My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5117 23RD AVE W 2018-01-02 MF Import
>
Address Records
>
23RD AVE W
>
5117
>
5117 23RD AVE W 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2025 2:54:37 PM
Creation date
3/21/2025 9:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD AVE W
Street Number
5117
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 of 23 <br /> A PROJECT NO. SHEET NO. <br /> S230130-2XR <br /> %11%.1110 5117 23rd Ave W, Everett, WA <br /> PROJECT <br /> LONGITUDE SUBJECT Foundation Stabilization <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY PAM DATE 03/17/23 <br /> Scope/Objective: <br /> To determine the required pile spacing and geometry to stabilize the existing structural foundation. These findings have been based <br /> upon the calculated strength of the existing foundation system and the current vertical loading from the existing structure above(based <br /> on as-built assessments). <br /> The R&R Foundation Specialists'(R&R)proposed pile layout can be found in the following pages with structural recommendations <br /> based upon the findings of L120 Engineering&Design. <br /> Note that cosmetic damages to rigid wall coverings/members and siding are expected during a foundation lift. Such cosmetic <br /> damages/cracks are to be repaired by others following the completion of the foundation stabilization and lifting and are not included in <br /> the structural scope presented here. <br /> It should be further noted that L120's scope is limited to the perimeter support systems/continuous footings.The interior crawl-space <br /> support system for the first floor shall be installed per R&R. This could include the use of some or all of the following:longer support <br /> posts,adjustable post-base hardware,and/or the addition of taller wood support members. Settlement in these interior support areas <br /> shall be monitored and further adjustments shall be made if necessary. <br /> Structural Summary: <br /> -The foundation of the residence consists of continuous cast-in-place concrete stem wall and concrete strip footings.Below the footings, <br /> piles are to be spaced at a distance no larger than 6'-0"on-center at the locations indicated on the attached Level Survey.Piles to be <br /> installed in accordance with SSK-01. <br /> -End piles are to be placed as close to corners as possible and shall not exceed a max corner offset distance of 1'-0". <br /> -A maximum allowable loading of 2,300 plf was utilized in this analysis.This was determined through inspection of building geometry <br /> and conservative span/tributary loading assumptions based on standard construction practices <br /> - The following load values represent the maximum expected pile loads for the indicated spacing. R&R to provide pile and equipment <br /> assemblies with capacities equal to or greater than the indicated load values. <br /> Allowable Load Capacity Requirement: <br /> Piles 1-4 14 kip minimum vertical capacity(allowable load) <br /> Piles 5-6 29 kip minimum vertical capacity(allowable load) <br /> Piles 7-8 11 kip minimum vertical capacity(allowable load) <br /> Note: Refer to the attached General Notes for additional requirements. <br /> - As determined by R&R,the site appears to have no lateral(horizontal)displacements or concerns. As such,the analysis and <br /> recommendations presented in this report have been strictly limited to vertical stabilization/jacking. If lateral movement is observed or <br /> expected additional structural analysis will be required. <br /> - Structural recommendations contained in this package are based on site photographs dated January 26,2023, provided by R&R.To <br /> the knowledge of L120,a geotechnical investigation was not performed on this site.Consequently,all structural recommendations <br /> assume adequate soil conditions to obtain the required pile capacities. <br /> Please inform L120 of site-specific conditions that were unconsidered by,may conflict with,or otherwise compromise the <br /> recommendations contained within this package,including,but not limited to,water drainage,slope stability,existing structural damage, <br /> or existing subsurface obstructions. In this instance,the structural assumptions,recommendations,and scope for this project will need <br /> to be revisited to consider and address the new findings <br /> Refer to the following pages for pile and connection specifications. <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.