6504 HIGHLAND DR 2023 Plans 2025-03-27
>
Address Records
>
HIGHLAND DR
>
6504
>
Plans
>
6504 HIGHLAND DR 2023 Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 10:44:37 AM
Creation date
3/27/2025 10:43:35 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
6504
Permit
B2306-007
Year
2023
Notes
ATTACHED GARAGE CONVERTED TO ADU AND REMODEL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION STEPS: <br /> WOOD SIDING PER ELEV <br /> 1/2"RAINSCREEN 1. CUT AND FOLD SELF-ADHESIVE FLEXIBLE SILL FLASHING INTO <br /> FRAME OPENING;LEAVE BOTTOM EDGE OF SILL FLASHING UNATTACHED. D E S I G N <br /> APPROVED W.R.B. <br /> 2. CUT AND FOLD SELF-ADHESIVE FLEXIBLE CORNER WALL SHEATHING PER <br /> EXTERIOR SHEATHING FLASHING INTO BOTH BOTTOM CORNERS OF FRAME OPENING STRUC. <br /> FLEXIBLE FLASHING,TYP 3. CUT AND FOLD SELF ADHESIVE FLEXIBLE FLASHING INTO JAMB wEmisRP�iou <br /> FRAME OPENING;LEAVE BOTTOM EDGES OF JAMB FLASHING UNATTACHED 6"WOOD TRIM cacaoess auwserspESW+�ED <br /> 4. CUT AND FOLD SELF ADHESIVE FLEXIBLE FLASHING INTO HEAD SHEATHING EDGES FLUSH TINDODCUN rneDTHEpErs�DD.I.. <br /> W/FRAME OPENING c aowasn—N,ISIHECOPERrvorcacsDESEN, <br /> EXTEND MTL. 1/4° FRY REGLET EXTRUDED GVVB FRAMEOPENING. `` MAY <br /> NOT EE REUSED,IN— ART,wrMcur <br /> FLASHING ALUMINUM TRIM,MATCH THE—ENceeSn+ToFSEcaoescN. <br /> SIDING COLOR CASING 5. SEAL WINDOW FRAME TO OPENING.APPLY CONT.BEAD OF <br /> SEALANT WITHIN 1/2" r A. <br /> m LEAVE BOTTOM EDGE OF <br /> OF EDGE OF OPENING OR APPLY CONT. <br /> GAP FOR SEALANT MTL.HEAD FLASHING J H SEALANT ON BACKSIDE OF WINDOW FLANGES @HEAD,JAMB SILL FLASHING UNATTACHED �- <br /> &SEALANT TYPE d &SILL;THEN INSTALL FRAME TO OPENING. - <br /> 00 <br /> PER SIDING MNSS - "CHECK WINDOW FINS FOR DAMAGE.REPAIR OR REPLACE DAMAGED FINS.— OFFSET WALL SHEATHING A.CUT FLASHING <br /> SPECIFICATIONS A B WINDOW, 3"MIN JOINTS FROM JAMB EDGE,TYP. (2)CUTS <br /> "FASTENERS TO BE STAINLESS STEEL ROOFING <br /> NAILS <br /> B-B HEAD (1 1/2")OR EQUAL.MINIMUM PENETRATION INTO t12"(3"WIDER THAN <br /> 6"WOOD TRIM FRAMING TO BE 1— JAMB FLASH.PAPER) <br /> "GALVANIZED FASTENERS ALLOWED WHEN INSTALLING VINYL WINDOWS" B.FOLD INTO— <br /> CORNER <br /> ELEVATION 6"WOOD TRIM 6. WHEN INSTALLING A WINDOW:NAIL BOTTOM CORNER FIRST. - NOTE:PROPERLY PREPARE <br /> SET WINDOW.STRAIGHT,PLUMB&LEVEL BEFORE FRAMING AND SHEATHING TO <br /> TYP 1/2 X 2 P.T.RAIN FRY REGLET SECURING.PROVIDE CONTINUOUS SUPPORT OR SHIMS - FACILITATE PROPER ADHESION <br /> SCREEN BACKING 0/ "J"TRIM NOTES: UNDER FRAME OF SILL IF REQUIRED BY MFR.FASTEN FOR SELF-ADHESVE FLEXIBLE <br /> DRAIN MAT THROUGH SIDES OF FRAME.DO NOT FASTEN THROUGH HEAD FLASHING(S)AND NAIL-FLANGE <br /> BACKER ROD 1, REFER TO THE TYPICAL"FLASHING&WINDOW UNLESS PERMITTED BY WINDOW MFR. - 1.MEMBRANE SILL FLASHING WINDOW(S). 2.MEMBRANE SILL CORNER FLASHING <br /> &SEALANT INSTALLATION <br /> O THE AIL"FOSEQUE INFORMATION NG 7. INSTALL BUILDING PAPER FROM THE BOTTOM TO TOP OF THE WALL <br /> R.O.DI RELATING SILL BELOW INSTALLATION OF SELF-ADHESIVE FLEXIBLE SHINGLE EACH COARSE TO FACILITATE PROPER DRAINAGE. <br /> FLASHING&BUILDING PAPER. <br /> SEE B-8 FOR 2.SIDING TO BE INSTALLED PER MFR'S <br /> ELASTOMERIC <br /> A-AJAMB TYP NOTES SPECIFICATIONS SEALANT NOTE:IF THE SUPPLIED <br /> NAIL FLANGE CONTAINS <br /> 9"MIN PRE PUNCHED HOLES FOR <br /> PLACE EXTRA NAILING,ALL UNUSED <br /> SEALANT @ MITER HOLES MUST BE FILLED <br /> GAP FOR SEALANT S LAP RT.LEG OF JAMB CORNERS WINDOW <br /> 3p FLASHING MIN.3",TYP. FRAME BACKSIDE) <br /> W/SEALANT. <br /> SIDE) <br /> &SEALANT TYPE <br /> PER SIDING MFR'S <br /> 3"MIN WRAP INTO JAMB INSTALL FASTENERS AT <br /> SPECIFICATIONS <br /> A C CONDITION PER <br /> 12"MI 3" WOW MANUFACTURER. <br /> 0 <br /> 6"WOOD TRIM BACKER ROD O 06 <br /> &SEALANT <br /> J <br /> FRY REGLET P w Ld <br /> "J„TRIM i5 3 U) <br /> 6"WOOD TRIM // c0c � N <br /> G WOOD SIDING PER ELEV / Q <br /> SEE 6=B FOR , ' Q Z Q <br /> TYP NOTES <br /> JAMB FLASHING PAPER 16"MAX < Q <br /> @ BOTH SIDES OF OPENING. PMIN 3 ER SIDE <br /> LAP OVER TOP OF SILL 0 <br /> ELEVATION C-C SILL FLASHING.LEAVE BOTTOM Z O = LLJ <br /> EDGE UNATTACHED 3"MIN CLEARANCE Q J OfTO CORNER TYP. of <br /> o W <br /> TYP FLASHING&SEALANT DETAILS AT WINDOWS 3.MEMBRANE JAM BF ASHING 4.MEMBRANE HEAD FLASHING 5.WINDOW INSTALLATION Q 0 c-0 W <br /> 0 <br /> ULI DJ <br /> 12"M N INSTALL SELF-ADHESIVE NOTE:KEEP FASTENERS FOR O z U <br /> 6"MIN VERT.LAPS <br /> FLEXIBLE HEAD FLASHING OVER DEPTH OF WOW/DOOR TRIM&SIDING AWAY FROM O <br /> SET VERTICAL LEG OF MTL. FRAME OF OTHER HORIZ. WDW FIN,ESPECIALLY NEAR OF BLDG.PAPER d O <br /> NAIL-ON HEAD FLANGE OF WOW HEAD FLASHING IN A BED OF LEDGE COND.+1/8". WOW CORNERS. <br /> FRAME AND OVER TOPS OF SEALANT,TYP <br /> SEE 6a JAMB FLASHING-SEAL BOTTOM 4"MIN HORIZONTAL LAPS <br /> EDGE OF FLASHING TO HEAD PERMIT SET <br /> NOTE:CONTRACTOR SHALL INSTALL BUILDING PAPER <br /> NOTE:COORDINATE MI GEOMETRY <br /> VERIFY DIMENSION, OVER SELF-ADHESIVE <br /> HEAD FLASHIN WITH WOW <br /> GEOMETRY AND CONDITION 3rd COURSE FLEXIBLE FLASHING, <br /> G PRIOR TO FABRICATION OF OF BUILDING WINDOW FRAME&METAL <br /> MANUFACTURER TO Z METAL HEAD FLASHING PAPER HEAD FLASHING. <br /> 8"MIN // ACCOMMODATE PROPER 3 <br /> / WINDOW OPERATION. `v 2nd COURSE / 08/03/23 <br /> SLOPE OUTWARD(3/6")MIN. OF BUILDING FINISH SIDING PER <br /> PAPER ELEVATIONS REVISIONS: <br /> SET MTL.HEAP FLASHING IN A NO. DESCRIPTION DATE <br /> BED OF SEALANT,EACH END SLIP BOTTOM OF SILL& <br /> TO CREATE AN END DAMN 1st COURSE JAMB FLASHING PAPER <br /> OF BUILDING OVER BUILDING PAPER @ <br /> TYPE EXTEND FLASHING MIN.1/4" PAPER BOTTOM OF WINDOW SILL <br /> PAST VERTICAL SEALANT JOINT <br /> BETW.SIDING/TRIM/JAMB <br /> FRAME,TYP. COORDINATE BOT.EDGE <br /> EDGE OF WOW FRAME OR OF BLDG.PAPER WITH <br /> JAMB TRIM - - EXT. <br /> WALL BASE DETAIL <br /> 6.HEAD FLASHING SEQUENCE 6a.METAL HEAD FLASHING 7.BUILDING PAPER APPLICATION <br /> FLASHING&NAILFLANGE WINDOWS INSTALLATION <br /> Project Manage, MTBG <br /> Drew by: MG <br /> _ FIELD VERIFY JAMB MUST ACCOMMODATE Job No: 22_0130 <br /> DOOR WIDTH THICKNESS OF ALL Scale: As indicatetl <br /> &WIDTH OF SILL FLASHING <br /> MATERIAL-VERIFY W/MFR. <br /> WALL SHEATHING VERIFY DOOR INSTALLATION <br /> PER STRUC. REQUIREMENTS WITH DOOR <br /> MANUFACTURER <br /> COORDINATE PAN FLASHING <br /> SHEATHING WITH EXT.W.P.MEMBRANE <br /> EDGES FLUSH W/ ' <br /> E <br /> FRAME OPENING <br /> �., <br /> SELF-ADHESIVE 34' <br /> FLEXIBLE <br /> INTERIOR FLOOR FLASHING WRAP <br /> OVER SILL-CUT& ALUMINUM <br /> ALL SURFACES TO EXTEND AT JAMB ELF-ADHESIVE 3/4" PAN FLASHING SHEET NAME: <br /> BE CLEAN AND FLEXIBLE - WINDOW&DOOR <br /> PROPERLY PREPPED CUT&EXTEND AT COUNTER FLASH 4" WATERPROOF DETAILS <br /> FOR FLASHING AND JAMB <br /> W.P.MATERIALS. <br /> n 1.FRAMED OPENING 2.SELF ADHESIVE FLEXIBLE 3.SELF ADHESIVE FLEXIBLE 4.ALUMINUM PAN FLASHING 5.COUNTER FLASH @JAMB NOTE:INSTALL DOOR PER TYP <br /> FLASHING INSTALLATION COUNTER FLASHING <br /> AND INSTALL DOOR FLASHING AND WINDOW/DOOR SHEET No.: <br /> INSTALLATION DETAIL <br /> 2 DOOR PAN A5.1 <br />