My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
222 W MARINE VIEW DR 2025-04-08
>
Address Records
>
W MARINE VIEW DR
>
222
>
222 W MARINE VIEW DR 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 3:34:17 PM
Creation date
3/24/2025 10:23:11 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
222
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TECHNICAL DATA BULLETIN <br /> VersiWeld TPO Reinforced Membrane <br /> Extreme Testing for Severe Climates Environmental Cycling subjects the membrane to repeated cycles of heat <br /> ASTM Standard D6878 is the material specification for Thermoplastic aging, hot-water immersion and xenon-arc exposure. <br /> Polyolefin-Based Sheet Roofing. It covers material property requirements 0 ASTM requirement-none <br /> for TPO roof sheeting and includes initial and aged properties after heat <br /> and xenon-arc exposure.As stated in the scope of the standard, "the tests Versico EXTREME test*: <br /> and property limits used to characterize the sheet are values intended to - 10 days heat aging at 240OF(116°C)followed by <br /> ensure minimum quality for the intended purpose.'Versico's goal is to - 5 days water immersion at 1580F(70°C)followed by <br /> produce TPO that delivers maximum performance for the intended purpose - 5,040 kJ/m2(2000 hrs at 0.70 W/m2 irradiance)xenon-arc <br /> of roofing membranes. Maximum performance requires the membrane to <br /> exposure <br /> far exceed the requirements of ASTM D6878. <br /> *Test specimen is 2.75"by 5.5"(69.85 mm by 140 mm)piece of membrane with edges <br /> Heat Aging accelerates the oxidation rate that roughly doubles for each sealed. <br /> 180F(10°C) increase in roof membrane temperature. Oxidation (reaction *Criterion-after 3 complete cycles,test specimens shall remain flexible and not have <br /> with oxygen) is one of the primary chemical degradation mechanisms of any cracking under lox magnification while wrapped around a 3"(76.2 mm)-diameter <br /> roofing materials. mandrel. <br /> Supplemental Approvals, Statements and <br /> Versico Extreme Testing - Heat Aging Characteristics: <br /> ASTM Requirement VersiWeld 1. VersiWeld TPO meets or exceeds the requirements of ASTM D6878 <br /> Requirement <br /> Standard Specification for Thermoplastic Polyolefin-Based Sheet <br /> ASTM Test 240'F 32 weeks* >128 weeks Roofing. <br /> *Heat exposure comparable to 3,120 weeks(60 years)at 185°F for 8 hours/day. <br /> 2. Radiative properties for ENERGY STAR, Cool Roof Rating Council <br /> • Test specimen is 2" by 6" (50.8 mm by 152.4 mm)piece of (CRRC)and LEED. <br /> 45-mil(1.14 mm)membrane unbacked, placed in a circulating <br /> hot-air oven. 3. VersiWeld TPO membranes conform to requirements of the US <br /> E.P.A.Toxic Leachate Test(40 CFR part 136) performed by an <br /> • Criterion-no visible cracks after bending aged test specimen independent analytical laboratory. <br /> around 3" (76.2 mm)-diameter mandrel. <br /> 4. VersiWeld TPO was tested for dynamic puncture resistance per <br /> A-Trac testing combines accelerated weathering with real world conditions ASTM D5635-04 using the most recently modified impact head. <br /> using an array of ten mirrors to reflect and concentrate full spectrum 45-mil (1.14 mm)was watertight after an impact energy of 12.5 <br /> sunlight onto membrane test specimens.The Q-Trac device automatically J (9.2 ft-Ibf)and 60-mil (1.52 mm)was watertight after 22.5 J <br /> tracks the sun's path from morning to night.Also, it adjusts to compensate (16.6 ft-Ibf). The 80-mil (2.03 mm)was watertight after an impact <br /> for seasonal changes in the sun's altitude. Eight years in Q-Trac testing is energy of 30.0 J (22.1 ft-Ibf). <br /> equal to 40 years of real-world exposure.Versico requires its VersiWeld <br /> TPO membranes to pass the equivalent of 40 years of exposure in the 5. NSF-P151 Certification for rainwater catchment system components. <br /> Q-Trac. - Plant 91/White Only <br /> Versico Extreme Testing - Q-TRAC <br /> ASTM Test ASTM D6878 Requirement VersiWeld Requirements <br /> N/A N/A Equivalent of 40 years of <br /> exposure <br /> QVJA <br /> VE2sICo <br /> ROOFING SYSTEMS <br /> BUILDING VALUE <br />
The URL can be used to link to this page
Your browser does not support the video tag.