610 14TH ST 2023 Plans 2025-03-28
>
Address Records
>
14TH ST
>
610
>
Plans
>
610 14TH ST 2023 Plans 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 9:32:29 AM
Creation date
3/28/2025 9:29:23 AM
Metadata
Fields
Template:
Address Document
Street Name
14TH ST
Street Number
610
Permit
PW2305-004
Year
2023
Notes
REPLACE EXTG FUEL DOCK WITH NEW, ADD ON-DOCK KIOSK, RESTROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES <br /> 1. FDC STANDPIPE SPACING 150' MAX (ASCE MREP) <br /> MATCHLI S SHEET C3. 1 <br /> I I. 2. FIRE EXTINGUISHERS ON THE FUEL FLOAT WILL MAINTAIN A MINIMUM RATING OF <br /> MATCHLI E -�S E E TO THE LEFT FURTBHER AND <br /> T AWILL <br /> 30E ROM PLACED <br /> A FIREAEXTI EXTINGUISHER.SUCH <br /> (NFPA PERSON <br /> 303, NFPA WILL <br /> 10) <br /> E --- -}---❑----- -�-�Tt <br /> IL m I I I I 3. FIRE EXTINGUISHERS WITH A MINIMUM RATING OF 4A ON THE NON—FUELING <br /> ° VENDING SHELTER, SEE ❑� I I ❑� SECTION OF THE FLOAT (CLASS A EXTRA—HAZARD) WILL BE SPACED SUCH THAT <br /> N ARCHITECTURAL AND I I NO PERSON WILL BE FURTHER THAN 75' FROM A FIRE EXTINGUISHER. (NFPA <br /> a d STRUCTURAL BUILDING 10) <br /> a0i h (S B) DRAWINGS <br /> I Lll ----------+---}---------- <br /> 5 o 4. A FIRE PHONE IS REQUIRED TO BE ON SITE PER NFPA 30A SECTION 9.5.5. <br /> > I I <br /> w 1n N SHELTER ROOF LINE ------- ---_I _---'-- I I 5. EMERGENCY SWIM LADDER'S SPACED AT 200'. (UFC 4-152-01) <br /> o r m T ----------1---1---------- <br /> m I I I 6. WASHINGTON STATE CODE REQUIRES LIFE RINGS AT INTERVALS NOT TO EXCEED <br /> V N I I <br /> 200' AND BE CO—LOCATED WITH SWIM LADDERS. (ASCE MREP) <br /> IJ�" I I <br /> ----------T---T---------- FUEL DISPENSER - <br /> I GAS HIGH FLOW (22 LEGEND: <br /> ---------- F----------- I I GPM) <br /> I I <br /> FUEL DISPENSER - I I EXISTING BULKHEAD <br /> GAS HIGH FLOW (22 OVERHEAD LIGHT, SEE DOCKNOTE 5, TYP I� ® EXISTING STEEL PILE <br /> GPM) TYPL_1 <br /> ----------I I 4 4 <br /> T---T---------- O EXISTING TIMBER PILE <br /> I I ❑ I I ❑ <br /> STANDPIPE, SEE I I ---'------1--1--------- ❑� STEEL PILE A PILE HOOP <br /> NOTE 1, TYP I I STANDPIPE c3.zAc7.7 <br /> ----------t--t--------- <br /> I I F <br /> I I I e I ❑F FIRE ALARM PEDESTAL <br /> I I ---------- <br /> T'-I I <br /> T---------- C <br /> o ----------+---+--------- <br /> 1 I POTABLE WATER SPIGOT C3 2. C7.6 <br /> I I ro I ©H EMERGENCY TELEPHONE <br /> cn' STEEL PILE, TYP I I B FLAGPOLE, TYP OF 3, -- }�}---------- L' <br /> ------ -----1---------- c3.z c7 SEE ARCHITECTURAL I I DOCK LADDER <br /> .s <br /> I I DRAWINGS A C3.2 C7.7 <br /> ® LIFE RING <br /> POTABLE WATER C3.2 C7.5 <br /> SPIGOT, TYP FUEL DISPENSER - ________-_1___1__________ <br /> ----------T---T------____ <br /> GAS HIGH FLOW (22 FUEL DISPENSER - <br /> UI I F I GPM) ❑O DIESEL ULTRA—HIGH FUEL DISPENSER WITH HOSE REELS <br /> o FIRE ALARM ---------- --------- I I <br /> FLOW (38 GPM) <br /> PEDESTAL PAIR, UTILITY CHASE, TYP EMERGENCY I___I__________ <br /> ---------- <br /> I TELEPHONE, T T EMERGENCY FUEL SHUT OFF <br /> SEE NOTE 2, TYP I I SEE NOTE 4 0 l t o Q <br /> I I 52 FIRE ALARM PULL STATION <br /> B O I I ___ _}___}s ___❑ OVERHEAD LIGHT I I ❑� EMERGENCY I I FIRE ALARM [TOE] S C3.2 C7.6 <br /> PULL STATION <br /> ----------- SHUT OFF o <br /> POWER PEDESTAL (FOR SIDE—TIE MOORAGE) <br /> 13.2 C7.6 <br /> I I I I FLOAT OUTLINE <br /> o <br /> ----------i---i---------- FLOAT JOINT <br /> I I ATTENDANT SHACK, <br /> FUEL DISPENSER — SEE ARCHITECTURAL o 0 <br /> ______________ UTILITY CHASE <br /> DIESEL HIGH FLOW I I AND STRUCTURAL I I <br /> (22 GPM) ----------i---I---------- BUILDING (S B) ----------T---T---------- FLAG POLL <br /> DRAWINGS <br /> I I TRANSITION PLATES, <br /> SEE STRUCTURAL lovil <br /> o.o I I FUEL DISPENSER - <br /> 2 I h DIESEL HIGH FLOW <br /> NIA O O (22 GPM) <br /> U� <br /> MATCHLI E = SSE TO THE RIGHT FUEL FLOAT <br /> SPILL <br /> r CONTAINMENT SHED <br /> FUEL FLOAT N <br /> EaN/1111 III <br /> (I) SURFACE FEATURE PLAN 5' 15' <br /> E C2.1 C3.2 SCALE: 1:10 SCALE: 1"-10' IF SHEET IS LESS THAN 22x34 <br /> E CdC3.2 SCALE: 1:102 REDUCE SCALE ACCORDINGLY <br /> 1 0 RN. WATSONENGINEER: SCALE: PORT OF EVERETT DWG. N C3 2 W <br /> - ���o>:*ess�gl� N. W AS SHOWN <br /> ti DESIGNED BY: DATE: <br /> Port of =g'~� J H. PETERSON 04/11/2023 CENTRAL MARINA FUEL DOCK CIP NO. <br /> EVERETT 2-0-073-01 <br /> DRAWN BY: CHECKED BY: C <br /> 1601 5th Avenue,Suite 1300 �slm�a��o ati B. MACHUS S. STAINER PROJECT c <br /> ENLARGED SURFACE FEATURES N W <br /> P.O. BOX 538 MR-CM-2023-01 <br /> c� Seattle,Washington 98101 ® 04/11/2023 SS ISSUED FOR PERMIT REVIEW �a1P11 APPROVED BY: <br /> EVERETT, WA 98206 <br /> °=� (206)382-0600 Fax(206)382-0500 <br /> p/ (425) 259-3164 PROJECT N0.1600120 NO. I DATE I BY I REVISION NO. I DATE I BY I REVISION PLAN Z SHEET NO. 18 OF a <br /> a <br />