FILL WITH GROUT AS DIRECTED #4@16„o/c <br /> GENERAL CONSTRUCTION NOTES CONCRETE STRUCTURAL STEEL BY PRECAST PLANK MFGR. EA WAY d <br /> CODE: CONCRETE REQUIREMENTS: MATERIALS: _ <br /> VAULT STRUCTURAL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE = 3 <br /> LOCATION STRENGTH MAX W/C RATIO <br /> PROVISIONS OF THE 2018 IBC AS ADOPTED BY THE CITY OF EVERETT, a. STRUCTURAL STEEL SHAPES&PLATES SHALL CONFORM TO ASTM A36, <br /> WASHINGTON. WALLS&CIP LID SECTIONS 400GPSI @ 28 DAYS 0.53 b. HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM A500 GRADE B, v <br /> FTGS&GRADE SLAB 4000P5I @ 56 DAYS 0.53 Fy=42,000PSI. <br /> GENERAL DETAILS: CONC DOBIE OR CHAIR y <br /> CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO AIR CONTENT: WELDING: WIN 1.BACKER ROD IF REDD. s <br /> DETAILS SHOWN FOR SIMILAR CONDITIONS, CONC.EXPOSED TO WEATHER SHALL CONTAIN 5%-/-1%ENTRAINED AIR. CONFORM TO AWS D1.1"STRUCTRUAL WELDING CODE-STEEL". WELDERS SHALL BE S <br /> MIX DESIGN: CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS. USE E70 ELECTRODES OF <br /> DISCREPANCIES: SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN TYPE REQUIRED FOR MATERIALS TO BE WELDED. i T Y PLANK JOINT DETAIL L 2 TY GRADE S SECTION <br /> d <br /> THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY DISCREPANCY CONFORMANCE WITH THE SPECIFICATIONS.SUBMIT MIX DESIGNS TO $� li_i_ it $� u_i_ ' <br /> OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS. THE ENGINEER FOR REVIEW PRIOR TO PLACEMENT, GALVANIZING: SCALE 1-1 O SCALE 1-1/2-1 O z s_ <br /> ALL STEEL SECTIONS SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION o � <br /> SHORING&EXCAVATION: CONFORMING TO ASM A-123.REPAIRS SHALL CONFORM TO ASTM A-780 USING ZINC a <br /> THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL EXCAVATION EXPOSURE CATEGORIES: RICH PAINT.THE COATING THICKNESS FOR THE PAINT MUST BE 50%MORE THAN <br /> PROCEDURES,INCLUDING LAGGING,SHORING AND PROTECTION OF ADJACENT FREEZING THAWING FO THE SURROUNDING COATING THICKNESS,BUT NOT GREATER THAN 4.0 MILS. ADD ONE VERT FULL <br /> PROPERTY,STRUCTURES,STREETS AND UTILITIES. SULFATE SO HEIGHT REINF BAR EACH <br /> IN CONTACT w/WATER W1 SIDE OF BLOCKOUT <br /> WALL BACKFILL: CORROSION PROTECTION C1 REINFORCING BAR <br /> PRIOR TO BACKFILLING VAULT WALLS THE CONTRACTOR SHALL HAVE <br /> PLACED THE LID PLANKS AND PROVIDED A MINIMUM OF 5 DAYS OF CURE ON MATERIAL REQUIREMENTS: a PIPE SEE CIVIL FOR N <br /> MATERIAL REQUIREMENT: ••�'� .� o <br /> THE PLANK VOID FILL. CEMENT: ASTM C150, ADMIXTURES:ACI 501. PIPE SEE CIVIL FOR DIA&IE. 7 N <br /> AGGREGATES:ASTM C33. WATER:ASTM C94, REINFORCING BARS: DIA&IE. s o a.I <br /> BACKFILL SOIL: USE DEFORMED BARS CONFORMING TO ASTM A615,GRADE 60,EXCEPT AS NOTED a N. <br /> - . p 52 o <br /> SEE THE GEOTECHNICAL REPORT FOR WALL BACKFILL MATERIAL PLACING REQUIREMENTS: ON THE DRAWINGS. <br /> REQUIREMENTS AND PLACEMENT AND COMPACTION REQUIREMENTS.ALL ••• '••• •••�•• BLOCKOUT FOR PIPE <br /> PLACING: BLOCKOUT FOR PIPE <br /> COMPACTION OCCURING WITHIN 5'OF THE WALL SHALL BE COMPLETED FABRICATION AND PLACING REQUIREMENTS: ••. ,•>It.• ,n k• <br /> USING HAND OPERATED MACHINERY, PLACE CONCRETE AS NEARLY A5 PRACTICABLE TO ITS FINAL ' U V <br /> BENDING: S <br /> POSITION TO AVOID SEGREGATION. <br /> BARS SHALL BE BENT COLD. BARS PARTIALLY EMBEDDED IN CONCRETE SHALL •• ADD OWNER DIAG BARS � - •��•�ADD OWNER DIAG BARS W O) Z <br /> DEBRIS: NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERWISE OR AUTHORIZED BY EA.CORNER OF OPENING o <br /> REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE. THE ENGINEER. EA,CORNER OF OPENING i 'C g <br /> DESIGN CRITERIA CONSOLIDATION: PLACING: 3 . <br /> VERTICAL LOADS ON VAULT LID: CONSOLIDATE CONCRETE BY SUITABLE MEANS.THOROUGHLY WORK REINFORCEMENT SHALL BE SUPPORTED AND TIED TO PREVENT DISPLACEMENT BY "MAX NON SHRINK GROUT 3u M X NON SHRINK GROUT W <br /> CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS. CONSTRUCTION LOADS OR BY PLACING OF CONCRETE. VOID FILL VOID FILL <br /> *UNIFORM LIVE LOAD: =150PSF Y $ <br /> CURING REQUIREMENTS: CONCRETE COVER: CUT NO MORE THAN 1 •••�u�••• � y <br /> •HS20 TRUCK WHEEL LOADS: CURING: MINIMUM CONCRETE COVER FOR REINF.SHALL BE AS FOLLOWS,UNLESS NOTED CUT NO MORE THAN 2 i 0 m <br /> WALL VERT REINF BAR Y u, <br /> CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FORA OTHERWISE: WALL VERT REINF BAR AA,, <br /> 13'-611 14'to 30' @ BLOCKOUT W - <br /> TRACTOR: SUITABLE PERIOD OF TIME AFTER PLACEMENT. CONCRETE CAST AGAINST EARTH 3" @ BLOCKOUT ,w= <br /> FRONT AXLE =8,000 lb. K_ 00 a <br /> SINGLE REAR AXLE =32,000 lb. WEATHER CONDITIONS: CONCRETE CAST AGAINST FORMS AND 3 <br /> FRONT (REAR REARI o ADEQUATE PRECAUTIONS SHALL BE TAKEN DURING HOT AND COLD EXPOSED TO EARTH 2" WALL REINF @ PIPE PENETRATION AT CENTER OF WALL _> <br /> TRAILER: WEATHER IN ACCORDANCE WITH THE SPECIFICATIONS. <br /> SINGLE REAR AXLE 32,000 lb. S1 3/4"=1'-0" <br /> TRACTOR TRAILER o LID PLANK PLACEMENT: WET SETTINGS: < a <br /> IN NO CASE SHALL THE LID PLANKS BE PLACED BEFORE THE WALLS REINFORCEMENT ANCHOR BOLTS,OR ANY EMBEDDED ITEM WITHIN THE CONCRETE, <br /> HAVE BEEN ALLOWED A MINIMUM OF 3 DAYS OF CURE,WHEN MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN POURED WITHIN THE <br /> }COI!STD VACTOR TRUCK AVERAGE AMBIENT TEMPERATURES ARE LESS THAN 50 DEGREES FORMS. Q� <br /> El16,790 Ib, <br /> FAHRENHEIT,THE CONTRACTOR MUST ALLOW A MINIMUM CURE TIME LAP SPLICES: `�' <br /> : R <br /> 8 FRONT AXLE = _ . C <br /> OF 7 DAYS OR PROVIDE AN ADDITIONAL SET OF CYLINDERS TO BE �L <br /> o LAP ALL BARS 28°MIN UNLESS SHOWN OTHERWISE ON THESE DRAWINGS. �. gl J.K <br /> REAR AXLES =33,665 lb. BROKEN AT THE TIME OF LID PLACEMENT DEMONSTRATING A MINIMUM o 0 \ Oyu <br /> 0 8 8 I EA AXLE I CONCRETE STRENGTH OF 1,000 PSI HAS BEEN REACHED. `j '© 4-#6 PLANK Qa�aQ <br /> 'I <br /> FINISH: HOLLOW CORE PLANK ' <br /> DOWELS PLACED c <br /> ---;-- c <br /> a. CONCRETE FINISH TO BE SMOOTH WITH NO FINS,VOIDS,ROCK o ------�-------�-------}--- AT MIDDEPTH OF <br /> DOWEL TO MATCH <br /> * POCKETS,OR OTHER IRREGULARITIES. SCOPE OF WORK: = SLAB. <br /> FIRE TRUCK WHEEL LOADS: THE WORK INCLUDED 15 THE DESIGN,MANUFACTURE AND DELIVERY OF PRECAST WALL VERT REINF _ __ __ __ _ .t <br /> b, CONE SNAP TIES ARE REQUIRED AND ARE TO BE REMOVED AND PRESTRESSED CONCRETE UNITS.DESIGN PLANK FOR THE MOST CRITICAL OF THE SPACING. 12-1/2"THICK ScfUBA <br /> EPDXY SEALED AT ALL INTERIOR AND EXTERIOR WALL LOADING CONDITIONS AS SHOWN WITHIN THE DESIGN CRITERIA NOTE. SEE FND PLAN CAST IN PLACE SXONAL E� <br /> FRONT AXLE =19,000 lb. SURFACES.NO FLAT TIES ALLOWED. <br /> KEYNOTES FOR CONCRETE SLAB <br /> 0 8 B REAR AXLES 24,000 lb. THE MANUFACTURER SHALL SUBMIT STRUCTURAL CALCULATIONS AND PLACEMENT WALL REINF, . SHOWN SHADED. <br /> FRONT REARI I EA AXLE DRAWINGS SIGNED BY A WASHINGTON STATE REGISTERED CIVIL ENGINEER FOR - o GRADE SLAB REINF <br /> REVIEW PRIOR TO FABRICATION. SEE FOUNDATION ' Z <br /> 0 8 8 PLAN <br /> 4 6" SPECIAL INSPECTION PLAN THE MANUFACTURER SHALL INSTALL ALL BLOCK OUTS REQUIRED FOR STRUCTURAL o 4 AS SHOWN, H <br /> CONNECTIONS AS INDICATED ON THESE DRAWINGS, NO OTHER PENETRATIONS 31-#5 CONT. < ���� J z <br /> ARE ALLOWED WITHOUT THE PRIOR APPROVAL OF THE PLANK MANUFACTURER. ❑ ❑ _ <br /> *OUTRIGGER PAD POINT LOAD: GENERAL: _ 24"DIA Q Q <br /> DISTRIBUTED OVER 18"x18"PAD @ 15'-0"o/c =45,00016 SPECIAL INSPECTION BY A QUALIFIED INSPECTOR IS REQUIRED IN ALL HOLLOW CORE JOINTS SHALL BE GROUTED IN ACCORDANCE WITH THE o OPENINGS 3 <br /> ACCORDANCE WITH THE 2018 IBC, MANUFACTURER'S RECOMMENDATIONS. <br /> +DESIGN UNIFORM LIVE LOAD,HS-20,VACTOR TRUCK,FIRE TRUCK WHEEL QUALIFICATION: <br /> WITH THE SOIL COVERR DEAD LOAD. • , __ • __ __ Z <br /> LOAD,&OUTRIGGER APPLIED INDEPENDENTLY AND IN COMBINATION THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL OPEN METAL GRATING <br /> #5@12'o/c <br /> DEMONSTRATE COMPETENCE,TO THE SATISFACTION OF THE BUILDING 11° <br /> IMPACT&FATIGUE: OFFICIAL, OPEN METAL GRATING SHALL BE WELDED STEEL BAR GRATING AS SPECIFIED ON <br /> DUE TO THE LOW SPEEDS OF SERVICE VEHICLES OVER THE LID,AND THE REQUIREDTHE DRAWINGS.ALL STEEL GRATING AND GRATING COMPONENTS INCLUDING ITEMS ° AT PERIMETER WALL u.l <br /> VERIFICATION 8 INSPECTION: <br /> SOIL COVER OVER THE LID,INCREASES IN VEHICLE LOADS TO ACCOUNT FOR THE SPECIAL INSPECTOR SHALL PERFORM THE VERIFICATIONS& EMBEDED WITHIN THE CONCRETE SHALL BE HOT DIPPED GALVANIZED AFTER <br /> IMPACT&FATIGUE ARE NOT REQUIRED, INSPECTIONS NOTED IN THE SCHEDULE BELOW FABRICATION. W 1�— <br /> ui <br /> SUPPLIER SHALL PROVIDE ALL COMPONENTS NECESSARY TO INSTALL AND SECURE �4� KNEEWALL FTG DETAIL LID REINF @MANHOLE w/ KNEE-WALL c <br /> RAISED GRATE, INSPECTION & TESTING SCHEDULE THE GRATING IN PLACE&SHALL PROVIDE SHOP DRAWINGS DETAILING ALL <br /> 100P5F UNIFORM PEDESTIRAN LIVE LOAD COMPONENTS OF THE INSTALLATION TO THE ENGINEER FOR REVIEW P-RIOR TO S1 SCALE 3/4"=1'-0" Si SCALE NTS <br /> SOIL COVER FOR LID DESIGN: TYPES OF WORK FRea 2o1a IBc FABRICATION. <br /> PLANK MANUFACTURER SHALL BE RESPONSIBLE FOR DETERMINING THE SOIL SECTION � <br /> COVER DEPTHS USED IN THE LID DESIGN BASED ON THE VAULT AND CAST IN PLACE CONC DEFERRED SUBMITTALS 12�'� EA VOID BLOCKOUT a <br /> FINISHED GRADE ELEVATIONS AS SHOWN ON THE PERMITTED CIVIL CASS <br /> REINFORCING STEEL,PLACEMENT. P 1705.3 „ � - <br /> SOIL COVER FOR SUBSTRUCTURE DESIGN: THE FOLLOWING AREAS OF WORK SHALL BE CONSIDERED AS"DEFERRED #5 CONT. #5x #6@16 o/c EA L W <br /> SHOW ON THE LID PLAN <br /> THE SU Lu <br /> BSTRUCTURE WAS DESIGNED FOR A SOIL COVER OF 1.38FT MIN TO INSTALLATION 8 FASTENING OF PRECAST PANELS P 1705.9 SUBMITTALS"AS DEFINED IN THE 2018 IBC WAY TOP OC <br /> 4.16FT MAX. PLACEMENT OF CONCRETE C 1705.3 a. PRECAST PRESTRESSED HOLLOW CORE PLANK <br /> FOUNDATION DESIGN: VERIFYING USE OF REQUIRED DESIGN MIX P 1705.5 ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A CIVIL LL <br /> O <br /> FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES PROVIDED BY \/1 <br /> EARTH SOLUTIONS NW,LLC IN THEIR GEOTECHNICAL REPORT DATED TESTING OF THE CONCRETE FOR SPECIFIED ENGINEER LICENSED TO PRACTICE IN THE STATE OF WASHINGTON WHO HAS <br /> 03-15-2022. STRENGTH,AIR CONTENT AND SLUMP C 1705.3 CURRENT DESIGN EXPERIENCE IN THE TYPE OF WORK REVIEWED. 11 a.. N <br /> #6@8 o/c EA <br /> U H V <br /> ALLOWABLE BEARING PRESSURE: 5,000 PSF STRUCTURAL STEEL WAY BOT <br /> THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN 12'0" _ <br /> LATERAL EARTH PRESSURES:DRAINED LEVEL BACKFILL STRUCTURAL STEEL I GRATING I FABRICATION P 1704.2.5 AND SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED BY THE ENGINEER OF RECORD. <br /> AT REST CONDITION: 55 PCF EFW SOILS VERIFICATION OF SOIL-BEARING CAPACITY: OFFICIAL PRIOR TO INSTALLATION. S1 SCALE 3/4"=1'-0" co) <br /> IN PLACE LID SECTION =m�� <br /> ACTIVE CONDITION: 35 PCF EFW CONTRACTOR SHALL SUBMIT REVIEWED DWGS&CALCS TO THE BUILDING o m <br /> SEISMIC PRESSURE COMPONENT, E=BH PSF UNIFORM INSTALLATION OF DRAINAGE SYSTEM: P 1705.E LLI <br /> SATURATED SOIL DENSITY: 125 PCF PLACEMENT&COMPACTION OF WALL BACKFILL P 1705.6 WATERSTOP CURB @ GRATED OPENING z <br /> o <br /> 6m� J <br /> FREQUENCY LEGEND A <br /> PVC WATERSTOP #6@16„o/c EA m <br /> co) <br /> J <br /> C= CONTINUOUS P= PERIODIC EMB cD Ot <br /> SEE REFERENCES AND STANDARDS LISTED WITHIN THE VERIFICATION& WATER5TOP5 SHALL BE 4"RIBBED WITH CENTER BULB A5 MANUFACTURED BY = WAY TOP O N I <br /> PRESSURE RELIEF VALVE INSPECTION SCHEDULE FOR MEANING OF PERIODIC AND CONTINUOUS GREENSTREAK,INC-OR EQUIVALENT-AND SHALL BE FORMULATED FROM VIRGIN <br /> INSPECTIONS. RAW MATERIAL AND SHALL MEET THE THE ARMY CORPS OF ENGINEERS N ID d <br /> PRESSURE RELIEF VALVES SHALL BE 4"0 TROY MODEL A2580 HYDROSTATIC CERTIFICATE OF COMPLIANCE: STANDARD SPECIFICATION CRD-C 572-74.INSTALL WATERSTOP IN ACCORDANCE a e W D^� <br /> WITH ALL OF THE MANUFACTURERES RECOMMENDATION.SPLICING OF THE N � <br /> RELIEF VALVE AND WALL THIMBLE WITH REMOVABLE GRATE. THE SPECIAL INSPECTION AGENCY SHALL PROVIDE A FINAL LETTER WATERSTOP SHALL BE ACCOMPLISHED WITH A THERMOSTATICALLY CONTROLLEDE G F <br /> CERTIFICATE OF COMPLIANCE STATING THAT THE REVIEWED WORK WAS SPLICING IRON IN ACCORDANCE WITH THE MANUFACTURERS DIRECTION AND -4 3 (n <br /> CONTRACTOR MAY SUBMIT ALTERNATE VALVE TYPES FOR CONSIDERATION. COMPLETED IN ACCORDANCE WITH THE PERMITTED DOCUMENTS. jV <br /> RECOMMENDATIONS, � <br /> SUBMIT ALL DOCUMENTS RELATED TO THE ALTERNATE,INCLUDING 11 _ o'o_ d <br /> INSTALLATION DETAILS TO THE ENGINEER FOR REVIEW.VALVES SHALL BE SUBMITTAL OF REPORTS: BENTONITE CLAY WATERSTOP <br /> #6@8 o/c EA - <br /> SHOWN TO OPEN AT A PRESSURE DIFFERENTIAL NOT EXCEEDING 9"OF ALL SPECIAL INSPECTION REPORTS AND TESTING REPORTS SHALL BE WATERSTOP SHALL BE RX-101 AS MANUFACTURED BY CETCO OR EQUIVALENT. WAY BOT <br /> WATER HEAD.ALTERNATE VALVES SHALL BE FULLY SERVICABLE TO SUBMITTED TO THE OWNER,SITE STRUCTURES AND THE BUILDING INSTALL WATERSTOP IN ACCORDANCE WITH ALL OF THE MANUFACTURERS VAULT PERIMETER <br /> MAINTAIN PROPER OPERATION OVER THE LIFE OF THE STRUCTURE. OFFICIAL BY THE AGENCY PERFORMING THE INSPECTION OR TESTING. RECOMMENDATIONS,WATERSTOP SHALL BE ATTACHED TO THE CONCRETE WALL EXTEND VERT KNEE WALL @ GRATED f SHEET: <br /> SURFACE USING A CONTINUOUS BEAD OF CETCO CETSEAL OR SHALL BE REINF 11" INTO CIP LID OPENING.EXTEND VERT <br /> MECHANICALLY FASTENED TO THE CONCRETE SURFACE WITH CETCO REVO-FIX AS REINF 1111 INTO CIP LID <br /> REQUIRED BY THE TECHNICAL DATA SHEET FOR WATERSTOP-RX. 9'-4 <br /> WATERSTOP SHALL BE PROTECTED AGAINST EXPOSURE TO WATER FROM ANY CAST IN PLACE LID SECTION Si OF 4 <br /> SOURCE UNTIL THE CONCRETE ENCASING THE WATERSTOP IS PLACED AT THE <br /> JOINT. S1 SCALE 3/4114-0" <br /> S-22-070 <br />