Laserfiche WebLink
M <br /> Q <br /> ROOF FRAMING PER PLANS----_ BLKG PER STRUCT DETAIL; C/ <br /> FLR SHTG PER PLAN T/ROOF SHTG VENTING PER AR{p� L U Ee <br /> PROVIDE(1)AS EA SIDE WHERE O• <br /> HD PER PLAN SILL PLATE IS BORED, CUT OR km o <br /> FULL HT STUDS PER NOTCHED MORE THAN 7U THE LLB y <br /> ° PLAN OR HD SCHED PLATE WIDTH C C <br /> PT SILL/BOTT R& SW SHTG,TYP FULL-HT END STUDS PER HD DBL TOP It z .s i <br /> AS PER SW SCHED SCHED, (2) MIN O WALL ENDS C <br /> HD ANCHOR PER SCHED A MIN OF(2)AB SHALL BE RIM JOIST OR SOLID BLKG Lij y C <br /> (EPDXY ATR®EXIST FNDN) PROVIDED IN EA SILL SECTION WALL FRAMING PER PLAN <br /> DEL TOP R HEADER EXTEND <br /> C516 STRAP T&B; EN PER SW SCHED LLI .a ` V <br /> J EXTEND STRAP 2'-0"MIN � J � � pp <br /> T/CONC WALL - SILL/BOTT R,TYP PAST GRIND W m 'G g N <br /> 3x BLKG ABOVE& FIELD NAILING PER SW SCHED co <br /> PLATE WASHER PER SCHED,TYR BELOW WINDOW OPNG BRING m 3 N N <br /> P _ T/GRADES PLATE WASHER SCHEDULE EN PER SW SCHED,NP 0 3 v <br /> BLKG®PANEL EDGES <br /> WALL PLATE WASHER ALT. SIMPSON BPS HD& END STUDS PER SILL SHTG&NAILING PER SW SCHED 1/S3.1 - _. <br /> SIZE SIZE (NOTE 6) HD SCHED,TYP SHTG PER SW SCHED <br /> STEM WALL SIZE& •` - z a <br /> REINF PER PLAN C) I' I o 2x4 3x3x0.25 BPS 5/8-3 <br /> m "L L L 26 1 3.4.5.0.21 BPS 5/8-6 PT SILL R I PT SILL/BOTT It <br /> STEM WALL OR FTG PER PLAN <br /> f T/GONG T/STEM WALL <br /> NOTES: y (SOG BEYONp) <br /> 1. L= 6"MIN, 12"MAX s '� <br /> .i _I a-T- 2. 5/8"0 AB W/MIN 7"EMBED TYP,SEE STUD WALL OR SHEAR WALL SCHEDULE FOR SPACINGS&EMBED. r ° SEAL: <br /> 3. SILL PLATES TO BE PRESSURE TREATED, REFER TO GENERAL NOTES FOR GALV REQUIREMENTS FOR AB PER SW SCHED •' "' <br /> Y'•" .'� STEM WALL SIZE& <br /> -''' y RE NF PER PLAN <br /> FTG SIZE& REINF PER PLAN CONNECTORS&FASTENERS. (MIN%"0 O 48"OC,EMBED 7") .•',. A.D <br /> 4. HOLES IN SILL PLATES SHALL BE A MIN 1/32"TO MAX 1/16"LARGER THAN BOLT DIAMETER. FTG SIZE&REINF 0�$ TTA Ig <br /> 5. HOLES,CUTS AND NOTCHES IN TREATED SILL PLATES SHALL BE COATED W/FIELD.APPLIED P.T. LIQUID. NOTES. ANCHOR PER SW SCHED,TYP ' 'j•' PER PLAN 4�04 Sgl,F <br /> 6. BPS BEARING PLATES W/SLOTTED HOLES SHALL BE PLACED W/STANDARD CUT WASHER&NUT. 1. STRAP ABOVE AND BELOW WINDOWS TO BE ON BOTH SIDES AT DOUBLE-SIDED SHEAR WALLS. <br /> PLAN VIEW- 2. REFERENCE 12/S3.1 FOR ADDITIONAL INFO. �- <br /> SHEAR WALL HOLDOWN CONNECTION(NO RIM) TYPICAL ANCHOR BOLT INSTALLATION TYPICAL FTAO SHEAR WALL ELEVATION TYPICAL SHEAR WALL ELEVATION A 1 <br /> � �7� <br /> izn• I ,z�, � ,zsa J u9,. 4 .f;2. <br /> SCALE:NTS SCALE:NTS SCALE:NTS SCALE:NTS ION6 <br /> 6/1/23 <br /> HOLDOWN SCHEDULE (HF-WIND) W <br /> MARK MODEL#I9 ALLOWABLE UPLIFT(Les) MIN END STUD CONCRETE C.) Lu <br /> MIDWALL CORNER ENDWALL STUDSIzI FASTENERS ANCHOR[m WOf N <br /> SST816 Q 0 00 <br /> ®NEW FNDN N Lu Z Q <br /> 2 HDU2-SDS2.5 2215 (2)2z (6)Yq°0x "SDS 5/6"0 ATR 0 <br /> W/Le = 10" 0 J <br /> O EXIST FNDN w"0 ATR <br /> 2 <br /> 4 HDU4-SDS2.5 3285 (2)2x (10)Yq"Ox2Y"SIDS W//Le= <br /> 101, WOOD-FRAMED SHEAR WALL SCHEDULE p <br /> O EXIST FNDN FOR HEM-FIR FRAMING WI8d COMMON NAILS(201B IBC)&SIMPSON CATALOG 2021-2023 z Lu <br /> NOTES: WALL SHEATHING BOTTOM PLATE FRAMING CLIP MINIMUM FRAMING AT BLOCKING ANCHOR BOLT TO SILL PLATE AT ALLOWABLE SHEAR WALL � ILL! <br /> SW TYPE EDGE NAILING RIM BOARD AT ALL <br /> APA RATED ATTACHMENT TO WALL BELOW PANEL EDGES CONCRETE FOUNDATION FOUNDATION ( LE) Q <br /> 1..�HOEDOWNS SPECIFIED ARE AS MANUFACTURED BY SIMPSON STRONG-TIE CO. INC.;ACCEPTABLE EQUIVALENT THICKNESS PANEL EDGES CAPACITYP <br /> PRODUCT SUBSTITUTIONS ARE AVAILABLE FROM OTHER MANUFACTURERS WITH FOR APPROVAL. FOLLOW ALL (A Uo,,,,,z) (as) (e) (1,2,7) (B,9) SEISMIC WIND <br /> MANUFACTURER GUIDELINES NECESSARY TO ACHIEVE FULL ICC DESIGN VALUES. BASED ON 2021-2023 CATALOG. 5/"0 O 48"OC P.T. 2x <br /> 2. REFERENCE PLANS FOR ADDITIONAL STUD REQUIREMENTS WHERE OCCURS. o SW-6 15/32" 8d 0 6"OC 16d SINKER 0 5"OC LTP5 O 16"OC 11/a" 2x 2x 241 339 <br /> 3. HOLDOWN SHALL BE INSTALLED TIGHT TO STUDS WITHOUT FILLERS OR NOTCHING.DO NOT BEND ANCHORS. w 5/8"0 O 50"OC P.T. 3x <br /> ? (2) ROWS �"0 O 32"OC P.T. 2x <br /> 4. PROVIDE 1/4"x3"SQ PLATE WASHER IN BETWEEN STANDARD DOUBLE NUTS. EMBED LENGTH (Le) EQUAL TO TOP y SW-4 15/32" Bd 0 4"OC 16d SINKER O 6"OC, LTP5 O 10"OC 13/a, 2x 2x 353 495 <br /> OF CONCRETE DOWN TO TOP OF PLATE WASHER. USE SIMPSON SET-XP EPDXY AT EXISTING FOUNDATION. '0 O 40"OC P.T. 3x <br /> STAGGERED �8 <br /> 5. INDICATES HOEDOWN ON PLAN,TYP. <br /> NOTES: STUD WALL::::::, PROJECT#: 23-056 <br /> HOLDOWN SCHEDULE (8"MIN STEM WALL) 1. ALL NAILS ARE COMMON, UNO. REFERENCE GENERAL STRUCTURAL NOTES FOR NAIL DIAMETER AND LENGTH. DRAWN BY: TUT <br /> c 2. REFERENCE SHEAR WALL KEY DETAIL FOR DESCRIPTION OF TERMS. BOTT R ATTACHMENT WALL SHTG <br /> p DESIGNED BY: JAC <br /> SCALE:NTS s,en 3. PROVIDE SHEAR WALL SHEATHING AND NAILING FOR ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF SHEAR WALLS ARE DATE: DESCRIPTION <br /> TYPICALLY AT WINDOWS,DOORWAYS OR AS SHOWN ON PLAN. ADD'L BOT R NAILING AS REQ'D <br /> 4. EDGE NAILING IS REQUIRED AT ALL HOEDOWN POSTS. EDGE NAILING IS REQUIRED TO EACH STUD USED IN BUILT-UP HOEDOWN POSTS. EN 08.01.2023 REVISED PERMIT <br /> REFERENCE HOEDOWN SCHEDULE&DETAILS FOR ADDITIONAL INFORMATION. �T/SHTG <br /> 5. INTERMEDIATE FRAMING TO BE 2x MINIMUM MEMBERS UNO IN SCHEDULE.ATTACH SHEATHING TO INTERMEDIATE FRAMING WITH FIELD NAILING AT VjCLP <br /> RIM BOARD <br /> 12"OC WHERE STUDS ARE SPACED AT 16"OC AND FIELD NAILING AT 6"OC WHERE STUDS ARE SPACED AT 24"OC. (DEL RIM WHERE REO'D) <br /> 6. SIMPSON STRONG-TIE"A35"MAY BE USED IN LIEU OF"LTP5.""LTP5"CLIPS SHALL BE ORIENTED LENGTHWISE(HORIZONTAL)AT PLATE TO RIM. FURRING PER GC <br /> 2y4" USE 0.131"0x11/2"NAILS WHERE CLIPS ARE ATTACHED DIRECTLY TO FRAMING. USE 0.131"Ox2l/2"WHERE CLIPS ARE INSTALLED OVER DIAPHRAGM BIN <br /> MIN ATR ANCHOR&EPDXY SHEATHING. LTP FRAMING CLIP <br /> PER HD SCHED 7. (2)2x STUDS NAILED TOGETHER MAY BE USED IN PLACE OF SINGLE 3x STUD. DOUBLE 2x STUDS SHALL BE SECURED TOGETHER WITH (OVER OR UNDER SHTG) <br /> LL� FASTENERS OF THE SAME DIAMETER AND SPACING AS THE BOTTOM PLATE ATTACHMENT PER SCHEDULE. <br /> T�WALL B. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT-DIPPED GALVANIZED STEEL PLATE WASHERS PER 1/S3.1. EMBED ANCHOR BOLTS 7"MINIMUM EN <br /> SW INTO THE CONCRETE. PROVIDE AN ANCHOR BOLT AT EACH END OF EACH PLATE AND SHALL BE AT LEAST 7 TIMES THE ANCHOR BOLT A F JURISDICTIONAL STAMP: <br /> SHTG DIAMETER FROM THE ENDS OF THE PLATE, BUT NOT MORE THAT 1/2 THE TABULATED ANCHOR BOLT SPACING OR 12",WHICHEVER IS LESS. <br /> SEE ANCHOR BOLT DETAIL FOR PLATE WASHER REQUIREMENTS. [ALT:5/8"04'TITEN HD ANCHOR SCREWS MAY BE USED IN LIEU OF ANCHOR DO <br /> HD PER HD SCHED BOLTS AT EXISTING CONCRETE,WITH PLATE WASHER&SPACING REQUIREMENTS PER SCHEDULE.] STUD WALL <br /> HD STRAP PER HD SCHED (WHERE OCCURS) 9. PROVIDE HOT-DIPPED GALVANIZED NAILS AND CONNECTOR PLATES(FRAMING ANGLES, ETC. AT ALL PRESSURE TREATED LUMBER. REFERENCE AS <br /> (WHERE OCCURS) GENERAL STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. ) (PT)SILL R y"MAX <br /> STUDS PER PLAN (E)CONC WALL 10.PANELS MAY BE INSTALLED HORIZONTALLY IF STUDS ARE SPACED AT 16"OC MAX. <br /> ATR ANCHOR W/NUTS& 11. THE TOP EDGE OF THE WOOD STRUCTURAL PANEL SHALL BE ATTACHED TO THE UPPER TOP PLATE WITH EDGE NAILING, ROOF OR UPPER EI <br /> o --- R WASHER PER HD SCHED, LEVEL UPLIFT CONNECTORS SHALL BE ON THE SAME SIDE OF THE WALL AS THE SHEATHING. EN <br /> J ® CTRD IN WALL&FTG EPDXY ROD IN 12 NAILING.THE BOTTOM EDGE OF THE WOOD STRUCTURAL PANEL SHALL EXTEND TO AND BE ATTACHED TO THE BOTTOM OR SILL PLATE WITH EDGE <br /> z z T/FTG EXIST FOUNDATION 13. REFERENCE DETAIL BELOW FOR STAGGERED NAIL AND SCREW SPACING AT RIM BOARDS. �h <br /> 14. WALL TYPE ACCEPTABLE WITH TRUSJOIST AND BOISE CASCADE RIM JOIST AND SLOCKINO. SHEAR WALL KEY DETAIL <br /> N p 15. WHERE SHEATHING IS APPLIED ON BOTH SIDES OF A SHEAR WALL AND NAIL SPACING IS LESS THAN 6"OC ON EITHER SIDE,THE WIDTH OF <br /> w zs THE NAILED FACE OF THE FRAMING MEMBER SHALL BE 3x OR GREATER AT ADJOINING PANEL EDGES AND NAILS AT ALL PANEL EDGES SHALL <br /> NAILING TO MATCH SW _ a BE STAGGERED. ALTERNATIVELY, PANELS SHALL BE STAGGERED SO THAT EDGE JOINTS ON OPPOSITE SIDES ARE NOT LOCATED ON THE SAME SHEET TITLE: <br /> SCHED BOTT It NAILING STUD. STAGGER = SPACING <br /> G EN PER SW SCHED SCHED <br /> 16. FSW-X INDICATES FORCE TRANSFER AROUND OPENING (FTAO)SHEAR WALL. NAILING PER CORRESPONDING SHEAR WALL 3 SPACING/2 PER SCHEI <br /> REQUIREMENTS ON SCHEDULE. REFERENCE 3/S3.1 FOR ADDITIONAL DETAIL REQUIREMENTS. /8"MIN STRUCTURAL <br /> sw TYPE PER PUN PER PLAN° EDGE DIST RIMBOARD <br /> SECTIONS&DETAILS <br /> ATR IN NEW WALL&FTG 1 MIN <br /> - <br /> BTWN ROWS <br /> MIN It NAILING PER SCHHkED <br /> EDGE DIST <br /> DIAPHRAGM NAILING SHEETNUMBER: <br /> x <br /> NOTE Le = EMBED LENGTH PER HD SCHED (2)ROWS BOTTOM PLATE NAILING <br /> PLAN VIEW-SHEAR WALL HOLDOWNS AT CORNER �� TYPICAL HOLDOWN ANCHOR INSTALLATION �� WOOD-FRAMED SHEAR WALL SCHEDULE <br /> ,269. �10S 3.1 <br /> SCALE:NTS ' SCALE:NTS 12z2° SCALE:NONE ,soe� <br /> 6 <br /> 5 <br />