Laserfiche WebLink
GENERAL NOTES <br /> ww <br /> 1. ALL GENERAL NOTES GIVEN HEREIN APPLY TO ALLALLIED TRADES FOR THE PROJECT AMENDED <br /> ELSEWHERE TO INCLUDE ISOLATED CONDITIONS v 0 w <br /> 2. THE DRAWINGS ARE INTENDED G SHOW THE THEY <br /> ENOTIARRANGEMENT,DESIGN AND EXTENT OF P J P Everett Mall Office Park ` m; <br /> THE WORK DRAWINGS <br /> ARE PARTLY DIAGRAMMATIC THEY ARE NOT INTENDED D SI SCALED. z <br /> 3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL x m <br /> BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. Commercial T.I. Building III Suite 1 10 <br /> 4. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY ALL GRADES,LINES,LEVELS, <br /> CONDITIONS,AND DIMENSIONS AT THE JOB SITE AND AS SHOWN ON THE DRAWINGS.THEY SHALL <br /> REPORT ANY ERRORS OR INCONSISTENCIES IN THE ABOVE TO THE ARCHITECT BEFORE <br /> COMMENCING WORK. <br /> 5. CONTRACTOR AND SUBCONTRACTORS SHALL OUT THEIR WORK FROM ESTABLISHED REFERENCE 906 SE Everett Mall Way Everett, WA 98208 <br /> POINTS AND BE RESPONSIBLE FOR ALL LIINES,ELEVATIONS AND MEASUREMENTS IN CONNECTION <br /> WITH THEIR OWN. <br /> 6. PROTECTION: 00 <br /> O <br /> A. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE REQUIREMENTS OF THE y-- N <br /> BUILDING CODE HAVING JURISDICTION AND ALL LOCAL,STATE,AND FEDERAL LAWS. (� 00 <br /> 00 <br /> B. PROVIDE ALL SHORING AND BRACING AS REQUIRED FOR THE PROPER EXECUTION OF THE <br /> WORK.REMOVE WHEN WORK IS COMPLETED. <br /> C. PROVIDE AND MAINTAIN GUARD LIGHTS AND BARRICADES AT ALLAREAS OF WORK > <br /> ADJACENT TO PUBLIC WAYS OR PUBLIC SPACES. <br /> D. AT ALL TIMES PROVIDE PROTECTION AGAINST WEATHER(RAIN,WIND,STORMS,OR HEAT)SO U N <br /> AS TO MAINTAIN ALL WORK,MATERIALS,APPARATUS AND FIXTURES FREE FROM DAMAGE. <br /> E. THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ADJACENT STRUCTURES,SIDEWALKS <br /> AND TO STREETS OR OTHER PUBLIC PROPERTY OR TO ANY PUBLIC UTILITIES. ENERGY NOTES BUILDING NOTES PROJECT NOTES <br /> 7. CONTRACTOR AGREES THAT HE WILL HOLD THE OWN ER,ARCH ITECT AND/OR ANY OF THEIR O <br /> EMPLOYEES OR AGENTS HARMLESS FROM ANY AND ALL DAMAGE CLAIMS WHICH MAY ARISE BY COMMERCIAL COMMERCIAL LLI <br /> ENERGYCODE: 2018 WSEC NUMBER OF STORIES: 6STORIES PROJECT NAME: PJP EVERETT MALL OFFICE PARK _ <br /> REASON UBCO NEGLIGENCEAT PART OFTHE EQUIPMENT SUPPLIERS <br /> OFHISSUBCONTRACTORS 2021 WSEC CONIMERCIALTI. SUITE 110 • <br /> ANDIOR SUBCONTRACTOR'S MATERIALS AND EQUIPMENT SUPPLIERS AND/OR OF THEIR CLIMATE ZONE: HEIGHT: 65'ALLOWED CHANGES PROPOSED) <br /> EMPLOYEES OR AGENTS,IN PERFORMANCE OF THIS CONTRACT;AND IN CASE ANY ACTION IS <br /> BROUGHT BEFORE THEREOF AGAINST THE OWNER,ARCHITECTAND/OR ANY OF THEIR EMPLOYEES PROJECTADDRESS: 906 BE EVERETT MALL WAY,BUILDING III C m <br /> ORAGENTS,CONTRACTOR SHALLASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF,AND COMPLIANCE PATH: PRESCRIPTIVE.FULLY CONDITIONED COMMERCIALADDITION(S).MINIMUM GROSS SF: 114,600 GSF(NO CHANGES PROPOSED) EVERETT,WA 98208 L <br /> UPON HIS FAILURE TO DO SO ON PROPER NOTICE,OWNER,ARCHITECT AND/OR ANY OF THEIR INSULATION REQUIREMENTS PER R-VALUE METHOD TYPE OF CONSTRUCTION: F.R.II- (PER IBC CHAPTER 302) PROJECT DESCRIPTION: INTERIOR OFFICE TENANT IMPROVEMENT ON THE 1ST FLOOR.SCOPE TO +•+ <br /> EMPLOYEES OR AGENTS RESERVE THE RIGHT TO DEFEND SUCH ACTION AND CHARGE ALL COSTS NCLUDE SELECTIVE DEMOLITION OF EXISTING WALLS AND CEILING TILES <br /> THEREOF TO CONTRACTOR. ALTERATIONS: PROJECT SCOPE LIMITED TO INTERIOR REMODEL ONLY.ALL EXISTING EXPOSED SPRINKLERS: NONSPRINKLERED AND CONSTRUCTION OF NEW WALLS TO CREATE NEW OFFICES, <br /> B. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS,SPECIFICATIONS OR OTHER FRAMING CAVITIES SHALL BE FILLED TO FULL DEPTH WITH INSULATION HAVING CONFERENCE ROOM,LOBBY,AND BREAK ROOM IN SUITE 110.NO EXTERIOR L < <br /> DOCUMENTS,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF SUCH OMISSIONS MIN.NOM.VALUE OF R-3.0 PER INCH. OCCUPANCYTYPE: B-BUSINESS(FIRST FLOOR ONLY) WORK INCLUDED.NO CHANGE IN OCCUPANCY. (3) TO <br /> OR ERRORS PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION.IN THE PER IBC CHAPTER 3(SECTION 302) L OJ <br /> EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH NOTICE,HE SHALL BE HELD RESPONSIBLE BUILDING ENVELOPE: NO NEW CONDITIONED AREA OR CHANGE TO CONDITIONED ENVELOPE (EXISTING NO CHANGE) OWNER: PIETROMONACO JACKSON PROPERTIES <br /> ' FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE PROPOSED. 7525BE24THST,SUITE300 LJJ Q) CID <br /> SAME.THE CONTRACTOR SHALL HAVE ALL ITEMS OR DETAILS CLARIFIED WITH THE ARCHITECT BLDG AREA SUMMARY: EXIST. MERCER ISLAND,WA 98040 I <br /> PRIOR TO SUBMITTING A BID;OTHERWISE THE ARCHITECTS INTERPRETATION SHALL BE FINAL. AIR LEAKAGE: TESTING NOT REQUIRED FORALTERATIONS WITH NO NEW CONDITIONED SPACE. FIRST FLOOR: T3420-SF 1(206)607-6021 <br /> SECOND FLOOR: 19,600 SF LLJ <br /> 9. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS TOGETHER WITH THE THIRD FLOOR: 20,314 SF CONTACT:DANNY JACKSON DANNY@PJPNW.COM a- Ln <br /> ARCHITECTURAL,MECHANICALAND ELECTRICAL DRAWINGS TO LOCATE DEPRESSED SLABS, MECHANICAL(DEFERRED): EXISTING MECHANICAL SYSTEM SHALL BE ALTERED TO SERVE NEW SPACES. FOURTH FLOOR: 20,442 SF O <br /> SLOPES,DRAINS,OUTLETS,RECESSES,OPENINGS,REGLETS,BOLT SETTING,SLEEVES, ALTERATIONS SHALL NOT CAUSE EXISTING SYSTEM TO BECOME OUT OF FIFTH FLOOR: 20,442 SF ARCHITECT: BRODERICK ARCHITECTS U p <br /> DIMENSIONS,ETC.POTENTIAL CONFLICTS SHALL BE TRANSMITTED TO THE ARCHITECT BEFORE COMPLIANCE WITH CURRENT CODE. SIXTH FLOOR: 20,442 SF 55 S.ATLANTIC STREET,SUITE 301 Q� <br /> PROCEEDING WITH THE WORK. <br /> SEAT7LE,WA 98134 <br /> 10. ALL WOOD WALL DIMENSIONS GIVEN ARE TO EXTERIOR FACE OF FRAMING.LIGHT GA STEEL WALLS ELECTRICAL(DEFERRED): AT LEAST 50 ICES,O 125 VOLT 15-AMP&CONFERENCE <br /> RECEPTACLES INSTALLED IN TOTAL BUILDING 114,600 SF(NO CHANGE) 206.682.7525 <br /> ARE DIMENSIONED TO CL OF FRAMING. PRIVATE OFFICES,OPEN OFFICES,CONFERENCE ROOMS,ROOMS USED PRIMARILY 206.682.7529(F) <br /> FOR PRINTING AND/OR COPYING FUNCTIONS,BREAK ROOMS,INDIVIDUAL <br /> S 11. SOME CONNECTIONS INDICATED ON THE DRAWINGS ARE SCHEMATIC.SECURE ALL COMPONENTS WORKSTATIONS,AND CLASSROOMS,INCLUDING THOSE INSTALLED IN MODULAR AREA OF WORK: 2,290 SF TOTAL(SUITE 110,FIRST FLOOR ONLY) CONTACT:KIELEANN SCHEELER KIELEANN@BRODERICKARCHITECTS.COM <br /> RIGIDLYTO STRUCTUREAND EACH OTHER.USE FASTENERS DESIGNED FOR EACH INSERVICE PARTITIONS AND MODULAR OFFICE WORKSTATION SYSTEMS,SHALL BE <br /> CONNECTION. CONTROLLED RECEPTACLES EITHER,SPLIT RECEPTACLES WI TOP RECEPTACLES TENANT IMPROVEMENT EXIST. NEW PROPOSED STRUCTURAL ENGINEER: CRW ENGINEERING GROUP,LLC <br /> CONTROLLED OR:CONTROLLED RECEPTACLE LOCATED WII 12"OF EACH SUMMARY: SUITE 110: 2,290 SF 0 SF OSF 3940 ARCTIC BLVD <br /> 12, OBTAIN CLARIFICATION AND INTERPRETATION OF DRAWINGS AND SPECIFICATIONS,INCLUDE UNCONTROLLED RECEPTACLE,CONTROLLED RECEPTACLES SHALL BE VISIBLY REMAINING: 11,130 SF 0 SF OSF SUITE 300 <br /> ADDITIONAL DETAIL,DIRECTLY FROM ARCHITECT. DIFFERENTIATED WI STANDARD SEATTLE ELECTRICAL CODE SYMBOL. ANCHORAGE,AK 99503 <br /> Y APPLICABLE CODES: 2021 IBC WI WASHINGTON STATE AMENDMENTS 907.562.3252 <br /> 13, WASTE MATERIAL AND RUBBISH FROM DEMOLITION AND ALTERATION OPERATIONS SHALL BE RECEPTACLES SHALL BE CONTROLLED WIOCCUPANT SENSORS OR TIME 2021 IBC WI WASHINGTON STATE AMENDMENTS r4 <br /> CONTROLS. <br /> 2 21 WASHINGTON TATE MMER COMMERCIAL ENERGY DE CONTACT JESSE GOBELI obeli amen.can 1� <br /> REMOVED FROM SITE AS RAPIDLY AS POSSIBLE AND SHALL NOT BE ALLOWED TO ACCUMULATE ON 2oq 0S CO C G CO Ig @ g <br /> PREMISES.DISPOSAL OF MATERIALS WILL BEAT THE DISCRETION OF THE CONTRACTOR.OPEN DANIEL KING dKmg@c­g.com 16 � / iy <br /> s FIRES WILL NOT BE PERMITTED FOR DISPOSAL OF WASTE.CONTRACTOR SHALL PROVIDE AN LIGHTING FIXTURES: A.ALTERATIONS THATADD OR REPLACEM0R MORE LUMINAIRED IN vcc <br /> EXTERIOR AREA TOCOLLECTALL DEMOLISHED NOT TO BE REUSED.THIS AREA SHALL BE SAFE ENCLOSED BY WALLS OR CEILING-HEIGHT PARTITIONS SHALL COMPLY WITH C405.4 CIVIL ENGINEER. LDP ENGINEERING PLLC W <br /> W AND UN-OBSTRUCTING THE BUILDING FUNCTION AND THE OWNER'S DAILY BUSINESS OPERATIONS. &C405.5. 911 WESTERN AVE,SUITE 420 �p <br /> o SEATTLE,WA 98109 p <br /> & 14. EXISTING UTILITY LINES INDICATED OR NOTED ON THE DRAWINGS ARE SHOWN AS OBTAINED FROM B.WHERE NEW WIRING IS BEING INSTALLED TO SERVEADDED FIXTURES ANDIOR 206.725.1211 c�1 <br /> U EXSTNG INFORMATION AND ARE PROBABLY INCOMPLETEAND ONLYAPPROXIMATE IN LOCATION. FIXTURES ARE BEING RELOCATED TO A NEW CIRCUIT,CONTROLS SHALL COMPLY <br /> a THE CONTRACTOR SHALL TAKE EXTREME CAUTION TO AVOID DAMAGE TO EXISTING UTILITY LINES WITH C405.2.1,C405.2.3,C405.2A,C405.2.5,&C405.2.6,AND AS APPLICABLE C408.3. CONTACT LAURIE J.PFARR lauriep@idpenglneering com D <br /> >< AND/OR HARM TO PERSONNEL ENGAGED IN WORKING IN THEAREA. NEW LIGHTING CONTROL DEVICES SHALL COMPLY WITH THE REQUIREMENTS OF o <br /> = r l <br /> 0 15, GLAZING TO BE INSULATED GLASS LABELED WITH NFRC CERTIFIED U-VALUE,AND MEETING THE SECTION C405.2 PARCEL NUMBER: 28051800305401 <br /> REQUIREMENTS OF THE ENERGY CODE. p <br /> C.OCCUPANCY SENSORS REQUIRED.SEE NOTES ON SHEETA2.2. LEGAL DESCRIPTION: SECTION 18 TOWNSHIP 28 RANGE 05 QUARTER SW LOT C OF EVERETT MALL - M <br /> OFFICE PARK4 BSP REC BOOK 1 OF BSP PG 258-259 AF 9205295004&BEING m •* <br /> ABBREVIATIONS D.COMMISSIONING NOT REQUIRED PER C408.4 EXCEPTION 1 TOTAL INSTALLED PTN SE114 SIA&AMEND PERAF 9206235004 r M <br /> LIGHTING LOAD IS<2OKW. S \\\ <br /> S00 <br /> � @ AT FOC FACE OF CONCRETE PT PRESSURE TREATED � N <br /> 8 AND FOF FACE OF FINISH PTO PAINTED Z <br /> DEGREE FOS FACE OF STUD °! <br /> e m DIAMETER FTG FOOTING R RETR OR NAIR US PLANNING NOTES DEFERRED SUBMITTALS SHEET INDEX � o <br /> 3 p POUNDS FT FOOT OR FEET RA RETURN AIR <br /> S FERN FURNITURE RAD RADIUS AO.1 TITLE SHEET r< � Z <br /> AS ANCHOR BOLT RCP REFLECTED CEILING V--� <br /> g GA GAUGE OR GAGE PLAN JURISDICTION: CITY OF EVERETT I SNOHOMISH COUNTY AO.2 EXISTING FLOOR PLAN <br /> ABV ABOVE 1. MECHANICAL Q V Q <br /> s ACT ACOUSTICALTILE GALV GALVANIZED REINF REINFORCING ZONING: C-1 GENERAL COMMERCIAL 2. ELECTRICAL AO.3 EXITING PLAN <br /> A/E ARCHITECT/ENGINEER GL GLASS 3. PLUMBING A1.1 DEMOLITION FLOOR PLAN Pz <br /> AFF ABOVE FINISH FLOOR GLB GLUE LAMINATED BEAM READ REQUIRED m Q > <br /> e ALUM ALUMINUM GLZ GLAZING RM ROOM LOTAREA: 71,438 SF(1.64 ACRES) A1.2 PROPOSED FLOOR PLAN <br /> w ALT ALTERNATE GYP GYPSUM RO ROUGH OPENING A2.2 NEW REFLECTED CEILING PLAN . Q HEIGHT: EXISTING(NO CHANGE) ♦♦��,� <br /> s ANSI AMERICAN NATIONAL GW�B GYPSUM WALL BOARD A3.1 ASSEMBLIES AND SCHEDULES I�[�STANDARD H- <br /> INSTITUTE S SOUTH PARKING: EXISTING(NO CHANGE) A3.2 ENLARGED PLANS AND ELEVATIONS E N w <br /> ARCH ARCHITECT OR HB HOSE BIB SA SUPPLYAIR <br /> ARCHITECTURAL HC HOLLOW CORE SC SOLID CORE <br /> A5.1 PROPOSED POWER AND DATA PLAN Ln cn <br /> HD HARDWOOD SCHED SCHEDULE <br /> BD BOARD HDR HEADER SD STORM DRAIN _ • •_ • • d <br /> w BLK'G BLOCKING HDW HARDWARE SECT SECTION Y l� <br /> BLDG BUILDING HF HEM-FIR SF SQUARE FEET �� <br /> BM BEAM HGT HEIGHT SIM SIMILAR <br /> ' BTU BRITISH THERMAL UNIT HIM HOLLOW METAL SPEC SPECIFIED OR M <br /> S BUR BUILT UP ROOF FIR HOUR SPECIFICATION • 4 • 4 • # r.��� <br /> HW HOT WATER SST STAINLESS STEELCIS CATCH BASIN SOUND <br /> CJ CONSTRUCTION JOINT IBC INTERNATIONAL STC COEFFICIENTSMISSION �rM LA_-�- .. <br /> g CL CENTER LINE BUILDING CODE STD STANDARD r�IVNC{i 1 �J�/� •_ <br /> CLG CEILING ID INSIDE DIAMETER STL STEEL <br /> CLR CLEAR ID <br /> INTERNATIONAL FIRE STOR STORAGE • •• <br /> MU CONCRETE MASONRY CODE STRUCT STRUCTURAL <br /> g 11 I I I I I I I � I I I I • 1�� o W <br /> UNIT IN INCHES SUSP SUSPENDED .��•�4 • �• IL�4 <br /> CO CLEAN OUT INSUL INSULATION SYS SYSTEM /•�� a <br /> COL COLUMN INT INTERIOR -� �W - _ �� I <br /> CONE CONFERENCE IPC INTERNATIONAL T TREAD OR TEMPERED 1 _ <br /> GONG CONCRETE PLUMBING CODE T&G TOUNGUEAND O /� M. <br /> a <br /> CONT CONTINUOUS IRC INTERNATIONAL GROOVE / I <br /> COORD COORDINATE RESIDENTIAL CODE TB TOWELBAR <br /> CPT CARPET TB D TO BE DETERMINED • _ o .� <br /> CT GERAMICTILE LAM LAMINATE TOW TOP OF WALL <br /> CV/ COLD WATER LAV LAVATORY TEMP TEMPERED -w S • - • <br /> LB POUNDS THK THICK OR THICKNESS - <br /> d PENNY LF LINEAR FEET THRU THROUGH <br /> DBL DENNY LT LIGHT TORD TOPOGRAPHIC MAP 4, • =- <br /> DEG DEGREE LWC LIGHT WEIGHT TPD TOILET PAPER _ - EXISTING BUILDING <br /> DISPENSER 906 BE EVERETTVAE[WAPEVERET,WA 98208 -s- <br /> DEMO DEMOLISH OR CONCRETE .. <br /> TYP TYPICAL _ BUILDING III <br /> DEMOLITION MATL MATERIAL <br /> OF DOUGLAS FIR MAX MAXIMUM ~ '' • 1 ' • • <br /> DIAM DIAMETER UNO UNLESS NOTED � PARCEL#28051800305401 <br /> MECH MECHANICAL OTHERWISE <br /> DAL DIAGOAL ♦ <br /> DIM DIMENSNION MFR MANUFACTURER UTIL UTILITY M • `-� <br /> ON DOWN MIN MINIMUM •1 1 Y ' 4}. _SITE - - <br /> MIR MIRROR VCT VINYL COMPOSITION <br /> DG DOUBLE GLAZING MISC MISCELLANEOUS TILE <br /> DTL DETAIL VERT VERTICLE t-� now Nag <br /> DS DOWNSPOUT NEC NATIONAL ELECTRICAL VEST VESTIBULE <br /> DW DISH WASHER CODE VTR VENT THROUGH ROOF _ / • I - - -' -i , _ - <br /> (E) ' <br /> EXISTING (N) NEW VTO VENTTOOUTSIDE AREA OF WORK - - �' <br /> EE N NORTH OR NEW ♦ 2,290 SF TOTAL <br /> EAST OR EXISTING NIC NOT IN CONTRACT W WEST <br /> EA EACH • • • SUITE 110,FIRST FLOOR - <br /> EIFS EXTERIOR INSULATION IN NUMBER W/ WITH INTERIOR WORK ONLY -- <br /> FINISH SYSTEM NOM NOMINAL WC WATER CLOSET <br /> ELECT ELECTRICAL NRC NOISE WD WOOD <br /> COEFFCIENT REDUCTION WDW WINDOW <br /> EXT EXTERIOR NTS NOT TO SCALE WE WIDE FLANGE d' 8/21/24 <br /> ELEV ELEVATION WG WIRE GLASS - ' <br /> EQUIP EQUIPMENT ' 3 Y <br /> EQ EQUAL OC ON CENTER WH WATER HEATER <br /> l� • • 1 • • • • �1• . . . • • . . • . •�L l 1 1 l E -1_��, - <br /> EW EACH WAY OPNG OPENING W/O WITHOUT l l l J -� ( TITLE SHEET <br /> EXIST EXISTING WP WATERPROOF <br /> PIE PROPERTY LINE OR WSEC WASHINGTON STATE _V_ TT.•rZ <br /> FD FLOOR DRAIN PLATE <br /> ENERGY CODE <br /> WT WEIGHT <br /> FDN FOUNDATION PLAM PLASTIC LAMINATE WWF WELDED WIRE FABRIC SITE PLAN - EXISTING VICINITY MAP <br /> FEC FIRE EXTINGUISHER PLYWD PLYWOOD WWM WELDED WIRE MESH AO I <br /> CABINET PNL PANEL 1" =40' o 20' 90' BP N.T.S. <br /> FF FINISH FLOOR PROP PROPERTY YD YARD <br />