My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
AINSWORTH INC
>
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 2:36:00 PM
Creation date
3/24/2025 9:52:13 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
AINSWORTH INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESSIBLE ROUTE NOTES EXITING PLAN NOTES EXITING PLAN LEGEND ww CV' <br /> o <br /> 1. INTERIOR FLOOR SURFACE AND EXTERIORACCESSIBLE ROUTE SHALL BE 1. CONSTRUCTION TYPE:II-FR 11.ATACTILE SIGN STATING EXIT IN RAISED CHARACTERS AND ### a m 3 <br /> STABLE,FIRM AND SLIP RESISTANT BRAILLE AND COMPLYING WITH ICC A117.1 SHALL BE $ <br /> 2. SPRINKLERS:NOWSPRINKLERED PROVIDED ADJACENT TO EACH DOOR LEADING TO THE EXIT w� <br /> 2. THRESHOLDS AT DOORS SHALL BE BEVELED AND NOT MORE THAN 112'IN DISCHARGE. INDICATES THE NUMBER OF OCCUPANTS <br /> (IBC 1013.4). x m <br /> HEIGHT 3. EXISTING EMERGENCY VOICEIALARM COMMUNICATION AT EACH EXIT OR EXIT COMPONENT � <br /> SYSTEM TO REMAIN.CONTRACTOR SHALL MODIFY AS 12.THE MEANS OF EGRESS,INCLUDING THE EXIT DISCHARGE, <br /> 3. NO SLOPE SHALL EXCEED 1:48 ALONG THE ACCESSIBLE ROUTE NECESSARY FOR NEW SPACES.MODIFICATIONS NOT SHOWN SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE <br /> ON ARCHITECTURAL DRAWINGS;INCLUDED IN DEFERRED SERVED BY THE MEANS OF EGRESS IS OCCUPIED.THE <br /> 4. MANEUVERING CLEARANCES SHALL BE PROVIDED AT DOORS PERA117.1 SUBMITTAL IF NECESSARY. ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1-FOOT- EXIT SIGN/DIRECTIONAL EXIT SIGN W/ <br /> SECTION 404 CANDLE AT THE WALKING SURFACE LEVEL.(IBC 1008.2 AND EMERGENCY LIGHTING <br /> 4. REQUIRED EXIT DOOR WIDTH:0.15 INCHES PER OCCUPANT 1008.2.1) <br /> (IBC 1005.3.2.1).MINIMUM DOOR WIDTH:32 INCHES.(IBC <br /> 1010.1.1) 13.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO <br /> PROVIDE INITIAL ILLUMINATION THAT IS AT LEASTAN 4--------- COMMON PATH OF TRAVEL 00 <br /> O O 5. MAXIMUM EXITACCESS TRAVEL DISTANCE:131 FT FROM AVERAGEOF1 FOOT-CANDLE AND A MINIMUM AT ANY POINT O <br /> EXECUTIVE OFFICE TO EGRESS DOOR NO.2 EXIT.(200 FT OF 0.1 FOOT CANDLE.(IBC 1008.3.5). y_ O N <br /> ALLOWED PER IBC TABLE 1017.2) � <br /> 00 <br /> 14.IN THE EVENT OF A POWER FAILURE AN EMERGENCY <br /> 6. REQUIRED CORRIDOR WIDTH:.15 INCHES PER OCCUPANT ELECTRICAL SYSTEM SHALLAUTOMATICALLY ILLUMINATE _ 1-HR RATED FIRE BARRIER Q <br /> (IBC 1005.3.2.1) THE FOLLOWING AREAS(IBC 1008.3.1): 3 <br /> MINIMUM/4INCHES CLEAR CORRIDOR WIDTH REQUIRED -AISLES V Cn <br /> (IBC 1020.2) -CORRIDORS +-+ <br /> -EXIT ACCESS STAIRWAYS - N <br /> 7. THRESHOLDS AT DOORWAYS SHALL NOT EXCEEDS'ABOVE -VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE ---- COMMON PATH OF TRAVEL <br /> 130 THE FINISHED FLOOR OR LANDING.(IBC 1010.1.7) USED FOR EXIT DISCHARGE O a)1 -ELECTRICAL EQUIPMENT ROOMS - LLI <br /> -� 8. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE -FIRE PUMP ROOMS � M <br /> EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL -GENERATOR ROOMS (� <br /> KNOWLEDGE OR EFFORT.(IBC 1010.1.9) C m <br /> 9. DOOR HANDLES,PULLS,LATCHES,LOCKS,AND OTHER 15.SEE REFLECTED CEILING PLANS FOR EXIT SIGN LOCATIONS L 3 <br /> � <br /> O / OPERATING DEVICES REQUIRED TO BE ACCESSIBLE BY 16.LENGTH OF DEAD END IN CORRIDOR SHALL NOT EXCEED 50 <br /> O r CHAPTER 11 SHALL BE INSTALLED BETWEEN 34"AND 48" FEET ON THE SECOND FLOOR IS OCCUPANCY).(IBC 1020.4.2) (13 <br /> g ABOVE THE FLOOR SURFACE AND SHALL NOT REQUIRE <br /> S TIGHT GRASPING,PINCHING OR TWISTING OF THE WRIST TO 17.CONTRACTOR SHALL FIELD VERIFY FIRE EXTINGUISHER (3) (C + <br /> 140 OPERATE.(IBC 1010.1.9.1 AND 1010.1.9.2) LOCATIONS,NOT TO EXCEED 150'APARTAND PROVIDE NEW > L 0) <br /> FIRE EXTINGUISHERS AS NECESSARY.CONTRACTOR SHALLcu <br /> 10.EXIT AND EXITACCESS DOORS SHALL BE MARKED BYAN VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. W j <br /> APPROVED EXIT SIGN READILY VISIBLE FROM ANY E W <br /> DIRECTION OF EGRESS TRAVEL.EXIT SIGN PLACEMENT W <br /> v SHALL BE SUCH THAT NO POINT IN AN EXIT ACCESS a- O <br /> CORRIDOR IS MORE THAN 100'OR THE LISTED VIEWIN1.0 <br /> G <br /> O DISTANCE FOR THE SIGN,WHICHEVER IS LESS.(IBC 1013.1); U O <br /> EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY a) <br /> ILLUMINATED. <br /> 3 O <br /> N <br /> V-1 <br /> cc <br /> 120 Lu <br /> 150 N <br /> g O 5 <br /> o O ON o <br /> \ I S Q W M <br /> x m co <br /> o I <br /> H- <br /> s � C7 <br /> s \ I LLj � Z <br /> � ,n <br /> ^\ Z <br /> ELEC o o JAN O Q <br /> O m u) V) <br /> JAN <br /> I <br /> STORAGE ■ <br /> 16 � �� ���k PARKING <br /> -------------- <br /> n \ i <br /> 7 <br /> i UP <br /> I <br /> I <br /> NAM <br /> 8/21/24 <br /> 0 EXITING PLAN <br /> PROPOSED FIRST FLOOR SUITE 110 EXITING PLAN o AO.3 <br /> A0.3 1/8" = V-0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.