Laserfiche WebLink
16 of 23 <br /> Project Number: Plan Name: Sheet Number: <br /> S230130-2XR 5117 23rd Ave W <br /> Engineer: Subject: Date: <br /> PAM 26"Unreinforced Conc Beam 3/17/2023 <br /> DEMAND CALCULATION <br /> number of stories R 2 stories <br /> span L 6.0 ft [max on-center pile spacing] <br /> concrete area A 216 in2 'see attached <br /> concrete self weight 5W 225 plf [Includes total height w/o ACI14 414.5.1.7 redux] <br /> w Ol DL 780 plf [2-story loading] <br /> wil LL 960 plf [2-story loading] <br /> w LLr LLr 300 plf [2-story loading] <br /> "Assuming a single span between 2 piles-in reality continuous spans between piles will have reduced moments" <br /> moment from OL Mot 4,523 lb-ft 54.3 k-in <br /> moment from LL M„ 4,320 lb-ft 51.8 k-in Mmax=gwL2 <br /> moment from SL M,u 1,350 lb-ft 16.2 k-in <br /> shear from OL Vo, 3,015 lb 3.02 k <br /> shear from LL V„ 2,880 lb 2.88k Vnnx=Zwt. <br /> shear from SL V,,, 900 lb 0.90 k <br /> factored moment M,gro 76.0 k-in 1.4DL <br /> M,gro 156.2 k-in 1.2DL+1.6LL+0.SSL <br /> M:rr. 142.9 k-in 1.2DL+1.6SL+LL <br /> controlling factored moment M„ 156.2 k-in <br /> factored shear Vur5 4.2k 1.4DL <br /> V,,,ro 8.7 k 1.2DL+1.6LL+0.5SL <br /> V,,,ra 7.9 k 1.2DL+1.69.+LL <br /> controlling factored shear V„ 8.7 k <br /> controlling factored bearing 8„ 8.7 k Bmax=Vmrrx • <br /> STRENGTH CALCULATION <br /> concrete strength fc 2.5 ksi assumed <br /> light wt concrete mod.factor h 1 normal weight concrete <br /> flexure strength red.factor fin,. 0.6 ACI 318-14[Table 21.2.11 <br /> shear strength red.factor rb,n,,, 0.6 ACI 318-14[Table 21.2.1] <br /> bearing strength red.factor 4,,,,,,„g 0.6 ACI 318-14[Table 21.2.1] <br /> "Note that per ACI 318-14 Ch.27.3.2 a phi factor of 0.8 can be used if dimensions and material properties ore confirmed. <br /> moment of ineritia Ia 11,016 in4 "see attached <br /> elastic section modulus Sr, 1,001 in3 "see attached <br /> tens fiber to NA c 13.0 in "see attached <br /> nom flexure strength(T controls) M„ 250.3 k-in ,Mn=52 Sm CONTROLS ACI 318-14[Eq.14.5.2.1a] <br /> nom flexure strength(C controls) M, 2,127.1 k-in ,ti,—0.85/;'S,„ ACI 318-14[Eq.14.5.2.1b] <br /> RESIDENTIAL CONCRETE M„ 375.4 k-in Mn=7.55ASm X ACI 332-14[Eq.8.2.1.1] -not utilized <br /> flexure strength 4aM„ 150.2 k-in <Mu FAILED D/C=104.01% <br /> Calculation based on single span. <br /> nom shear strength V. 14.4 k V„=4 d .A AC114[Table 14.5.5.1(a)] Multiple spans increase strength, <br /> 3 therefore within 5/a is acceptable. <br /> shear strength r0V„ 8.6k <Vu FAILED D/C=100.42% <br /> loaded bearing area A. 74 n2 [IDEAL 2-7/8"Tru-Force Underpinning Bracket] <br /> supporting surface bearing area A, 74 in2 [If the supporting surface is>than loaded area] <br /> nom bearing strength B. 156,6k 0.85f'A, ACI14(Table 14.5.6.1(c)] <br /> bearing strength GB„ 94.0 k >Bu OK D/C=9.23% <br /> Additional Verification Cale: <br /> max concrete tensile strength f, 375 psi 1=7,5A ACI 318-14[Eq.19.2.3.1] <br /> max beam tensile stress F, 184 psi Fr=(M"c,/Iss <br /> f, >Ft OK <br />