My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY REDWOOD 2025-04-07
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
REDWOOD
>
906 SE EVERETT MALL WAY REDWOOD 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 2:13:59 PM
Creation date
3/24/2025 9:35:51 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
REDWOOD
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESSIBLE ROUTE NOTES EXITING NOTES EXITING LEGEND <br /> 1. INTERIOR FLOOR SURFACE AND EXTERIOR ACCESSIBLE ROUTE m x a <br /> 1. CONSTRUCTION TYPE:II-FR 13.ATACTILE SIGN STATING EXIT IN RAISED CHARACTERS AND BRAILLEAND COMPLYING WITH <br /> SHALL BE STABLE,FIRM AND SLIP RESISTANT w F E <br /> 2. SPRINKLERS:NONSPRINKLERED (PER IBC 1013.4). <br /> ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR LEADING TO THE EXIT DISCHARGE. INDICATES THE NUMBER OF �- <br /> s w s <br /> 2. THRESHOLDS AT DOORS SHALL BE BEVELED AND NOT MORE # OCCUPANTS AT EACH EXIT a <br /> THAN 112"IN HEIGHT a m 3 <br /> 3. EXISTING EMERGENCY VOICEIALARM COMMUNICATION SYSTEM TO REMAIN.CONTRACTOR 14,THE MEANS OF EGRESS,INCLUDING THE EXIT DISCHARGE,SHALL BE ILLUMINATED AT ALL <br /> 3. NO SLOPE SHALL EXCEED 1:48 ALONG THE ACCESSIBLE ROUTE <br /> SHALL MODIFY AS NECESSARY FOR NEW SPACES.MODIFICATIONS NOT SHOWN ON TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED.THE 3 <br /> w ARCHITECTURAL DRAWINGS;INCLUDED IN DEFERRED SUBMITTAL IF NECESSARY. ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE EXIT SIGN I DIRECTIONAL <br /> 4. MANEUVERING CLEARANCES SHALL BE PROVIDED AT DOORS LEVEL.(PER IBC 1008.2 AND 1008.2.1) **1 LIGHTING <br /> SIGN W/EMERGENCY RZ <br /> PERA117.1 SECTION 404 4. REQUIRED EXIT STAIRWAY WIDTH:0.3 INCHES PER OCCUPANT(PER SBC 1005.3.1).MINIMUM LIGHTING <br /> STAIR WIDTHS ARE SHOWN AT STAIRWAYS. 15.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION <br /> THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT- <br /> 5. REQUIRED EXIT DOOR WIDTH:0.2INCHES PER OCCUPANT(PER SEC 1005.3.2).MINIMUM DOOR CANDLE.(PER IBC 1008.3.5). <br /> WIDTHS ARE SHOWN AT EXIT. EMERGENCY LIGHTING <br /> 16.IN THE EVENT OF POWER FAILURE AN EMERGENCY ELECTRICAL SYSTEM SHALL <br /> 6. REQUIRED CORRIDOR WIDTH:0.15 INCHES PER OCCUPANT(PER IBC 1005.3.2.1) AUTOMATICALLY ILLUMINATE THE FOLLOWINGAREAS(PER IBC 1008.3.1): co <br /> MINIMUM 44 INCHES CLEAR CORRIDOR WIDTH REQUIRED(PER IBC 1020.2) - AISLES <br /> CORRIDORS <br /> O <br /> O O 7. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED.5"ABOVE THE FINISHED FLOOR OR - EXITACCESS STAIRWAYS �� COMMON PATH OF TRAVEL 3 co <br /> LANDING.(PER IBC 1010.1.7.) - VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT <br /> DISCHARGE Q <br /> 8. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE - ELECTRICAL EQUIPMENT ROOMS ce > <br /> OFA KEY ORANY SPECIAL KNOWLEDGE OR EFFORT.(PER IBC 1010.1.9.) - FIRE PUMP ROOMS ® 1HR RATED WALL W <br /> - GENERATOR ROOMS v O <br /> 9. DOOR HANDLES,PULLS,LATCHES,LOCKS,AND OTHER OPERATING DEVICES REQUIRED TO BE <br /> ACCESSIBLE BY CHAPTER 11 SHALL BE INSTALLED BETWEEN 34'AND 48"ABLOVE THE FLOOR 17,SEE REFLECTED CEILING PLANS FOR LOCATIONS OF EXIT SIGNS L.L_ 'n W <br /> SURFACE AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING OR TWISTING OF THE WRIST ) CC <br /> JJ TO OPERATE.(PER IBC 1010.1.9.1 AND 1010.1.9.2) 18.LENGTH OF DEAD END IN CORRIDOR SHALL NOT EXCEED 50 FEET ON THE SECOND FLOOR IS W <br /> I:I'� NCE.00M 7 <br /> OCCUPANCY).(PER IBC 1020.4.2) O W <br /> �'. <br /> r^ �-���� - ~ �-��� ---� � 10.EXIT AND EXIT ACCESS DOORS SHALL BE MARKED BYAN APPROVED EXIT SIGN READILY <br /> VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.EXIT SIGN PLACEMENT SHALL BE SUCH 19.CONTRACTOR SHALL FIELD VERIFY FIRE EXTINGUISHER LOCATIONS,NOT TO EXCEED 150' J = • <br /> THAT NO POINT IN AN EXIT ACCESS CORRIDOR IS MORE THAN 1 00'OR THE LISTED VIEWING APART AND PROVIDE NEW FIRE EXTINGUISHERS AS NECESSARY.CONTRACTOR SHALL VERIFY J } <br /> DISTANCE FOR THE SIGN,WHICHEVER IS LESS.(PER IBC 1013.1);EXIT SIGNS SHALL BE LOCATION WITH OWNER PRIOR TO INSTALLATION. Q <br /> 6-/ INTERNALLY OR EXTERNALLY ILLUMINATED. <br /> 11.MAXIMUM EXIT ACCESS TRAVEL DISTANCE: <br /> t \ t 136'FROM BREAK ROOM TO STAIR N0.2 � 'J <br /> (200 FT PERMITTED FOR Id PER SEC TABLE 1016.2.I4 IS MORE RESTRICTIVE THAN E.) m < <br /> l <br /> 12.PANIC HARDWARE IS PROVIDED ATALL OUT SWING EGRESS DOORS. LJJLu <br /> \ � Lu <br /> > W <br /> i > <br /> \\ t W W <br /> Lu <br /> O \ O O <br /> \\ tf d U a) <br /> \ "a4 tom/ <br /> Ln <br /> N <br /> u'1 <br /> n <br /> cc <br /> N <br /> \\\ ® W cc <br /> \ \ CO <br /> co <br /> \ t o <br /> W M <br /> U Wo <br /> o <br /> H- <br /> � U <br /> s H- <br /> w U_ 2 <br /> H Q ~ Q <br /> ® � J <br /> -- <br /> s l m un w <br /> uV) <br /> NO WORK IN SHADED AREA <br /> 9 <br /> STNR a <br /> Pj <br /> 9/10/24 <br /> N0.1 <br /> EXITING PLANS <br /> FIFTH FLOOR - SUITE 501 - EXITING PLAN N AO.3 <br /> A0.3 1/8" - 1,_0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.