Laserfiche WebLink
Washington Stcte Energy Code—ResideridU: <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Single Family—New &Additions(effective February 1,2021) <br /> _ These requirements apply to all IRC building types, including detached one- and two-family <br /> dwelllings and multiple single-family dwellings(townhouses). <br /> Project information Contact information <br /> �Chan.pheung Custom Home <br /> I li III "'1 <br /> Instructions: This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed. Based on tl'ie size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from t:ie following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by;Component,Table R41::16.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> Authorized Representative [ Date <br /> All Climate Zones(Table R402.1.1) <br /> R-Value a U-Factor <br /> Fenestration U-Factor b n;a 0.30 <br /> Skylight U-Factor b n;a 0.50 <br /> Glazer) Fenestration SHGC bje n;a n/a <br /> Ceilingil a 44:' 0.026 <br /> Wood Frame Wall @,h 21 int 0.056 <br /> Floor 30 0.029 <br /> Below Grade Wall`'h 10/15/2:1 int+TB 0.042 <br /> Slab`I. R-Value& Depth 10, >ft n/a <br /> A.values are minimums. U-factors and SHGC are maximums.When insulatic n is installed in a cavity that is less <br /> a than the label or design th ckness of the insulation, the compressed R-value of the insulation from Appendix <br /> Table A101.4 shall not be less than the R-value spe,::ified in the table. <br /> b The fenestration U-factor;:olumn excludes skylightti. <br /> "10/15/21+STB" means R•10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break betwei?n the slab and the basement wall at <br /> c the interior of the baseme"it wall. "10/15/21+STB" shall be permitted to be met with R-13 cavity insulation on <br /> the interior of the baseme in wall plus R-5 continuous insulation on the interior or exterior of the wall. "STB" <br /> means R-5 thermal break Iaetween floor slab and basement wall. <br /> d R.10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> F'::r single rafter-or joist-vaulted ceilings,the insulation may be reduced to l -38 if the full insulation depth <br /> e extends over the top plate of the exterior wall. <br /> R•7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs comp ying with Section R503.1.1. If foam plastic is used; it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> r log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for <br /> g ci'mate zone 5 of ICC 400. <br /> Int.(intermediate framing) denotes framing and im:ulation as described in Section A103.2.2 including standard <br /> h framing 16 inches on center, 78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> • Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 <br />