My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1509 CALIFORNIA ST DAWSON PLACE 2025-04-07
>
Address Records
>
CALIFORNIA ST
>
1509
>
DAWSON PLACE
>
1509 CALIFORNIA ST DAWSON PLACE 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 7:35:23 AM
Creation date
3/24/2025 11:01:28 AM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
1509
Tenant Name
DAWSON PLACE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II <br /> BUILDING CODE <br /> 2021 INTERNATIONAL BUILDING CODE 7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL <br /> OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED <br /> FLOOR LOAD OUT. - <br /> DEAD LOAD : 12 psf 4 <br /> LIVE LOAD: 50 psf 8. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO c N <br /> EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT <br /> SESIMIC DESIGN DATA KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE <br /> 1. SEISMIC IMPORTANCE FACTOR: 1.0 ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL <br /> SEISMIC USE GROUP: I BE REPORTED TO THE ENGINEER SO THE PROPER REVISIONS <br /> 2. SPECTRAL RESPONSE ACCELERATION (Ss):123.1% G MAY BE MADE. MODIFICATIONS TO CONSTRUCTION DETAILS <br /> ASSUMED SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY <br /> 3. SITE CLASS: D <br /> (ASSUMED) THE ENGINEER. <br /> 4. SPECTRAL RESPONSE COEFFICIENTS (SDS):82.5%G N <br /> 5. SEISMIC DESIGN CATEGORY: D <br /> 6. BASIC SEISMIC-FORCE-RESISTING SYSTEM: CANTILEVERED STEEL <br /> COLUMN U <br /> 7. SEISMIC RESPONSE COEFFICIENT (Cs): 0.406 o h M <br /> 8. RESPONSE MODIFICATION FACTOR (R): 1.5 SIMPSON ECCQ, U.N.O. Q a o E <br /> 9. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE <br /> PROCEDURE <br /> o 0-) <br /> FRAMING LUMBER Y m <br /> 1. FRAMING LUMBER SHALL BE HEM-FIR N0. 2. GRADES ARE U1 U cV > <br /> TYPICAL UNLESS OTHERWISE NOTED ON PLANS. LUMBER TO BE (D � <br /> GRADE MARKED PER WCLIB SPECIFICATIONS. BEAM PER PLAN -4x6 DF # 1 POST ABOVE cc <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, -POST PER PLAN @ EA END OF SLIDING WALL 0+ z 3 o v p 3 <br /> EXPOSURE 1 SHEATHING CONFORMING TO EITHER COMMERCIAL W/ A34 EA SIDE Q BOTTOM r7 _ <br /> STANDARDS P51-83, APA PRP-108, OR VOLUNTARY PRODUCT POST/BEAM (ONE SIDE) >o- <br /> STANDARD PSE-92. PROVIDE A MINIMUM OF %" EDGE DISTANCE e-BEARING WALL ABOVE 0 LLJ <br /> ON ALL NAILS AND Ys" EXPANSION JOINT BETWEEN ALL PANEL / <br /> EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: . . +, <br /> o I e Cf) <br /> SUB FLOORING TO BE 34" TONGUE AND GROOVE C-D <br /> INT-APA RATED PLYWOOD OR OSB WITH EXTERIOR GLUE, <br /> P.I. 48/24. GLUE AND NAIL WITH 10d NAILS AT 6" ON SIMPSON CCQ, U.N. BEAM PER PLAN <br /> CENTER AT PANEL EDGES AND 12" ON CENTER AT POST PER PLAN ~�` <br /> INTERMEDIATE MEMBERS. -DBL JOIST INTERIOR SUPPORT <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE POST BEAM TWO SIDES} FOR SLIDING WALL POST ABOVE <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. USE <br /> COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. nTYP. POST TO BEAM FLOOR SUPPORT AT <br /> SP CIIFICALLYTDETAILEDURAL MORRAPPROVED SHALL EIN WRIITING CUT OR OBY THE TCHED UNLESS ` CQNN UPPER POST <br /> STRUCTURAL ENGINEER. <br /> 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND NUTS <br /> OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. <br /> 6. PROVIDE 3"x3"x0.229" WASHERS AT ALL ANCHOR BOLTS. <br /> 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS J46" (n 0 <br /> UNLESS NOTED OTHERWISE. LAG BOLT PILOT HOLES SHALL BE <br /> PRE-DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE LAG LJ_I N <br /> BOLT UNLESS NOTED OTHERWISE. <br /> 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH Q Z G <br /> %" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM OF 48" ON _J <br /> CENTER. BOLTS MUST BE EMBEDDED A MINIMUM OF 7' INTO O Q <br /> CONCRETE OR MASONRY. SEE PLANS AND DETAILS FOR SPECIFIC CL <br /> REQUIREMENTS WHERE APPLICABLE. LL_ <br /> 9. RIM JOIST IS TO BE HF#2 MINIMUM. <br /> 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION O < <br /> WALLS AND SOLID BLOCKING UNDER PERPENDICULAR PARTITION W <br /> WALLS. <br /> 11. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO Q m <br /> THESE DETAILS. 0 W <br /> GENERAL W <br /> 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE <br /> CONTRACT DRAWINGS. <br /> 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL COMA <br /> BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE ti5 AS <br /> CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, <br /> AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND <br /> LOCAL SAFETY ORDINANCES. ANY DEVIATION MUST BE y <br /> APPROVED IN WRITING PRIOR TO ERECTION. B 34383 <br /> 9c��rrrEnE° <br /> 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA <br /> STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA <br /> �. <br /> PRIOR TO ERECTION. JUN 1 9 2024 <br /> 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL <br /> CONSTRUCTION PROCEDURES. Drawn By. CCC <br /> Checked By. CCC <br /> 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING Date: 06-19-24 <br /> THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. <br /> ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF <br /> THE ENGINEER AND BE RESOLVED PRIOR TO PROCEEDING WITH SDA JOB NO. <br /> THE WORK. <br /> 6210A <br /> 6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF <br /> CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY <br /> INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, STRUCTURAL <br /> SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO <br /> REVIEW BY THE ENGINEER. NOTES <br /> S- 1 . 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.