My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
AINSWORTH INC
>
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 2:36:00 PM
Creation date
3/24/2025 9:52:13 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
AINSWORTH INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application <br /> EDWARDS iO Series life safety systems are powerful intelligent solu- Flexibility built right in <br /> tions for small to mid-sized buildings.Advanced intelligent technol- Two fully-programmable front panel switch/LED combinations pro- <br /> ogy delivers the benefits of flexible system installation,while clean vide an added measure of flexibility.Their slide-in labels take the <br /> and easy-to-operate user interfaces make panel operation and mystery out of custom applications, and present a clean finished <br /> system maintenance quick and intuitive. appearance. <br /> The smart choice Perfect for retrofits <br /> Signature Series electronic addressing eliminates the tedium of EDWARDS iO Series control panels are particularly well-suited to <br /> setting dipswitches,and automatic device mapping ensures that retrofit applications.All connections are made over standard wiring <br /> each device resides on the system at its correct location. Mean- -no shielded cable required.This means that in most situations <br /> while, innovative programming allows the designer to customize existing wiring can be used to upgrade a legacy control panel to <br /> the system to precisely suit the needs of the building owner. iO technology without the expense or disruption of rewiring the en- <br /> tire building. iO control panels also support the ingenious RZI16-2 <br /> Reliability you can count on Zone Module,which adds up to 16 conventional circuits and two <br /> The inherent fault-tolerant characteristics of Analog/Addressable NACs.This combination easily accommodates new intelligent <br /> Technology boosts the reliability of EDWARDS fire alarm systems. detection alongside existing conventional circuits, making it an <br /> When combined with iO Series smoke and heat detectors,these superior solution in the retrofit market. <br /> systems deliver a level of dependability not previously available for <br /> small to mid-sized applications.All EDWARDS systems are built to Signals with a difference <br /> exacting reliability benchmarks and meet international standards iO system NACs are configurable to fully support the advanced <br /> for quality, in addition to agency listings for dependability. signaling technology of EDWARDS Genesis and Enhanced Integ- <br /> rity notification appliances.These devices offer precision synchro- <br /> Clear-cut remote annunciation nization of strobes to UL 1971 standards. For Genesis devices, <br /> Remote annunciation is a strong suit of the iO Series fire alarm enabling this feature allows horns to be silenced while strobes on <br /> systems. Up to eight annunciators can be installed on a single the same two-wire circuit continue to flash until the panel is reset. <br /> system. Compatible annunciators include a range of LED and LCD <br /> models that provide zone or point annunciation,as well as com- A complete line of accessories <br /> mon control capabilities. iO control panels also supports graphic iO Series life safety systems are supported by a complete line of <br /> annunciation with optional RA Graphic Annunciator interface mod- analog/addressable detectors, modules and related equipment. <br /> ules. Each interface provides common control and 32 LEDs. Consult the Ordering Information section for details. <br /> Programming and remote diagnostics Dimensions <br /> EDWARDS iO Series life safety systems are simple to set up,yet 111 <br /> �02-� 03 f21 (3) (4) <br /> offer advanced programming features that put these small building <br /> panels into a class of their own.The auto programming feature 01 00 6 60 a0 O O <br /> quickly gets the panel operational using factory default settings. I• I O <br /> Basic zone and point settings can be programmed through the O O <br /> front panel interface,so the system is up and running in no time. 1 1 O <br /> O O <br /> For more advanced system configuration and correlation groups D' 1 D4 <br /> programming, iO Series systems interface to a PC running com- 0 <br /> O O <br /> patible iO-CU software.This option offers full system configuration <br /> in the familiar Windows®operating environment. Connection is ° ® o <br /> made to a laptop through the panel's optional RS-232 communi- <br /> cations port,which can also be used to connect a system printer. <br /> Among the many innovative features of iO Series control panels h-D6� 'I <br /> is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached <br /> 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. <br /> to the control panel from any remote location with the correct <br /> communications protocols.The connection can be used to Panel dimensions,in(cm) <br /> download to the panel from the iO-CU, or upload and view system Model 131* D2 D3 D4 1)6* D6 D7 D6 D9 <br /> reports using the iO-CU. 01000 28.0 3.85 9.0 22.0 15.75 10.25 4.4 28.2 2.7 <br /> (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (11.1) (71.6) (6.8) <br /> Available system reports include: i064 21.5 3.85 7.5 15.5 14.25 10.25 4.5 21.7 2.7 <br /> (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (11.4) (55.1) (6.8) <br /> • Correlation groups • Device details *Add 1-112 in.(3.81 cm)to D1 and D5 dimensions for trim kit.The trim kit <br /> • Device maintenance • History provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. <br /> • Internal status • System configuration <br /> • System status • Walk test <br /> • Dialer • CO runtime <br /> Page 2 of 8 DATA SHEET E85001-0135 <br /> Not to be used for installation purposes. Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.