GENERALNOTES PROJECT TEAM PROJECT DATA <br /> GENERAL CONSTRUCTION PLUMBING,MECHANICAL,&ELECTRICAL TENANT POSTAL PLUS PROJECT ADDRESS: 7705 EVERGREEN WAY <br /> 7705 EVERGREEN WAY,SUITE G-07 STE G-07 <br /> 1.ALL CONSTRUCTION SHALL COMPLY WITH THE 2021 INTERNATIONAL BUILDING CODE AS ADOPTED BY 1.PLUMBING,MECHANICAL,AND ELECTRICAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE EVERETT,WA 98203 EVERETT,WA 98203 d i I I fames architecture <br /> THE CITY OF EVERETT,STATE REGULATIONS FOR BARRIER FREE DESIGN,WASHINGTON STATE PERMIT. CONTACT:HUAN NGUYEN <br /> ENERGY CODE,AND ALL APPLICABLE LOCAL CODES,ORDINANCES,AND STANDARDS.IN CASE OF ANY PHONE:360.390.1281 JURISDICTION: CITY OF EVERETT <br /> CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO 2.MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE EMAIL:HUANNG86@GMAIL.COM <br /> NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES,THE LAWS OR WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS. PARCEL NUMBER: 28050700306700 Postal Plus T ORDINANCES SHALL GOVERN.NOTIFY THE ARCHITECT OF ALL CONFLICTS. <br /> 3.MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/BUILD.THE CONTRACTOR SHALL ARCHITECT DILLJAMES ARCHITECTURE,LLC LEGAL DESCRIPTION: SEC 07 TWP 28 RGE 05TRACT 1 OF BSP REC VOL 1 OF <br /> 2.SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE,CONSTRUCTION,LABOR, BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK.THE PROPOSED 1417 NW 54TH ST,SUITE 311 BSPS PGS 196-198 AF NO 8912085005 BEING A PTN OF <br /> HEALTH AND LICENSING.CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL SYSTEM DESIGN AND METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED SEATTLE,WA 98107 SE1/4 NW1/4&A PTN OF NE1/4 SW1/4 <br /> INSURANCE REQUIRED BY LAW OR CONTRACT,FORWARDING PROOF OF SUCH ACTIONS TO THE BY THE OWNER PRIOR TO THE START OF ANY WORK. CONTACT:DILLON GOGARTY <br /> OWNER PRIOR TO COMMENCEMENT OF CONSTRUCTION. PHONE:509.690.8668 ZONING: B(BUSINESS) <br /> 4.WHERE APPLICABLE,STRUCTURAL,PLUMBING,MECHANICAL ELECTRICAL,AND FIRE PROTECTION EMAIL:DGOGARTY@DILLJAMES.COM <br /> 3.WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED"N.I.C."OR SPECIFICALLY ASSIGNED TO DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS.THE CONTRACTOR SHALL NOTIFY THE TYPE OF CONSTRUCTION: II-B <br /> ANOTHER PARTY. ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS'DRAWINGS WITH A WRITTEN <br /> REQUEST FOR CLARIFICATION.ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR CONTRACTOR MORIS CONSTRUCTION SPRINKLERED: YES <br /> 4.CONTRACTOR SHALL VISIT THE SITE,REVIEW THE DRAWINGS AND SUBMITTED BY THE ARCHITECT, SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING 3112 177TH PL SW are you <br /> AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR OWNER,TENANT,OR ARCHITECT. LYNWOOD,WA 98037 OCCUPANCY CLASSIFICATION: M(MERCANTILE) <br /> CONSTRUCTION. CONTACT:SCOTT MORIS <br /> 5.ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND CABLE TRAYS SHALL HAVE A PHONE:206.602.9734 NUMBER OF STORIES: 1 <br /> 5.ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. EMAIL:MORISCONSTRUCTIONLLC@GMAIL.COM <br /> RECOMMENDATIONS OR WRITTEN INSTRUCTIONS. SO FT OF IMPROVEMENT: 1,170 SF <br /> 6.WHERE 6.ALL EXPOSED MATERIALAND PIPING IN RETURN AIR PLENUM MUST MEET FS 25. 77055 Evergreen Way <br /> DETAILS SHALL BETHE I SAME AS ON I FOR OTHER SIMILAR WORKLS ARE NOT SHOWN OR . 7. <br /> FOR ANY PART OF THE WORK,THE 7 ALL PLUMBING,HVAC PIPE,AND DUCTWORK IN PLENUM SHALL HAVE A FLAME SPREAD RATING OF Ste G-07 <br /> LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. <br /> 7.WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR,IT IS INTENDED SHEET INDEX Everett, WA 98203 <br /> THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES,ITEMS OR PARTS AS ARE REQUIRED TO A0.01 General Notes SCOPE OF WORK <br /> PROPERLY COMPLETE THE WORK. SUBMITTALS AND WARRANTY <br /> A1.00 Code Plan TENANT IMPROVEMENT WORK FOR A PRINT SHOP TO INCLUDE DEMOLITION OF NON-LOAD BEARING <br /> 8.DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWINGS SHALL BE 1.SUBMIT A LIST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO THE OWNER FOR A3.00 Demolition Plan and Floor Plan PARITION WALLS AND CONSTRUCTION OF(1)NON-LOAD BEARING PARTITION WALL.THE EXISTING <br /> CALLED TO THE ATTENTION OF THE ARCHITECT. APPROVAL PRIOR TO START OF CONSTRUCTION. RESTROOM IS TO REMAIN AS-IS.NO EXTERIOR WORK OR SITE WORK IS PROPOSED UNDER THIS <br /> PERMIT. <br /> 9.VERIFY ALL"BUILDING STANDARDS"WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. 2.ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS(WITH EXCEPTION TO SPECIFIC FINISH <br /> HOWEVER,THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS COLORS AND FLOORING)ARE INTENDED TO BE ON AN"OR EQUAL"BASIS.ANY PROPOSED DEFERRED SUBMITTALS <br /> WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF.THE CONTRACTOR AGREES TO DEFEND, SUBSTITUTIONS MUST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY <br /> INDEMNIFY,AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF OF SCHEDULE. THE FOLLOWING PORTIONS OF THE PROJECT WILL BE APPLIED FOR UNDER SEPARATE PERMITS: <br /> UNAPPROVED CHANGES. <br /> 3.ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER COMPLETION,UNLESS 1.LIFE SAFETY SYSTEM MODIFICATIONS,IF REQUIRED(HORN,STROBES&FIRE ALARM/SPRINKLER <br /> 10.ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. OTHERWISE SPECIFIED,AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND MODIFICATIONS) <br /> AGREEMENT.ALL REPAIRS,CORRECTIONS,DISCREPANCIES,ETC.,MUST BE MADE WITHOUT ANY 2.LOW VOLTAGE ELECTRICAL SYSTEMS.(TELEPHONE,DATA,SECURITY,INTERCOM) <br /> 11.VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW ADDITIONAL COST TO THE OWNER,AND WITHIN FIVE(5)DAYS AFTER NOTICE IS GIVEN. 3.TENANT SIGNAGE <br /> MANUFACTURERS. 4.MECHANICAL,PLUMBING,AND ELECTRICAL <br /> 12.CONSTRUCT WALLS PLUMB AND SQUARE WITH NEW CONSTRUCTION UNLESS NOTED OTHERWISE. FIRE PROTECTION <br /> 13.LATHING,PLASTER,AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE 1.IF NECESSARY,PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RATED ELEMENTS AS APPLICABLE CODES <br /> 2021 IBC REQUIRED BY CODE. EVERETT MUNICIPAL CODE <br /> 2021 INTERNATIONAL BUILDING CODE-CHAPTER 51-50 WAC <br /> 14.ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 2021 IBC AND THE U.S. 2.FIRE EXTINGUISHERS:VERIFY LOCATION,TYPE,AND SIZE PER FIRE MARSHAL REQUIREMENTS. 2021 INTERNATIONAL EXISTING BUILDING CODE <br /> PRODUCT SAFETY COMMISSION:SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS(42 CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER 2021 INTERNATIONAL MECHANICAL CODE-CHAPTER 51-52 WAC <br /> FIR 1426:16 CFR PART 1201). NFPA 10 MOST RECENT EDITION AND APPROVED BY THE FIRE MARSHAL.CONFIRM ACCEPTABILITY OF 2021 INTERNATIONAL FIRE CODE-CHAPTER 51-54A WAC <br /> LOCATION WITH FIRE MARSHAL PRIOR TO INSTALLATION.PROVIDE FINISHED CABINETS TO MATCH 2O21 UNIFORM PLUMBING CODE-CHAPTER 51-54A WAC <br /> 15.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 2020 NATIONAL ELECTRICAL CODE-CHAPTER 196-46B WAC <br /> WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 2000 INTERNATIONAL ENERGY CONSERVATION CODE AS ADOPTED BY RCW 19.27.031 WITH LOCAL CODE <br /> 3.FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED SO THAT THE TOP OF THE EXTINGUISHER AMENDMENTS <br /> 16.LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM OR CABINET IS NO HIGHER THAN 48"AFF AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE IS 2017 ICC At 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br /> DAMAGE.THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR AT LEAST 36"AFF. <br /> OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. <br /> 4.AT SEMI-RECESSED FIRE EXTINGUISHER CABINETS,WRAP ADDITIONAL LAYER(S)OF TYPE <br /> 17.VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. <br /> NOTED IN THE PLANS OR SPECIFICATIONS. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. <br /> 18.ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN 5.PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE(5"xW)ABOVE EACH FIRE EXTINGUISHER OR <br /> (BROOM)CONDITION AT ALL TIMES. CABINET WITHIN SCOPE OF WORK.MOUNT AT 84"AFF UNLESS OTHERWISE REQUIRED. <br /> 19.MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE,ODOR,FUMES,OR VIBRATION.AT 6.EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 2021 IBC AND THE CITY OF[INSERT <br /> THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY CITY]FIRE MARSHAL REQUIREMENTS.CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING <br /> CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. AND EXIT LIGHTING AS REQUIRED BY THE[INSERT CITY]FIRE AND BUILDING DEPARTMENTS.CONFIRM <br /> ACCEPTABILITY OF LOCATIONS WITH THE BUILDING OWNER BEFORE INSTALLATION.CONTRACTOR <br /> 20.PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IBC ARTICLE. <br /> 21.MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. 7.CONTRACTOR SHALL PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BY ADA <br /> GUIDELINES.CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE <br /> 22.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE DETECTION AS REQUIRED UNDER ARTICLE 9 OF THE IBC.THE INSTALLATION OF THE ABOVE NOTED <br /> WITH ALL APPLICABLE SAFETY CODES. SYSTEM SHALL INCLUDE THE CONNECTION TO AND/OR MODIFICATION OF THE EXISTING BUILDING <br /> SYSTEMS,AS NECESSARY. <br /> 23.THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER <br /> HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE 8.FLAMMABLE LIQUIDS SHALL NOT BE PLACED,STORED,OR DISPENSED IN THIS OCCUPANCY EXCEPT <br /> NEGLIGENCE OF THE CONTRACTOR,HIS AGENTS,EMPLOYEES,OR SUBCONTRACTORS. AS PROVIDED IN NFPA STANDARD 30 AND THE 2021 INTERNATIONAL FIRE CODE.PERMIT MAY BE <br /> REQUIRED. <br /> 24.APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS.ALL <br /> CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, 9.ALL DRAPES,HANGINGS,CURTAINS,AND ALL OTHER DECORATIVE MATERIALS,INCLUDING <br /> ADDENDA,AND CHANGE ORDERS.THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION,ONE CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE <br /> COMPLETE SET OF PLANS WITH ALL REVISIONS,ADDENDA,AND CHANGE ORDERS,ON THE PREMISES FROM NONFLAMMABLE MATERIAL,OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT <br /> AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE <br /> MARSHAL.PROVIDE A CERTIFICATION TO THIS EFFECT.DECORATIVE MATERIAL SHALL NOT CONCEAL <br /> 25.PROVIDE COMPLETE SECURITY OF PREMISES WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS OR OBSTRUCT ANY EXIT DOORS,EXIT LIGHTS,AND FIRE EXTINGUISHER LOCATIONS.MINIMUM FLAME <br /> COMPLETE. SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE 803.9,SECTION 803.1 OF THE <br /> 2021 IBC. <br /> 26.AT COMPLETION OF THE WORK,REMOVE ALL DEBRIS FROM THE SITE,LEAVING SPACE CLEAN, <br /> WASH ALL WINDOWS AND GLASS,POLISH ALL HARDWARE AND FIXTURES,REPLACE AND PATCH AREAS 10.ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE <br /> OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT.AT THE END OF SPECIFIC RATING. <br /> CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY CONSTRUCTION <br /> ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. <br /> CEILING VICINITY MAP N <br /> CONSTRUCTION 1.REFLECTED CEILING PLAN IS FOR THE GENERAL INFORMATION OF THE CONTRACTOR.EXACT 20110613 c F F <br /> LOCATIONS SHALL BE VERIFIED. AREA OF WORK REGISTERED <br /> ARCHITECT <br /> 1.INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL,PLUMBING,MECHANICAL,AND <br /> ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY AND <br /> ALL DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. DOOR p -� <br /> p =..,e,�K ILL .,ART! <br /> 2.COORDINATE CONSTRUCTION SCHEDULING WITH THE BUILDING OWNER TO ALLOW ONGOING 1.ALL DOOR HARDWARE TO MEET REQUIREMENTS OF 2021 IBC AND OWNER'S BUILDING STATE OF V HINGTOY <br /> OPERATION OF THE FACILITY DURING CONSTRUCTION. REQUIREMENTS. ¢ale P <br /> 3.PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 2.COORDINATE ALL KEYING REQUIREMENTS WITH OWNER/TENANT.CONTRACTOR SHALL PROVIDE ALL <br /> LOCKSET CYLINDERS TO MATCH OWNER STANDARD.CONTRACTOR SHALL RE-KEY ALL DOORS TO <br /> 4.OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. MEET TENANT AND OWNER'S REQUIREMENTS. <br /> 5.PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. <br /> FINISH AND MATERIALS <br /> 6.PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW <br /> CONSTRUCTION TO RECEIVE NEW SCHEDULED FINISHES.ALL SURFACES ARE TO HAVE"LIKE-NEW" 1.SUBMIT FINISH SAMPLES TO OWNER AND DESIGNER FOR APPROVAL PRIOR TO ORDERING 3P <br /> APPEARANCE. MATERIALS. 2 p p <br /> 4; CAMPUS ISSUE LIST <br /> 7.STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHALL BE IN COMPLIANCE 2.INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR PERMIT SET 09.06.2024 <br /> WITH ASTM C 754 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING REQUIREMENTS. WHEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. j q y <br /> 8.ALL DEMOLISHED MATERIALS TO BE RECYCLED TO AN APPROVED RECYCLER. 3.PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING <br /> MATERIALS INTERSECT. <br /> DIMENSIONS ■r..,m <br /> 1.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE <br /> BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY.THE CONTRACTOR SHALL <br /> VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY I&L a - <br /> DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH <br /> THE WORK. <br /> 2.DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED GWB FACE OF <br /> PARTITIONS,UNLESS NOTED OTHERWISE.DOOR AND CASED OPENINGS WITHOUT LOCATION <br /> DIMENSIONS ARE TO BE FOUR(4)INCHES FROM THE FACE OF THE ADJACENT PARTITION OR <br /> CENTERED BETWEEN PARTITIONS. t p General Notes <br /> 3.DO NOT SCALE DRAWINGS.THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS <br /> AND ACTUAL FIELD MEASUREMENTS.NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. <br /> 9..� : FK y A0.01 <br /> BOEING FREEWAY(WA 526).,M.. <br /> 1011412024 2:42:44 PM <br />