Laserfiche WebLink
I HEINTZ-YEAGER RESIDENCE I February 21, 2023 I SDA Job# 9684A I 4 <br /> SEISMIC DISTRIBUTION FOR:A15-WSW.R=6.5 <br /> 1) EV height EV x height REDISTRIBUTE: E() <br /> EV(ROOF)= 7966 lb 33 262864 lb 11175 lb <br /> IV(2ND FLOOR)= 7024 lb 19 133451 lb EV x height x IV TOTAL = 5673 lb <br /> IV(1ST FLOOR)= 3232 lb 10 32318 lb IV x height TOTAL 1373 lb <br /> EV()= lb lb <br /> BASE SHEAR= 18221 lb 428633 lb <br /> SEISMIC DISTRIBUTION FOR:G6-TF.R=1.5 <br /> 2) EV height IV x height REDISTRIBUTE: E() <br /> IV(ROOF)= 34518 lb 33 1139078 lb 48422 lb <br /> EV(2ND FLOOR)= 30436 lb 19 578286 lb EV x height x IV TOTAL = 24583 lb <br /> EV(1ST FLOOR)= 14004 lb 10 140045 lb EV x height TOTAL 5953 lb _ <br /> EVO= lb lb <br /> BASE SHEAR= 78958 lb 1857408 lb <br /> BASE SHEAR= <br /> BASE SHEAR= <br /> UNFACTORED LOAD SUMMARY: <br /> LEVEL WIND SEISMIC <br /> (Ft-Rr) I (Lt-Rr) A15-WSW I G6-TF <br /> EV(Roof)= 11378 lbs 7985 lbs 11175 lbs 48422 lb <br /> EV(3rd Floor)= 11601 lbs 11161 lbs 5673 lbs 24583 lb <br /> EV(2nd Floor)= 9115 lbs 10461 lbs 1373 lbs 5953 lb <br /> NOT APPLICABLE lb <br /> TOTAL BASE SHEAR= 32094 lbs 29607 lbs 18221 lbs 78958 lb <br />