Laserfiche WebLink
April 12, 2021 <br />www.dykeman.net 1716 West Marine View Drive <br />425,259,3161 (T) 2nd Floor / Everett, WA 98201 <br />9 D E"ENE <br />APR 13 ppjl 0 <br />James Bronder— Plans Examiner CITY OF EVERETT <br />City of Everett Planning and Public Works. Permit Services <br />3200 Cedar Street <br />Everett, WA 98201 <br />RE: Community Transit Maintenance Improvements and Expansion, B2101-001 and M2101-014 <br />Dear: Mr. Bonder, <br />This letter contains responses to your correction notices dated March 16, 2021 and March 26, 2021. <br />Responses to comments are in Italics below. <br />ARCHITECTURAL — B2101-001 <br />The report on Hazardous Materials Storage (dated 12-21-2020), indicates that the Expected <br />Storage of Hazardous Materials (Table 4) are exceeding the increased Limits for Sprinklered <br />Buildings (Table 2). Based on the conditions described, this would require an occupancy of H-2 or <br />H-3 occupancy. The report concludes that "...Community transit will implement storage and <br />management practices to maintain the stored quantities within the allowable limits.". Please <br />indicate what these storage and management practices are such that the allowable storage <br />limitations are maintained under the IBC and IFC provisions as it is currently unclear from the report <br />how this is being achieved or identify on the plans where such H occupancies are occurring on the <br />construction plans as it pertains to hazardous materials per IBC 307.1. <br />Per the original construction documents, the existing Acetylene Tank and Oxygen Tank <br />storage rooms are 1-hour rated, accessory H-3 uses, as noted on sheets CS1.1 and A1.11- <br />MB. <br />The Paint Mixing room, located outside the main building to the west, is a prefabricated, 2- <br />hour rated room and is listed as an H-3 accessory use on sheets CS1.1 and A1.11-MB. <br />Other materials are to be stored in existing and new flammable safety cabinets located <br />throughout the facility. These cabinets and capacities are shown on sheets CS1.1. <br />STRUCTURAL — B2101-001 <br />2. Permit calculations appear to include wind out -of -plane wall checks. However, it appears that out - <br />of -plane wall loading from ASCE 7-10 Sec. 12.11.1 may govern the design. Please verify and <br />provide additional calculations that proposed walls are adequate. <br />See attached response letter from the Structural Engineer. <br />3. Permit calculations indicate global diaphragm checks. However, it appears that the out -of -plane <br />anchorage connection design calculations are missing for metal deck diaphragms. Please indicate <br />or provide additional calculations addressing these elements. ASCE 710 Sec 12.11.2.1, <br />12.11.2.2.2. <br />See attached response letter from the Structural Engineer. <br />CIAD-�- 0 <br />ARCHITECTURE + DESIGN <br />