Laserfiche WebLink
, , D ECER71E -\ <br /> MA`., 2 $ 2023 Bulletin 074 January 2023 <br /> ___ <br /> e la R ® CITY ei <br /> Pefflllt OF S�fVICG�EVERETTuick Response FIFR56 SprinSkrleress <br /> K-factor 5.6(80) <br /> MINIMINIMMERIMMI <br /> Features <br /> • Standard coverage quick-response sprinklers 'l�e <br /> • Upright, pendent, horizontal sidewall,and vertical sidewall <br /> 111 <br /> • deflectors <br /> • Low profile,compact design 0 <br /> �' •�°° <br /> Available in a wide variety of finishes <br /> Product Description -- <br /> . Model Fl FR56 Upright <br /> Reliable Model Fl FR56 series sprinklers are quick-response <br /> standard spray automatic fire sprinklers utilizing a sensitive 3.0 <br /> mm glass bulb thermal element. <br /> Pendent and horizontal sidewall sprinklers may be installed t <br /> 0 <br /> exposed or surface mounted using escutcheons such as the ,'6 ..' <br /> Reliable Models B,C,or HB(reference Technical Bulletin 204). <br /> When installed recessed or concealed,the Model F1 FR56 series <br /> sprinklers are specifically listed with and may only be installed <br /> with listed Reliable escutcheons and cover plates. Refer to the Model Fl FR56 Vertical Sidewall Model Fl FR56 <br /> technical information on the following pages for specific listings Horizontal Sidewall <br /> for recessed and concealed installations and refer to Figures 5 <br /> and 6 for dimensional information. <br /> Note:Not all versions of the product are shown. <br /> When fitted with an approved water shield,these sprinklers may <br /> considered intermediate sprinklers for use in racks,below grated <br /> walkways,and other areas where intermediate level sprinklers are <br /> required. Note:This bulletin may contain information on New and Legacy <br /> A provides a summary of the approvals and availability of sprinklers that reflects a dimensional change only.Sprinkler Iden- <br /> Tablespecific Model Fl FR series sprinkler configurations.Additional atipproval n <br /> Number(SIN),application,affected. <br /> performance,and listings/ <br /> approval are not otherwise affected.Sprinklers with New frames <br /> technical information for each sprinkler model is provided on the will include the suffix"N"in the order. <br /> following pages. <br /> F1FR Series Sprinklers Summary Table A <br /> Sprinkler K-Factor gpm/psin2 Max.Working Pressure Sprinkler <br /> Model (Ipm/bar1z) Orientation Listings&Approvals psi(bar) Identification <br /> Number(SIN) <br /> Upright cULus,FM,LPCB,VdS, 175(12) RA1425 <br /> Intermediate Upright EC,WM,UKCA 250(17)(cULus only) <br /> cULus,FM,LPCB,VdS, 175(12) RA1414 <br /> EC,WM,UKCA 250(17)(cULus only) <br /> F1 FR56 5.6(80) Concealed Pendent cULus,VdS,EC,WM, 175(12) RA1414 <br /> UKCA 250(17)(cULus only) <br /> Horizontal Sidewall cULus,FM 175(12) RA1435 <br /> 250(17)(cULus only) <br /> Vertical Sidewall cULus,FM,LPCB, 175(12) RA1485 <br /> UKCA <br /> www.reliablesprinkler.com //v? <br />