXISTING FIRE SPRINKLERS TO BE MODIFIED TO SERVICE MODIFIED SPACES, BUILDING SUMMARY PROJECT TEAM CONTENT OF WORKING DRAWINGS ARE TO BE VERIFIED PRIOR
<br /> TO CONSTRUCTION BY CONTRACTOR.WRITTEN DIMENSIONS
<br /> 28. ALL HARDWARE TO BE ADA COMPLIANT AND MATCH EXISTING BUILDING STANDARD. A.B. ANCHOR BOLT ELEV. ELEVATION OR ELEVATOR L.L. LIVE LOAD RED. REQUIRED HAVE PRECEDENCE OVER SCALED.
<br /> A.C.P. ACOUSTICAL CEILING PANEL ENCL. ENCLOSURE L.PT. LOW POINT REV. REVISION
<br /> 29. ALL NEW LIGHTING TO BE LED. A.C.T. ACOUSTICAL CEILING TILE ED. EQUAL LAB. LABORATORY RM. ROOM 1.PROJECT ADDRESS: TENANT:
<br /> A.F.F. ABOVE FINISH FLOOR EQPT. EQUIPMENT LAM. LAMINATE RTD. RATED ACCESS LASER Access Laser ISSUANCE
<br /> A.P.C. ACOUSTICAL PANEL CEILING EXH, EXHAUST LAV. LAVATORY 2211 W,CASINO ROAD,UNIT At 2211 W,Casino Road,Unit Al
<br /> _ A.T. ACOUSTICAL TILE EXST, EXISTING LB. POUND S.C. SOLOCORE EVERETT,WA 98204 Everett,WA 98204
<br /> APPROVED This approval only applies to ACOUS.ACOUSTICAL EXP. EXPANSION BL. LABEL S.D. SMOKE DETECTOR TEL: 425-5122-2844
<br /> ADJ. ADJACENT EXT. EXTERIOR LOC. LOCATION S.F. SQUARE FEET ATTN: John Buskirk
<br /> _ Officeof Community,Planning&Economic Development the work being performed under ADJST. ADJUSTABLE LVR. LOUVER B.S. STAINLESS STEEL 2.APPLICABLE CODES&ORDINANCES: EMAIL:jbuskirk@accesslaseccom
<br /> PLANNING DEPARTMENT Permit g62303-069 ALT. ALTERNATE F.B. FLAT BAR S.V. SHEET VINYL 20181NTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS
<br /> NAME: Jessica larvi and does not recognize an AL. ALUMINUM F.D. FLOOR DRAIN M.D.F. MEDIUM DENSITY FIBERBOARD S.Y. SQUARE YARDS ICC/ANSI At 17A_09,ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES,WITH STATEWIDE AMENDMENTS ARC HITECTIDESIGNER:
<br /> g Y AN. ANODIZED F.E. FIRE EXTINGUISHER M.D.O. MEDIUM DENSITY OVERLAY SCHED.SCHEDULE 2018 INTERNATIONAL RESIDENTIAL CODE WITH STATEWIDE AMENDMENTS Point OlVision
<br /> DATE: 09/11/2023 existing structure that may not APPROX. APPROXIMATELY F.E.C. FIRE EXTINGUISHER CABINET M.E. MATCH EXISTING SCR. SCREEN 20181NTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 162846th Street BE
<br /> ARCH. ARCHITECTURAL F.F. FACTORY FINISH M.H. MANHOLE SECT. SECTION Everett,WA
<br /> meet Zoning Code. ASS, ASSEMBLY F.F.E. FINISH FLOOR ELEVATION M.O. MASONRY OPENING SH. SHELF 20181NTERNATI0 AL FUEL GAS CODE WITH STATEWIDE AMENDMENTS(PART OF THE IMC ADOPTION) TEL 425-772-8207
<br /> AN AUDIO VISUAL F.F.W. FINISH FACE OF WALL MACH. MACHINE SH.&P. SHELF AND POLE 2018 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS ATTN.Bob Bozonh
<br /> F.1.0. FURNISHED AND INSTALLED BY MATL. MATERIAL SHT. SHEET 2018 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS EMAIL:bob.bozontr&omcast.net
<br /> B.O.C. BOTTOM OF STRUCTURE OWNER MAX. MAXIMUM SHTH. SHEATHING 2018 INTERNATIONAL ENERGY CONSERVATION CODEMASHINGTON STATE ENERGY CODE UBI:604-144-967
<br /> B.P. BU IL BUI T-UP OF. FACE OF FINISH ME CH. MECHANICAL SIM. SIMILAR LDING STANDARD F.O. FACE OF MBR. MEMBER SHWR. SHOWER
<br /> B.0. 2018 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC GENERAL CONTRACTOR:
<br /> F
<br /> BD. BOARD F..O..LC. FURNISHED BY OWNER, MEMB. MEMBRANE St. SLOPE NATIONAL ELECTRICAL CODE(NFPA 70) Owner
<br /> BTWN. BETWEEN INSTALLED BY CONTRACTOR MEZZ. MEZZANINE SPEC. SPECIFICATION Access Laser
<br /> _ BLDG. BUILDING F.T.I.C. FURNISHED BY TENANT, MIN. MINIMUM SPKLR. SPRINKLER 3.GENERAL BUILDING DESCRIPTION: 2211 W,Casino Road,Unit Al
<br /> BILK. BLOCK INSTALLED BY CONTRACTOR MFR, MANUFACTURER SPKR. SPEAKER TYPE OF CONSTRUCTION:-IIS Everett,WA 98204
<br /> I BLKG. BLOCKING F.U. FIREPROOF MN. MINIMUM SQ. SQUARE FIRE RESISTIVE SYSTEM:SPRINKLERED WITHOUT QUICK RESPONSE HEADS TEL 425-5122-2844
<br /> BM. BEAM F.R. FIRE RESISTIVE MRR. MIRROR STD. STANDARD OCCUPANCY TYPE:'B'OFFICE I'F1'FACTORY ATTN: John Buskirk
<br /> BOT. BOTTOM F.R.P. FIBERGLASS-REINFORCED PANELMISC. MISCELLANEOUS STL. STEEL EMAIL:jbuskirk@accesslaseccom
<br /> BRKT. BRACKET F.S. FULL SIZE MTD. MOUNTED STN. STAIN q,BUILDING INFO::
<br /> FDN. FOUNDATION MTG. MOUNTING $TOR. STORAGE
<br /> C.B. CATCH BASIN FIN. FINISH MTL. METAL STRUC.STRUCTURAL BUILDING AREA: FLOOR 1-29,230 SQUARE FEET PROJECT INFORMATION
<br /> C.F. CUBIC FEET OR FOOT FIXT. FIXTURE MULL. MULLION SURR, SURROUND FLOOR 2.6,596 SQUARE FEET
<br /> C.L. CENTERLINE FLASH FLASHING SUSP. SUSPENDED PROJECT NO: POV2327
<br /> C.M.A. CONCRETE MASONRY UNITS FLOG. FOLDING N. NEW SYMM. SYMMETRICAL S.PRQIEQT GE$QRIPTIQN: LEGAL DESCRIPTION 1 PARCEL NO. PROJECT MANAGER: BB
<br /> C.T. CERAMIC TILE FLR. FLOOR N.I.C. NOT IN CONTRACT SYS. SYSTEM INSTALLATION OF OF ENCLOSING BACKSIDE OF FACILITY
<br /> C.Y. CUBIC YARD(S) FLUOR.FLUORESCENT N.T.S. NOTTOSCALE DRAWN BY' BB
<br /> CAB. CABINET FR. FRAME OR FRAMING NO. NUMBER T. TREAD PARCEL NUMBER: 28041400200900
<br /> - CENT. CEMENT FT. FOT OR ING N/A NOMINAL T.A. TOILETACCESSORY
<br /> DETERMINED
<br /> DEFINITIONS AND DIMENSIONS
<br /> CER. CERAMIC FT. FOOTING NIA NOT APPLICABLE T.B.D. TO BE DETERMINED LEGAL DESCRIPTION:
<br /> - CLG. CEILING FURR. FURRING TAG. TONGUE AND GROOVE THE LAND REFERRED TO IS SITUATED IN THE COUNTY OF SNOHOMISH,CITY OF EVERETT,STATE OF
<br /> CLKG. CAULKING FUT. FUTURE O.C. OVERALL T.B. TACK BOARD WASHINGTON,AND IS DESCRIBED AS FOLLOWS:
<br /> CUR. CLEAR O.C. ON CENTER T.O. TOP OF A.DEFINITIONS: THAT PORTION OF THE NORTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 14,
<br /> CNTR. COUNTER G.B. GRAB BAR O.H. OVERHEAD TO TOP OF CURB OR CONCRETE TOWNSHIP 28 NORTH,RANGE 4 EAST,W.M.IN SNOHOMISH COUNTY,WASHINGTON,DESCRIBED
<br /> COL. COLUMN G.C. GENERAL CONTRACTOR O.L. OCCUPANTLOAD T.O.S. TOPOF SLAB ORTOPOFSTEEL 1.7YPICAL"OR'TYP'INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. AS FOLLOWS:
<br /> COMP. COMPOSITION G.L.R. GLU-LAM BEAM O.S.B. ORIENTED STRANDBOARD T.O.P. TOP OF PAVEMENT BEGINNING AT THE NORTH ONE-QUARTER CORNER OF SAID SECTION 14;
<br /> CONIC. CONCRETE GWB GYPSUM WALLBOARD 0/ OVER T.O.W. TOP OF WALL 2."SIMILAR"OR"SIM."INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE
<br /> COND, CONDITION GA. GAUGE OBS. OBSCURE T.S. TUBE STEEL CONDITION NOTED. AND PROCEEDING THENCE ALONG THE NORTH LINE OF SAID SECTION NORTH 87°54'56"WEST
<br /> CONE. CONFERENCE GALV. GALVANIZED OCC. OCCUPANT T.V. TELEVISION 769.83 FEET;THENCE SOUTH 00"49'33"WEST 30.01 FEET TO THE SOUTHERLY MARGIN OF THE
<br /> CONN. CONNECTION GL. GLASS OFF. OFFICE TEL. TELEPHONE 3."AS REQUIRED"INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS COUNTY ROAD,WHICH POINT IS THE NORTHEAST CORNER OF THE TRACT HEREIN DESCRIBED AND
<br /> -- CONSTR. CONSTRUCTION GND. GROUND OP. OPERABLE TEMP. TEMPERED OR TEMPORARY INDICATED IN THE PROJECT DOCUMENTS THE TRUE POINT OF BEGINNING;THENCE SOUTH 00'49'33"WEST 635.04 FEET;
<br /> CONT. CONTINUOUS GP. GROUP OPNG. OPENING THK. .THICK THENCE NORTH 87'54'56'WEST 205.0 FEET;
<br /> CONTR.CONTRACTOR GR. GRADE OPP. OPPOSITE TLT. TOILET 4.'ALIGN'INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT,TRUE,AND PLUMB RELATION THENCE NORTH 00°49'33"EAST 635.04 FEET;
<br /> 3}6 _•u..,.zw CORR. CORRIDOR CORRUGATED GYP. GYPSUM OVHD. OVERHEAD THR. THRESHOLD ADJACENT MATERIALS.
<br /> CPT. CARPET TYP. TYPICAL THENCE ALONG THE SOUTHERLY MARGIN OF THE COUNTY ROAD SOUTH 870 54'56"EAST 205.0 TO
<br /> CTR. CENTER H. HIGH P. PAINT THE TRUE POI NT OF BEGINN ING;
<br /> CTSK. COUNTERSUNK H.A HANDICAP OR HOLLOW CORE PART. PARTITION U.L. UNDERWRITERS LABORATORIES 5."CLEAR'INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS.
<br /> H.M. HOLLOW METAL PBD. PARTICLEBOARD U.O.N. UNLESS OTHERWISE NOTED EXCEPT PORTION CONVEYED TO STATE OF WASHINGTON FOR HIGHWAY BY DEED UNDER
<br /> D. DEEP OR DEPTH H.R. HAND RAIL PC. PIECE U.P.S. UNINTERUPTED POWER SUPPLY B.DIMENSIONS: RECORDING NO.2011159.
<br /> D.A. DOUBLE ACTING H.W.T. HOT WATER TANK PERE PERFORATED UNF. UNFINISHED
<br /> D.F. DRINKING FOUNTAIN HBD. HARDBOARD PERP. PERPENDICULAR UR, URINAL 1.DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION,CENTER OF SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON
<br /> - D.P. DAMPPROOFING HDR. HEADER PL. PLATE COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED.
<br /> D.W. DISHWASHER HOW. HARDWARE PLAM. PLASTIC LAMINATE V.B. VAPOR BARRIER
<br /> p /�T �• DBL. DOUBLE HORIZ. HORIZONTAL PLAS. PLASTER V.C.A. VINYL COMPOSITION TILE 2.ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT,TRUE&PLUMB.DIMENSIONAL LAYOUT
<br /> \PfIOJ EIS I SITE E DEC. DECORATIVE HR. HOUR PLBG. PLUMBING V.G. VERTICAL GRAIN SHALL BE IN THE FOLLOWING PRIORITY ORDER. DRAWING INDEX
<br /> DEMO. DEMOLISH OR DEMOLITION HT. HEIGHT PLYWD.PLYWOOD V.I.F. VERIFY IN FIELD A.STRUCTURAL DRAWINGS
<br /> DEPT. DEPARTMENT HWD. HARDWOOD PNL. PANEL V.W.C. VINYL WALL COVERING B.LARGE SCALE DETAILS
<br /> - DIA. DIAMETER PR. PAIR VERT. VERTICAL C.SMALL SCALE DETAILS DRAW ING ISSUE Check Set 7/26/23
<br /> DIAG. DIAGONAL INCL. INCLUDED,INCLUDING PRCST.PRECAST VEST. VESTIBULE Q ENLARGED PLANS AND SECTIONS
<br /> DIFF. DIFFUSER INFO. INFORMATION PT. PAINT OR POINT E.FLOOR PLANS
<br /> DIM. DIMENSION INSUL. INSULATION PTN. PARTITION W. WIDE
<br /> DISP. DISPENSER INT. INTEGRAL INTERIOR W.A. WATER CLOSET 3.MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. w
<br /> ON. DOWN OTY. QUANITY W.H. WATER HEATER $ Cover Plan 1
<br /> DR. DOCUMENTS JAN. JANITOR W.P. WATERPROOF 4.FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB,UNLESS OTHERWISE NOTED.
<br /> DR. DOOR IT. JOIST R.) RELOCATE W.R. WATER RESISTANT Site Plan
<br /> DTL DETAIL IT. JOINT R. RISER W/ WITH
<br /> ' DWG. DRAWING R.D. RGHT HAND W/0 WITHOUT 5.VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL,UNLESS NOTED �
<br /> KD. KNOCK-OUT R.I.A. ROUGH-IN ONLY WD. WOOD ABOVE FINISH FLOOR-"AFF". SHEET NO
<br /> VICINITY MAP (E) EXISTING KIT. KITCHEN R.O. ROUGH OPENING WDW. WINDOW
<br /> E.W. ELECTRICAL PANEL RAG. RADIUS WT. WEIGHT 6.CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR ARCHITECTURAL I INTERIORS A1 .00
<br /> EA. EACH L.B. LAG BOLT REF. REFERENCE OR REFRIGERATOR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES,UNLESS OTHERWISE NOTED. % A1.00 COVER SHEET/SITE PLAN
<br /> NTS z EL. ELEVATION L.F. LINEAL FOOT REINF. REINFORCED OR REINFORCING
<br /> ELEC. ELECTRICAL L.H. LEFT HAND REL. RELOCATED 7.DOCUMENTS ARE DRAWN DIAGRAMMATICALLY,AND SCALED DIMENSIONS ARE APPROXIMATE.DIMENSIONS SHALL
<br /> REM. REMOVE INDICATE REQUIRED SIZE,CLEARANCES,AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED.
<br />
|