/Pip '7 . y%%tip 1 <br /> �Prt)ject Title; TerraPower-TI-2018 WSEC ��ate ',fit <br /> ,r; U x A Calculation CHANGE IN SPACE CONDITIONING-FULLY CONDITIONED e COMPLIES <br /> Opaque Envelope Assemblies PROPOSED TARGET <br /> Roof/Ceiling Roof/Ceiling ( <br /> Roof/Ceiling Assembly ID Assembly U- Net Area(SF) U x A . Assembly U S Net Area(SF) 1 U x A 1 <br /> Factor Factor <br /> 1 <br /> Attic and other Suspended Insulation grid 0.032 2,648.0 84.7 0.021 2 648.0 <br /> Wall Wall <br /> Walls Assembly ID Assembly U- Net Area(SF) U x A Assembly U- Net Area(SF) U x A <br /> factor factor <br /> Steel-framed-Commercial warehouse wall 6"metal stud wall-upto 16ft 0.069 1,344.0 92.7 ? 0.055 1,344.0 <br /> (1) _,,, <br /> Steel-framed-Commercial Existing demising wall 0.106 515.0 54.6 0.055 515.0 <br /> 1 <br /> 32 <br /> Mass(precast concrete)-Commercial upto 12'-6"-(3.5"metal furring @ 24"O.C) 0.090 1,232.0 110.9 0.104 1'(I)'0 128.1 <br /> __. 446.0 <br /> 1 Mass(precast concrete)-Commercial furring on pins-12'-6"to 16 0.045 446.0 20 1 0.104 t (1) 46 4 <br /> Slab on Grade Floors PROPOSED TARGET <br /> Slab-on-grade Floors Assembly ID F-Factor Perimeter Length U x A F-Factor Perimeter Length u x A <br /> (LF) 1 (LF) <br /> Unheated slab existing 0.73 142.0 103.7 0.54 142.0 <br /> Fenestration and Opaque Door Assemblies ..,r PROPOSED TARGET <br /> -_ .1 <br /> oor <br /> or <br /> Opaque Doors Assembly ID Assembly U- Rough Opening U x A Assembly U- Rough Opening U x A <br /> Factor (S� Factor l (SF) <br /> Swinging doors opening to warehouse 0.37 72.0 26.6 0.37 , �1) 26.6 <br /> Fenestration , Fenestration € , <br /> Vertical Fenestration Assembly ID Assembly U- Roug(Opening U x A Assembly U- Rough Opening U x A 1 <br /> Factor Factor i • <br /> 564.0 <br /> Fixed-Class AW or site built Existing Windows 0.38 564.0 214.3 0.38 (1) :iL 214.3*i <br /> Glazed Doors Assembly ID Assembly U- Rough Opening U a A Assembly U-' Rough Opening U x A <br /> Factor (SF) Factor (SF) <br /> e <br /> Swinging entrance door Existing Storefront 0.6 21.0 12.6 0.60 € ��'' 12.6 <br /> . <br /> Proposed Area Proposed UxA i Target Area Target UxA i Target UxA with Adjustment <br /> 63 <br /> e Project TotalsL 6,984 720 1 6,984 60 <br /> NOTE:Change in space conditioning or occupancy allowance applied-1.10 multiplier has been applied to the Total Target UxA for exterior areas only.Refer to Target UxA with Adjustment. <br /> 3i4 <br />