My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9826 7TH AVE SE 2025-06-25
>
Address Records
>
7TH AVE SE
>
9826
>
9826 7TH AVE SE 2025-06-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2025 11:13:52 AM
Creation date
4/1/2025 1:59:20 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
9826
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The comments below were generated from this project's City of Everett Sewer Reviewers. All questions shall be routed through this project's Public Works <br />Reviewer Thad Newport with City of Everett Permit Services (TNewport@everettwa.gov). <br /># <br />Document <br />Sht/Pg <br />Reviewer's Comment <br />Designer's Response <br />Initials <br />1 <br />Civil Plans <br />— <br />Provide peak flow modeling information in gpm for projected <br />MGS Flood has been used to model peak <br />sewer outfall so the City can verify sewer capacity. <br />flows for the Nelson and Pacific Pride basins <br />(0.163 acres). Results have been included <br />with this submittal. <br />The comments below were generated from this project's City of Everett Industrial Pretreatment Reviewers. All questions shall be routed through this <br />project's Public Works Reviewer Thad Newport with City of Everett Permit Services (TNewport@everettwa.gov). <br /># <br />Document <br />Sht/Pg <br />Reviewer's Comment <br />Designer's Response <br />Initials <br />1 <br />Civil Plans <br />— <br />The site plan does not indicate an oil/water separator (OWS) <br />Additional field work and research has <br />between the catch basins and the line discharging to the sanitary <br />determined there are three (3) existing <br />sewer. If any separators already exist, please indicate on the plan <br />OWS vaults on the property. There are two <br />(along with full details of the OWS, including sizing), otherwise, <br />(2) 1,000 gallon OWS vaults and one (1) 300 <br />an appropriately sized oil/water separator will need to be <br />gallon OWS vault. The survey has been <br />installed as a pretreatment system to prevent excessive amounts <br />updated to show the OWS locations and <br />of oil, sand and inert solids from entering the sanitary sewer. <br />volumes. The total volume provided by the <br />(EMC 14.40.130.C) The interceptor(s) shall be maintained in <br />existing OWS vaults is 2,300 gallons. The <br />accordance with EMC 14.40.130.D. <br />required treatment volume based on <br />drainage area is 1,833 gallons. The existing <br />site infrastructure exceeds the minimum <br />required design volume. <br />As part of the Interim Discharge Prevention <br />Plan, the project will install downturned <br />elbows on the outlet of both 1,000 gal OWS. <br />Page 2 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.