Laserfiche WebLink
ACCESSIBLE ROUTE NOTES EXITING NOTES EXITING LEGEND <br /> 1. INTERIOR FLOOR SURFACE AND EXTERIOR ACCESSIBLE ROUTE m x a <br /> 1. CONSTRUCTION TYPE:II-FR 13.ATACTILE SIGN STATING EXIT IN RAISED CHARACTERS AND BRAILLEAND COMPLYING WITH <br /> SHALL BE STABLE,FIRM AND SLIP RESISTANT w F E <br /> 2. SPRINKLERS:NONSPRINKLERED (PER IBC 1013.4). <br /> ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR LEADING TO THE EXIT DISCHARGE. INDICATES THE NUMBER OF �- <br /> s w s <br /> 2. THRESHOLDS AT DOORS SHALL BE BEVELED AND NOT MORE # OCCUPANTS AT EACH EXIT a <br /> THAN 112"IN HEIGHT a m 3 <br /> 3. EXISTING EMERGENCY VOICEIALARM COMMUNICATION SYSTEM TO REMAIN.CONTRACTOR 14,THE MEANS OF EGRESS,INCLUDING THE EXIT DISCHARGE,SHALL BE ILLUMINATED AT ALL <br /> 3. NO SLOPE SHALL EXCEED 1:48 ALONG THE ACCESSIBLE ROUTE <br /> SHALL MODIFY AS NECESSARY FOR NEW SPACES.MODIFICATIONS NOT SHOWN ON TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED.THE 3 <br /> w ARCHITECTURAL DRAWINGS;INCLUDED IN DEFERRED SUBMITTAL IF NECESSARY. ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE EXIT SIGN I DIRECTIONAL <br /> 4. MANEUVERING CLEARANCES SHALL BE PROVIDED AT DOORS LEVEL.(PER IBC 1008.2 AND 1008.2.1) **1 LIGHTING <br /> SIGN W/EMERGENCY RZ <br /> PERA117.1 SECTION 404 4. REQUIRED EXIT STAIRWAY WIDTH:0.3 INCHES PER OCCUPANT(PER SBC 1005.3.1).MINIMUM LIGHTING <br /> STAIR WIDTHS ARE SHOWN AT STAIRWAYS. 15.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION <br /> THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT- <br /> 5. REQUIRED EXIT DOOR WIDTH:0.2INCHES PER OCCUPANT(PER SEC 1005.3.2).MINIMUM DOOR CANDLE.(PER IBC 1008.3.5). <br /> WIDTHS ARE SHOWN AT EXIT. EMERGENCY LIGHTING <br /> 16.IN THE EVENT OF POWER FAILURE AN EMERGENCY ELECTRICAL SYSTEM SHALL <br /> 6. REQUIRED CORRIDOR WIDTH:0.15 INCHES PER OCCUPANT(PER IBC 1005.3.2.1) AUTOMATICALLY ILLUMINATE THE FOLLOWINGAREAS(PER IBC 1008.3.1): co <br /> MINIMUM 44 INCHES CLEAR CORRIDOR WIDTH REQUIRED(PER IBC 1020.2) - AISLES <br /> CORRIDORS <br /> O <br /> O O 7. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED.5"ABOVE THE FINISHED FLOOR OR - EXITACCESS STAIRWAYS �� COMMON PATH OF TRAVEL 3 co <br /> LANDING.(PER IBC 1010.1.7.) - VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT <br /> DISCHARGE Q <br /> 8. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE - ELECTRICAL EQUIPMENT ROOMS ce > <br /> OFA KEY ORANY SPECIAL KNOWLEDGE OR EFFORT.(PER IBC 1010.1.9.) - FIRE PUMP ROOMS ® 1HR RATED WALL W <br /> - GENERATOR ROOMS v O <br /> 9. DOOR HANDLES,PULLS,LATCHES,LOCKS,AND OTHER OPERATING DEVICES REQUIRED TO BE <br /> ACCESSIBLE BY CHAPTER 11 SHALL BE INSTALLED BETWEEN 34'AND 48"ABLOVE THE FLOOR 17,SEE REFLECTED CEILING PLANS FOR LOCATIONS OF EXIT SIGNS L.L_ 'n W <br /> SURFACE AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING OR TWISTING OF THE WRIST ) CC <br /> JJ TO OPERATE.(PER IBC 1010.1.9.1 AND 1010.1.9.2) 18.LENGTH OF DEAD END IN CORRIDOR SHALL NOT EXCEED 50 FEET ON THE SECOND FLOOR IS W <br /> I:I'� NCE.00M 7 <br /> OCCUPANCY).(PER IBC 1020.4.2) O W <br /> �'. <br /> r^ �-���� - ~ �-��� ---� � 10.EXIT AND EXIT ACCESS DOORS SHALL BE MARKED BYAN APPROVED EXIT SIGN READILY <br /> VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.EXIT SIGN PLACEMENT SHALL BE SUCH 19.CONTRACTOR SHALL FIELD VERIFY FIRE EXTINGUISHER LOCATIONS,NOT TO EXCEED 150' J = • <br /> THAT NO POINT IN AN EXIT ACCESS CORRIDOR IS MORE THAN 1 00'OR THE LISTED VIEWING APART AND PROVIDE NEW FIRE EXTINGUISHERS AS NECESSARY.CONTRACTOR SHALL VERIFY J } <br /> DISTANCE FOR THE SIGN,WHICHEVER IS LESS.(PER IBC 1013.1);EXIT SIGNS SHALL BE LOCATION WITH OWNER PRIOR TO INSTALLATION. Q <br /> 6-/ INTERNALLY OR EXTERNALLY ILLUMINATED. <br /> 11.MAXIMUM EXIT ACCESS TRAVEL DISTANCE: <br /> t \ t 136'FROM BREAK ROOM TO STAIR N0.2 � 'J <br /> (200 FT PERMITTED FOR Id PER SEC TABLE 1016.2.I4 IS MORE RESTRICTIVE THAN E.) m < <br /> l <br /> 12.PANIC HARDWARE IS PROVIDED ATALL OUT SWING EGRESS DOORS. LJJLu <br /> \ � Lu <br /> > W <br /> i > <br /> \\ t W W <br /> Lu <br /> O \ O O <br /> \\ tf d U a) <br /> \ "a4 tom/ <br /> Ln <br /> N <br /> u'1 <br /> n <br /> cc <br /> N <br /> \\\ ® W cc <br /> \ \ CO <br /> co <br /> \ t o <br /> W M <br /> U Wo <br /> o <br /> H- <br /> � U <br /> s H- <br /> w U_ 2 <br /> H Q ~ Q <br /> ® � J <br /> -- <br /> s l m un w <br /> uV) <br /> NO WORK IN SHADED AREA <br /> 9 <br /> STNR a <br /> Pj <br /> 9/10/24 <br /> N0.1 <br /> EXITING PLANS <br /> FIFTH FLOOR - SUITE 501 - EXITING PLAN N AO.3 <br /> A0.3 1/8" - 1,_0 <br />