Laserfiche WebLink
INSTALLATION STEPS: <br /> WOOD SIDING PER ELEV <br /> 1/2"RAINSCREEN 1. CUT AND FOLD SELF-ADHESIVE FLEXIBLE SILL FLASHING INTO <br /> FRAME OPENING;LEAVE BOTTOM EDGE OF SILL FLASHING UNATTACHED. D E S I G N <br /> APPROVED W.R.B. <br /> 2. CUT AND FOLD SELF-ADHESIVE FLEXIBLE CORNER WALL SHEATHING PER <br /> EXTERIOR SHEATHING FLASHING INTO BOTH BOTTOM CORNERS OF FRAME OPENING STRUC. <br /> FLEXIBLE FLASHING,TYP 3. CUT AND FOLD SELF ADHESIVE FLEXIBLE FLASHING INTO JAMB wEmisRP�iou <br /> FRAME OPENING;LEAVE BOTTOM EDGES OF JAMB FLASHING UNATTACHED 6"WOOD TRIM cacaoess auwserspESW+�ED <br /> 4. CUT AND FOLD SELF ADHESIVE FLEXIBLE FLASHING INTO HEAD SHEATHING EDGES FLUSH TINDODCUN rneDTHEpErs�DD.I.. <br /> W/FRAME OPENING c aowasn—N,ISIHECOPERrvorcacsDESEN, <br /> EXTEND MTL. 1/4° FRY REGLET EXTRUDED GVVB FRAMEOPENING. `` MAY <br /> NOT EE REUSED,IN— ART,wrMcur <br /> FLASHING ALUMINUM TRIM,MATCH THE—ENceeSn+ToFSEcaoescN. <br /> SIDING COLOR CASING 5. SEAL WINDOW FRAME TO OPENING.APPLY CONT.BEAD OF <br /> SEALANT WITHIN 1/2" r A. <br /> m LEAVE BOTTOM EDGE OF <br /> OF EDGE OF OPENING OR APPLY CONT. <br /> GAP FOR SEALANT MTL.HEAD FLASHING J H SEALANT ON BACKSIDE OF WINDOW FLANGES @HEAD,JAMB SILL FLASHING UNATTACHED �- <br /> &SEALANT TYPE d &SILL;THEN INSTALL FRAME TO OPENING. - <br /> 00 <br /> PER SIDING MNSS - "CHECK WINDOW FINS FOR DAMAGE.REPAIR OR REPLACE DAMAGED FINS.— OFFSET WALL SHEATHING A.CUT FLASHING <br /> SPECIFICATIONS A B WINDOW, 3"MIN JOINTS FROM JAMB EDGE,TYP. (2)CUTS <br /> "FASTENERS TO BE STAINLESS STEEL ROOFING <br /> NAILS <br /> B-B HEAD (1 1/2")OR EQUAL.MINIMUM PENETRATION INTO t12"(3"WIDER THAN <br /> 6"WOOD TRIM FRAMING TO BE 1— JAMB FLASH.PAPER) <br /> "GALVANIZED FASTENERS ALLOWED WHEN INSTALLING VINYL WINDOWS" B.FOLD INTO— <br /> CORNER <br /> ELEVATION 6"WOOD TRIM 6. WHEN INSTALLING A WINDOW:NAIL BOTTOM CORNER FIRST. - NOTE:PROPERLY PREPARE <br /> SET WINDOW.STRAIGHT,PLUMB&LEVEL BEFORE FRAMING AND SHEATHING TO <br /> TYP 1/2 X 2 P.T.RAIN FRY REGLET SECURING.PROVIDE CONTINUOUS SUPPORT OR SHIMS - FACILITATE PROPER ADHESION <br /> SCREEN BACKING 0/ "J"TRIM NOTES: UNDER FRAME OF SILL IF REQUIRED BY MFR.FASTEN FOR SELF-ADHESVE FLEXIBLE <br /> DRAIN MAT THROUGH SIDES OF FRAME.DO NOT FASTEN THROUGH HEAD FLASHING(S)AND NAIL-FLANGE <br /> BACKER ROD 1, REFER TO THE TYPICAL"FLASHING&WINDOW UNLESS PERMITTED BY WINDOW MFR. - 1.MEMBRANE SILL FLASHING WINDOW(S). 2.MEMBRANE SILL CORNER FLASHING <br /> &SEALANT INSTALLATION <br /> O THE AIL"FOSEQUE INFORMATION NG 7. INSTALL BUILDING PAPER FROM THE BOTTOM TO TOP OF THE WALL <br /> R.O.DI RELATING SILL BELOW INSTALLATION OF SELF-ADHESIVE FLEXIBLE SHINGLE EACH COARSE TO FACILITATE PROPER DRAINAGE. <br /> FLASHING&BUILDING PAPER. <br /> SEE B-8 FOR 2.SIDING TO BE INSTALLED PER MFR'S <br /> ELASTOMERIC <br /> A-AJAMB TYP NOTES SPECIFICATIONS SEALANT NOTE:IF THE SUPPLIED <br /> NAIL FLANGE CONTAINS <br /> 9"MIN PRE PUNCHED HOLES FOR <br /> PLACE EXTRA NAILING,ALL UNUSED <br /> SEALANT @ MITER HOLES MUST BE FILLED <br /> GAP FOR SEALANT S LAP RT.LEG OF JAMB CORNERS WINDOW <br /> 3p FLASHING MIN.3",TYP. FRAME BACKSIDE) <br /> W/SEALANT. <br /> SIDE) <br /> &SEALANT TYPE <br /> PER SIDING MFR'S <br /> 3"MIN WRAP INTO JAMB INSTALL FASTENERS AT <br /> SPECIFICATIONS <br /> A C CONDITION PER <br /> 12"MI 3" WOW MANUFACTURER. <br /> 0 <br /> 6"WOOD TRIM BACKER ROD O 06 <br /> &SEALANT <br /> J <br /> FRY REGLET P w Ld <br /> "J„TRIM i5 3 U) <br /> 6"WOOD TRIM // c0c � N <br /> G WOOD SIDING PER ELEV / Q <br /> SEE 6=B FOR , ' Q Z Q <br /> TYP NOTES <br /> JAMB FLASHING PAPER 16"MAX < Q <br /> @ BOTH SIDES OF OPENING. PMIN 3 ER SIDE <br /> LAP OVER TOP OF SILL 0 <br /> ELEVATION C-C SILL FLASHING.LEAVE BOTTOM Z O = LLJ <br /> EDGE UNATTACHED 3"MIN CLEARANCE Q J OfTO CORNER TYP. of <br /> o W <br /> TYP FLASHING&SEALANT DETAILS AT WINDOWS 3.MEMBRANE JAM BF ASHING 4.MEMBRANE HEAD FLASHING 5.WINDOW INSTALLATION Q 0 c-0 W <br /> 0 <br /> ULI DJ <br /> 12"M N INSTALL SELF-ADHESIVE NOTE:KEEP FASTENERS FOR O z U <br /> 6"MIN VERT.LAPS <br /> FLEXIBLE HEAD FLASHING OVER DEPTH OF WOW/DOOR TRIM&SIDING AWAY FROM O <br /> SET VERTICAL LEG OF MTL. FRAME OF OTHER HORIZ. WDW FIN,ESPECIALLY NEAR OF BLDG.PAPER d O <br /> NAIL-ON HEAD FLANGE OF WOW HEAD FLASHING IN A BED OF LEDGE COND.+1/8". WOW CORNERS. <br /> FRAME AND OVER TOPS OF SEALANT,TYP <br /> SEE 6a JAMB FLASHING-SEAL BOTTOM 4"MIN HORIZONTAL LAPS <br /> EDGE OF FLASHING TO HEAD PERMIT SET <br /> NOTE:CONTRACTOR SHALL INSTALL BUILDING PAPER <br /> NOTE:COORDINATE MI GEOMETRY <br /> VERIFY DIMENSION, OVER SELF-ADHESIVE <br /> HEAD FLASHIN WITH WOW <br /> GEOMETRY AND CONDITION 3rd COURSE FLEXIBLE FLASHING, <br /> G PRIOR TO FABRICATION OF OF BUILDING WINDOW FRAME&METAL <br /> MANUFACTURER TO Z METAL HEAD FLASHING PAPER HEAD FLASHING. <br /> 8"MIN // ACCOMMODATE PROPER 3 <br /> / WINDOW OPERATION. `v 2nd COURSE / 08/03/23 <br /> SLOPE OUTWARD(3/6")MIN. OF BUILDING FINISH SIDING PER <br /> PAPER ELEVATIONS REVISIONS: <br /> SET MTL.HEAP FLASHING IN A NO. DESCRIPTION DATE <br /> BED OF SEALANT,EACH END SLIP BOTTOM OF SILL& <br /> TO CREATE AN END DAMN 1st COURSE JAMB FLASHING PAPER <br /> OF BUILDING OVER BUILDING PAPER @ <br /> TYPE EXTEND FLASHING MIN.1/4" PAPER BOTTOM OF WINDOW SILL <br /> PAST VERTICAL SEALANT JOINT <br /> BETW.SIDING/TRIM/JAMB <br /> FRAME,TYP. COORDINATE BOT.EDGE <br /> EDGE OF WOW FRAME OR OF BLDG.PAPER WITH <br /> JAMB TRIM - - EXT. <br /> WALL BASE DETAIL <br /> 6.HEAD FLASHING SEQUENCE 6a.METAL HEAD FLASHING 7.BUILDING PAPER APPLICATION <br /> FLASHING&NAILFLANGE WINDOWS INSTALLATION <br /> Project Manage, MTBG <br /> Drew by: MG <br /> _ FIELD VERIFY JAMB MUST ACCOMMODATE Job No: 22_0130 <br /> DOOR WIDTH THICKNESS OF ALL Scale: As indicatetl <br /> &WIDTH OF SILL FLASHING <br /> MATERIAL-VERIFY W/MFR. <br /> WALL SHEATHING VERIFY DOOR INSTALLATION <br /> PER STRUC. REQUIREMENTS WITH DOOR <br /> MANUFACTURER <br /> COORDINATE PAN FLASHING <br /> SHEATHING WITH EXT.W.P.MEMBRANE <br /> EDGES FLUSH W/ ' <br /> E <br /> FRAME OPENING <br /> �., <br /> SELF-ADHESIVE 34' <br /> FLEXIBLE <br /> INTERIOR FLOOR FLASHING WRAP <br /> OVER SILL-CUT& ALUMINUM <br /> ALL SURFACES TO EXTEND AT JAMB ELF-ADHESIVE 3/4" PAN FLASHING SHEET NAME: <br /> BE CLEAN AND FLEXIBLE - WINDOW&DOOR <br /> PROPERLY PREPPED CUT&EXTEND AT COUNTER FLASH 4" WATERPROOF DETAILS <br /> FOR FLASHING AND JAMB <br /> W.P.MATERIALS. <br /> n 1.FRAMED OPENING 2.SELF ADHESIVE FLEXIBLE 3.SELF ADHESIVE FLEXIBLE 4.ALUMINUM PAN FLASHING 5.COUNTER FLASH @JAMB NOTE:INSTALL DOOR PER TYP <br /> FLASHING INSTALLATION COUNTER FLASHING <br /> AND INSTALL DOOR FLASHING AND WINDOW/DOOR SHEET No.: <br /> INSTALLATION DETAIL <br /> 2 DOOR PAN A5.1 <br />