Laserfiche WebLink
FLOOR PLAN NOTES 04 <br /> I -TYPICAL WALL CONSTRUCTION: E D S <br /> b I 3 o 11 A3.o a o EXTERIOR WALLS-2x6 STUDS 0 16"O.C.UNLESS NOTED OTHERWISE PER L <br /> STRUCTURAL. <br /> A A4.0 B C D E p"p w' G INTERIOR WALLS-2x4 8 2X6 STUDS @ 16"O.C. ` ceas.x®om+i.wx,(xz=)Taa <br /> I �'0 1 -2X6 STUDS Q PLUMBING WALLS 8 POCKET DOORS,TYPICAL <br /> ALL SWING DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL ".• wPrR T c=3 <br /> I 71'"11" FROM FACE OF STUD TO EDGE OF DOOR OPENINGS OR CENTERED BETWEEN R09 cacaoesi xicxrs asseaven <br /> 24'-03/4" PARTITIONS AS SHOWN. THiSDocuMExT,—THE iosns um DEsic++S <br /> 12'-10318" �-.,IN-0-ED HeTEN IS THEPRCIs of <br /> I -VENT ALL FANS AND DRYER VENTS TO EXTERIOR,TYPICAL <br /> o- 9'-51/8" 4'-5112" 4'-33/4° 5'-103/8" T WRI_SS Rsusse,G-DESSIN.Pns <br /> SMOKE ALARM NOTES: r�wRinsx coxssxT ov cscs osacx. <br /> 2'_8" <br /> _ I -LOCATE SMOKE ALARMS PER PLANS AND IRC R313.1 <br /> 8'-8" 4'-8" <br /> i -MULTIPLE SMOKE ALARMS TO BE INTERCONNECTED PER IRC R313.1 <br /> III •SMOKE ALARMS TO BE HARD-WIRED WITH BATTERY BACKUP PER IRC 313.2 <br /> ARGON MONOXIDE ALARM N TE <br /> ( W1 C LA M O S <br /> + I _ LOCATE CARBON MONOXIDE ALARMS(CMA)PER PLANS AND IRC 315.1;A COMBINATION <br /> I (E)BATHROOM FIRE AND CARBON MONOXIDE DETECTOR ISACCEPTABLE <br /> -CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH <br /> Q EGRESS (',`�') 50 CFMO - MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IRC R315.3 <br /> 1-HR FIRE RATED I <br /> a (E)BEDROOM 2 CRAWLSPACE VENTILATION CALCULATION <br /> WALL,REFER TO (E)BEDROOM 1 CONFIRM WITH IRC R408 <br /> SHEET A4.0 M5 RAT <br /> CLG 00 -1 CRAWLSPACE VENTING RED.=EXISTING TO REMAIN,ADDITIONAL CRAWL SPACE ADDED <br /> BEDROOM 'FT 6 SF a SF <br /> — a <br /> 2 —- - aGti"ro"--r-—-— <br /> CARPET 3'-3 S/4° MB <br /> 5 I I OSET EI )HALL <br /> ( CL HT:8.0' <br /> 1 ATTIC <br /> ACCESS AC <br /> CESS PANEL - <br /> 3 FLOOR PLAN LEGEND <br /> 400 CFM c <br /> O - REF. M2 o <br /> ^1 ro ^ 6 O HARDWIRED INNER CONNECTED SMOKE DETECTOR WITH BATTERY BACKUP <br /> ® 50 CFM (� '� S SD <br /> L—J B THRO <br /> �Ck16N_ _ _ _ _�G HT: -J 1 I o 'P�, a A30 C BACKUP <br /> INNER CONNECTED CARBON MONOXIDE WITH BATTERY <br /> p (E)KITCHEN (E)DINING ROOM CLGAHE a o' B GG HRT:G8RT:o8' ° Q <br /> CLG HT:8'-0" HALL I o <br /> VCT M3 CLG HT:B'-0° 50 CFM W2 CARPET VCT <br /> zo c ® WHOLE HOUSE VENTILATION FAN 60 CFM OR ABOVE Q <br /> t 2 I 0 DW LAUNDRY IMS (C WHv 06 <br /> I CLG HT:8'-D' H a ° O �� HEAT/VENT/LAMP REFER TO TABLE M1507.4 _J <br /> I VCT N - DS— O LLI <br /> 5 --I— — - -- --i — — — (— �/ W <br /> � I M8 o CSV=CRAWL SPACE VENT PER 2012 IRC SECTION R408, 0 CA <br /> R I i 8'-8" I V-2 318" 1 SF VENT FOR EA.150 SF,SEE MAIN FLOOR PLAN FOR CSV LOCATIONS. Q � C <br /> OUNTERTOP 5, 2„ it W3 CSV <br /> DOWNSPOUT W Q C <br /> ( I 24"x24"ATTIC <br /> I I I I (E)HALLWAY (E)LAUNDRY E( 1 NOOK (E)LIVING ROOM ACCESS PANEL c �PH� FROST PROOF HOSE BIB zQ <br /> DINING ROOM LIVING RO M (E)F� F=43e.e' Q " <br /> CLG HT:B' I 5 j� `,Y6 LEGEND NOTES: Q H <br /> i CLGVCTB (E)F/� F-435'4 VCT i ___ -----__-- 1 �J F <br /> A4.0 MASTER BEDROIJM 1.PROVIDE WATER RESISTANT GWB IN ALL WET AREAS,AND BLOCKING BEHIND ALL z � 2 � <br /> I 10 CLGHT:9'-10" I W8 FIXTURES. Q � c} L <br /> Mi CARPET io � C,, <br /> NEW WOOD LANDING M7 O L0 <br /> O 2.FURNITURE SHOWN ON PLAN IS FOR REFERENCE PURPOSES,ONLY AND IS NOT IN <br /> i DECK O O ABV Q U CO L <br /> CONTRACT.U.O.N. <br /> - - � CIS <br /> 7 <br /> az <br /> WaOEGRESS Wa NEW 24"x24" ID MAIN ENTRY DS O CWNJ _ ~ O <br /> O CONCRETE ABV W W F- <br /> 6'-0" STEPS,TYP "+ p z U <br /> o I ` NEW WOOD POST O O <br /> ( ❑ ❑ ❑ PER STRUCTURAL I <br /> ❑ 8 8 <br /> 1 °sue ,r-6" PERMIT SE <br /> 20'-0" , 3'x 6'-4"CONCRETE n •0, <br /> Setback Llne STAIR LANDING 0 '( <br /> Main Floor 777 o , 2 a 1 �, REVISIONS: OO/O3/ZJ <br /> /a„=,,�„ <br /> NO. DESCRIPTION <br /> I PERMITCOMMENTS <br /> Project Manager: <br /> Dew by: <br /> Job No: <br /> Scale: A <br /> SHEET NAME: <br /> MAIN LEVEL <br /> SHEET No.: <br /> A2.0 <br />