Laserfiche WebLink
: Morrison Hershfield 02/03/2023 <br /> ICompany <br /> IRIS& Designer : VG 9:57:18AM <br /> Job Number DSH-062R1 /2204047 Checked By : YW <br /> Model Name : Site#: SESEA00380C/ KOZ APARTMENTS <br /> Model Settings(Continued) <br /> Stiffness Adjustment Yes (Iterative) <br /> Compression Stress Block Rectangular Stress Block <br /> Analyze using Cracked Sections Yes <br /> Leave room for horizontal rebar splices (2*d bar spacing) Yes <br /> List forces which were ignored for design in the Detail Report Yes <br /> Column Min Steel 1 <br /> Column Max Steel 8 <br /> Rebar Material Spec ASTM A615 <br /> Warn if beam-column framing arrangement is not understood No <br /> Number of Shear Regions 4 <br /> Region 2 &3 Spacing Increase Increment(in) 4 <br /> Code ASCE 7-16 <br /> Risk Category I or II <br /> Drift Cat Other <br /> Base Elevation (ft) <br /> Include the weight of the structure in base shear calcs Yes <br /> S, (q) 0.426 <br /> SD, (q) 0.532 <br /> SDS(q) 0.958 <br /> TL(sec) 6 <br /> T Z(sec) <br /> T X(sec) <br /> CZ 0.02 <br /> C,X 0.02 <br /> C,Exp. Z 0.75 <br /> C,Exp. X 0.75 <br /> RZ 3 <br /> RX 3 <br /> S)oZ 2 <br /> QOX 2 <br /> CdZ 4 <br /> CdX 4 <br /> RISA-3D Version 20 [FRP Enclosed Antenna Mounts-Alpha.r3d] Page 2 <br />