Laserfiche WebLink
SITE PLAN NOTES 2&0 <br /> -- - N62°51'39"w 39.78'___ - <br /> 1_ __-- .__—�� 1.CONNECT ALL UTILITIES TO UNDERGROUND CONNECTIONS EXISTING ON SITE.SEE <br /> MATE <br /> Property Line — — — ' — I 2. PROVIDE 4NOTES ONDSM00 H WALL PERFORATED DRAWINGS TT NOTEIRAIN A�PERIMETER OF FOUNDATION D E S I G <br /> u — <br /> CONNECT TO caa <br /> STORM DRAIN. Gas®eI- <br /> - 1(425)7503107 <br /> _ — — — — — _ _ _ 5'Setback Line 3.PROVIDE 4"SMOOTH WALL PERFORATED DRAIN AT FOUNDATION CRAWL SPACE AS <br /> - o — J SHOWN ON BUILDING SECTION AND CONNECT TO STORM DRAIN. <br /> 4.PROVIDE SEPARATE 4"TIGHT LINE CONNECTED TO ALL DOWNSPOUTS AND CONNECT Gecarnoasia+�wGHrs naseaem <br /> EXISTING LANDSCAPE TO REMAIN t+Q I TO STORM DRAIN. 7 HIS ooC—NTnNDTHEoes DIMSoNs <br /> a y I I 5.PROVIDE SEPARATE 4"TIGHT LINE CONNECTED TO ALL TRENCH AND YARD AR/IPJ$'_ p vOruTeDHaaE�sNmcaaa RIN—r-00 <br /> IA > �� AND CONNECT TO STORM DRAIN.-r. Hewniiiirvca-TOF—DESGN. <br /> I I Yt J YYU J ®� I I I 6.CONNECT DOMESTIC WATER LINE TO EXISTING WATER METER. y- <br /> Y I 7.-PROVIDE SEPARATE WATER CONNECTION FOR FUTURE IRRIGATION SYSTEM <br /> INCLUDE DOUBLE CHECK VALVE AND SHUT OFF. <br /> � <br /> TREE PROTECTION DURING CONSTRUCTION <br /> o I EXISTING ROOF EXISTING LANDSCAPE m <br /> w 1 TO REMAIN TO REMAIN x I I Q I 1.HE CONTRACTOR SHALL FOLLOW BEST PRACTICES TO PROTECT ANY TREES <br /> o I I W SCHEDULED TO BE RETAINED AND ALL TREES ON ADJACENT PROPERTY FROM <br /> c Z <br /> O DAMAGE.ALL TREES TO BE RETAINED WILL BE TAGGED BY HE OWNER.SHOULD <br /> dl m I w THE CONTRACTOR AT ANY TIME HAVE CONCERNS OR QUESTIONS ABOUT ANY <br /> 1 2 w m TREE HE IS TO CONTACT THE OWNER IMMEDIATELY AND THE OWNER WILL <br /> EXISTING ROOF A2.2 a CONSULT WITH HIS LANDSCAPE ARCHITECT AND/OR ARBORIST TO INSPECT THE <br /> z TO REMAIN —-—-— a Ur I TREE IN QUESTIONS AND PROVIDE THEIR RECOMMENDATIONS. <br /> Z _ <br /> I _ _ NEW ADDITION <br /> 1 I AREA:153.00 SF I <br /> EXISTING ROOF FIN.FLR=435.8' I „ <br /> I] TO REMAIN I - <br /> 1 -20 0" <br /> fi CLEARING AND GRADING NOTES <br /> ---- ---!- - -—-- <br /> --— �J 71 EXISTING TREE ^ 1.CLEAR SITE OF VEGETATION AS REQUIRED.FOR EXCAVATION OF HOUSE.PROTECT <br /> ❑ TO REMAIN I SLOPES AND CLEARED AREAS PER JURISDICTION REQUIREMENT <br /> ❑❑❑ _ NEW ENTRY WOOD I I 2 CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF IMPROVEMENTS ON <br /> CK/PORCH AND STEPS <br /> I ❑❑ ADJACENT PROPERTIES COORDINATE WITH NEIGHBORS AS REQUIRED. <br /> EXISTING ASPHALT r1t70"EVG w 3.ALL WORK AND MATERIALS TO BE IN ACCORDANCE WITH THE JURISDICTION <br /> DRIVEWAY TO REMAIN EXISTING CONCRETE .0 �- '•0• 4 STANDARDS <br /> SIDEWALK TO REMAIN. Tx 6'4'CONCRETE I 'Zeb o I 4.ALL EXISTING UTILITIES SHOWN ON PLAN WERE OBTAINED FROM FIELD SURVEY. Q <br /> 2 CAR PARKING STAIR LANDING"fa �1a - <br /> c� I EXISTING LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR SITE VERIFICATION OF ALL UTILITY LOCATIONS Q <br /> TO REMAIN NEW 24' 4"CONCRETE / AND CONDITIONS. <br /> 5.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT TELEPHONE,GAS, Otf <br /> -- __ — — — — — — — — — — _ STEPS,TYP _ _ _ 5'Setback Line / L=31.43' POWER AND CABLE UTILITIES PRIOR TO CONSTRUCTION IN ORDER FOR UTILITIES J <br /> -- — — — — — — — R=20.00' I COMPANIES TO PREPARE NECESSARY PLANS FOR THE CONNECTION TO THE <br /> 0=90"02'21' RESPECTIVE SYSTEMS.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LL-I LLJ <br /> Property Line I COORDINATE THESE ACTIVITIES DURING CONSTRUCTION. Q <br /> — — — — 6.EROSION CONTROL CONTRACTOR TO INSTALL CONTINUOUS SILT FENCING @ w� <br /> ---- - __ N 62'SP00"W 119.82' --- - ,- i BOUNDARY OF CLEARED/DISTRIBUTED AREA PER JURISDICTION STANDARDS. 0 Of O <br /> w <br /> _ o EXISTING CONCRETE Z <br /> Z ¢ <br /> -- CURB TO REMAIN I Q Q <br /> PALM AVE <br /> Z O w <br /> Q = <br /> —-— ROW W Of CD w <br /> ---- ¢ <br /> - --- ----- co Lu <br /> z <br /> 0 <br /> wwQ <br /> z <br /> 0 10 20 40 60 (i O <br /> SITE PLAN +"=10'-0" ' <br /> I 10'-0" <br /> PERMIT SET <br /> 08/03/23 <br /> REVISIONS: <br /> NO. DESCRIPTION DATE <br /> - I PERMITCOMMENTS O8/02/23 <br /> Project Manager: MTBG <br /> Draw by: MG <br /> Job No: 22-0130 <br /> Scale: As indicated <br /> SHEET NAME: <br /> SITE PLAN <br /> y, SHEET No.: <br /> A1 .1 <br />