298 GA-600-2018 FIRE RESISTANCE AND SOUND CONTROL DESIGN MANUAL <br /> FLOOR-CEILING SYSTEMS, WOOD FRAMED <br /> GA FILE NO. FC 5410 GENERIC 1 HOUR <br /> FIRE - <br /> WOOD JOISTS,GYPSUM WALLBOARD <br /> Fire Design: <br /> One layer 1/2"type X gypsum wallboard or gypsum veneer base applied at right angles to <br /> 2 x 10 wood joists 16"o.c, with 5d nails, 1-5/8"long, 0.099"shank, 1/4" heads, 6"o.c. <br /> Nails placed 3/4"from board edge joints and 1/2" from board end joints. Wood joists <br /> supporting 1" T&G wood subfloor and 1"wood finish floor, or 19/32" plywood finished <br /> floor with long edges T&G and 15132" Interior plywood with exterior glue subfloor <br /> perpendicular to joists with joints staggered. Approx.Ceiling Weight:2 psf(Fire) <br /> Fire Test: UL R1319-66,11-9-64, <br /> C I UL Design L5 <br /> ll UL R3501-45,5- <br /> 5-27-65, <br /> UL Design L522; <br /> UL R2717-38,6-10-65, <br /> UL Design L503; <br /> UL R3543-6,11-10-65, <br /> UL Design L519; <br /> ULC Design M502 <br /> 12.INSULATION IN CEILINGS — In floor-ceiling or roof-ceiling systems, the addition or deletion of <br /> mineral or glass fiber insulation in ceiling joist spaces could possibly reduce the fire-resistance <br /> rating. The addition of up to 16-3/4 inches of 0.5 pcf glass fiber insulation (R-40), either faced or <br /> unfaced batt, or loose-fill to any 1- or 2-hour fire-resistance rated floor-ceiling or roof-ceiling system <br /> having a cavity deep enough to,accept the insulation is permitted, provided that one additional layer <br /> �i <br /> of either 1/2 inch type X or 5/8 inch type X gypsum panels is applied to the ceiling. The additional <br /> layer of gypsum panel shall be applied as described for the face layer of the tested system, except <br /> that the fastener length shall be increased by not less than the thickness of the additional layer of <br /> gypsum panel. <br />