My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4929 SOUND AVE 2025-09-19
>
Address Records
>
SOUND AVE
>
4929
>
4929 SOUND AVE 2025-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2025 4:18:43 PM
Creation date
4/2/2025 10:13:58 AM
Metadata
Fields
Template:
Address Document
Street Name
SOUND AVE
Street Number
4929
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. CHAN RESIDENCE June 7, 2022 SDA Job# 9557 8 <br /> __ _a- <br /> UPPER FROM' a+5.‘NSW 3c_'M_'\', h,. . <br /> Floor Into Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level.e.g. Roof,4TH,3RD,2ND 1 tributary width 1 0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2:; total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) 0.0 tributary width 0.0 tributary area <br /> - . 2.0 total width 2.0 total area <br /> ROOF Resisting Dead Load U Tributary Area(NA) z Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 8.6 ft o tributary width a �_tributary area <br /> 1 3.8 ft 5.5 ft I I o¢ total width O total area <br /> o Tributary Area(NA) s- Tributary Area(NA) <br /> EV(ROOF)= 6958 lb 1343 lb z tributary width W tributary area <br /> EV()= 0 lb 0 lb total width `" total area <br /> EV()= 0 1b 0 1b <br /> EV()= 0 lb 0 lb Height of Shearwall= 9.0 ft Weight of Shearwall= 10 0 lbs <br /> ' E(Wind)= 6,958 lb E(Smc)= 1,343 lb Length of Shearwall= 3.8 ft Tributary width for dead load= 5.5 ft <br /> ULT. v= 403 PLF ULT. v= 78 PLF Aspect Ratio OK Length of adjoining wall= 5.0 ft <br /> R= 6.5 <br /> • <br /> - . ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No 00= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No A Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF I(2 x 0.7)=305 PLF USE <br /> Holdown Above: NO FLOOR ABOVE Wind controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 2178 lbs = 2178 lbs Wind controls-Ct(ASD eq,5): <br /> ASD T.TOTAL w/o DO= (floor above)+(this floor)= 0 lbs + 1892 lbs = 1892 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C.WL=3630 lbs Unfactored T.WL=4340 lbs SIMPSON DESIGNED HOEDOWN: <br /> CS14 <br /> Unfactored C.EQ=701 lbs Unfactored T.EQ=701 lbs FOUNDATION/INTERIOR WALLS: STHD1 O/RJ <br /> • Unfactored C.DL= 1186 lbs Unfactored C.LL/SL=945 lbs <br /> UPPER REAR I A15-WSW [SEGMENTED WALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> I ROOF Floor Level,e.g.Roof,4TH,3RD,2ND 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) 0.0 tributary width 0.0 tributary area <br /> 2.0 total width 2.0 total area <br /> L ROOF I Resisting Dead Load Tributary Area(NA) z <br /> C7 Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 24.0 ft o tributary width a tributary area <br /> 1 c c.,ft 6.8 ft 10.5 ft I I I gtotal width 9 total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 6958 lb 1343 lb z tributary width w tributary area <br /> EV()= 0 lb 0 Ib total width `" total area <br /> EV O= 0 1b 0 lb <br /> EV O= 0 lb 0 lb Height of Shearwall= 10.0 ft Weight of Shearwall= 10.0 lbs <br /> E(Wind)= 6,958 lb E(Smc)= 1,343 lb Length of Shearwall= 6.8 ft Tributary width for dead load= 6.5 ft <br /> ULT. V= 145 PLF ULT.V= 28 PLF Aspect Ratio OK Length of adjoining wall= 5.0 ft <br /> R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No Do= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Block Shear Wail <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE A <br /> Holdown Above: NO FLOOR ABOVE Wind controls sht arwell design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 870 lbs = 870 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o DO= (floor above)+(this floor)= 0 lbs + 490 lbs = 490 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C.WL=1450 lbs Unfactored T.WL=2471 lbs NO HOLDOWNS REQUIRED I OK 1 <br /> Unfactored C.EQ=280 lbs Unfactored T.EQ=280 lbs FOUNDATION/INTERIOR WALLS: I OK <br /> _ Unfactored C.DL= 1654 lbs Unfactored C.LUSL= 1361 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.