Laserfiche WebLink
LEGEND <br /> PROPERTY LINE OF PROPOSED PROJECT o <br /> CENTER OF STREET o w <br /> EDGE OF CURB PROPERTY LINE OF ADJACENT PROPERTIES D <br /> DGE OF SIDEWALK SEWER a w aw g' <br /> WATER c o a U <br /> I AD���]LDING/ x EXISTING FENCE <br /> EXISTING STRUCTURE W/ 8 $ <br /> II 1 I I I INTER OR RENOVATION w a <br /> EXISTING STRUCTURE TO BE REMOVED <br /> x % x <br /> PROPERTY LINE±120' x x <br /> - ..' - - I = EXISTING STRUCTURE pip— . -ESIDEYARDSETBACK 27-8' — - <br /> 40 CENTER LINE OF STREET <br /> x x % 1 x x x x % x I EDGE OF CONCRETE YEN DESIGN INC <br /> Q /2606 IEI ¢m � I I ------- ROOF OUTLINE IMMrV.YENDES.COM <br /> ZL <br /> c GARAGE PROPERTY SETBACK 162ENE179TH <br /> (E) RESIDENCE SHORELINE,WA,9818155 <br /> I N WATER SHUT-OFF <br /> CONTRACTOR TO PHONE(206)432.1111 <br /> w y PROVIDE HANDRAIL 2506 CHESTNUT ST,EVERETT,WA98201 1 (n ------- EDGE OF GRAVEL <br /> Z AROUND PORCH. <br /> /a.- SEE PAGE A2.1 FOR v 1 -I APPROVAL STAMP <br /> } T - I Q EXISTING TREES/FOLIAGE <br /> WI� - -� it t ... t1-Se••_• W I Z <br /> J O t 4 - I I—od <br /> 0 <br /> 5-p ...............'.' - IN CONC.WALKWAY < +I W <br /> Q .. N <br /> :(E) RESIDENCE x I z <br /> I i .2508 CHESTNUT ST, - m I & > U I <br /> •EVERETT,WA98201 ......... <br /> N % <br /> 2a --�_____ 6 ��"""" 5'SIDEYARD SETBACK — ' — — — -J � % % I x x , <br /> % GRADING AND DRAINAGE <br /> RO PPERTYUNE±1210—� x <br /> r— WATER SHUT•OF I I. Provisions water aroundall buiile made for the ldi buildings by g uttarsontrol drain lord drainage <br /> arod catch <br /> he basins <br /> 1 basins or other necessary drainage structures and shall b_instell d <br /> I <br /> Z m 8' X �21 I where storm water disposal cannot be obtained e:,ith,:a th_ir it �r <br /> where erosion cannot be prevented by finish grading and plant'i;; <br /> ce I•" I I I Dry wells shall not be installed in areas where the soil is not well <br /> LL N drained andior porous. <br /> BUILDINGADJECENT o <br /> N Q X'a' „ 2. Grading shall be provided to insure: <br /> } 42"HIGHT MAX. I I <br /> (a)Diversion of water away from buildings. W <br /> MUST BE 30% (b)Prevention of standing water and soil saturation detrimental (n TRANSPARENT to structures and lot use. <br /> (c)That natural drainage channels or basins are not blocked or O <br /> filled. T(d)Provisions for the disposal of water from a lot. J 2 W <br /> !ei P'cta:!i-:_f_d; F g prcP:rty p L U <br /> IF BUILDING IS NOT POSITIONED AS D MOVIE y N <br /> INDICATED ON APPROVED SITE PLAN. Z W F <br /> SITE PLAN A NEW SITE PLAN SHALL BE SUBMIT- J I- <br /> o' 2k s' o' 20' JUN 13 2017 D g � z a <br /> TED.NO FURTHER INSPECTIONS WILL F <br /> SCALE 24X36 1"-10'-0" BE MADE ON THIS PROJECT UNTIL THE z a. to 3 <br /> SCALE 11X17 1"=20'-0" REVISED SITE PLAN HAS BEEN APPROV- CITY OF EVERETT LU U W F <br /> ED BY THE BUILDING/PUBLIC WORKS Permit Services W a U W <br /> DEPTS. W 2 W °u W <br /> VICINITY MAP W � 0 > <br /> PROJECT DESCRIPTION AREA TABULATIONS LOT COVERAGE SHEET INDEX ¢ U = " W <br /> INTERIOR ALTERATIONS TO EXISTING SFR.ADD CONDITIONED SPACE CIA SITE PLAN&PROJECT INFO Z O <br /> FROM GOOGLE MAPS BEDROOM EGRESS WINDOW+REMOVE KITCHEN 2506(E)MAIN LEVEL 1037 SQ-FT LL <br /> WALLS.NEW FINISHES THROUGHOUT. 2508(E)MAIN LEVEL 510 SQ-FT TOTAL LOT AREA 6000 SQ-FT A1.1 GENERAL NOTES&WINDOW&DOOR :5 Z <br /> TOTAL 1547SQ-F7 SCHEDULE - <br /> 2506(E)HOUSE 1037 SQ-FT H U <br /> UNCONDITIONED <br /> 2508 HOUSE FLOOR PLANS&GUARD <br /> 6(E)BASEMENT LEVEL 1031 SQ-FT 2506(E)GARAGE 520 SQ-FT 1 DETAIL <br /> LEGAL DESCRIPTION <br /> -•- 2506(E)GARAGE 520 SQ-FT TOTAL 2214 SQ-FT O <br /> f HATCH HEIRS 1ST ADD TO EVERETT BLK 003 D-00-LOTS 2506(E)FRONT PORCH 52 SQ-FT W <br /> 19&20 TOTAL 1603 SQ-FT <br /> It Is owners responsibility to Otablish and stake a,, a <br /> ALLOWABLE LOT COVERAGE=6000*40%=2400 SQ-FT property lines. 06 <br /> o,ii! <br /> 1 I TOTAL AREA 3150 SQ-FT PROPOSED LOT COVERAGE=2214 SQ-FT <br /> _ } J YARD CALCULATIONS (37°h)(OK) PROPANE TANKS,HEAT PUMPS AND <br /> OTHER THISSE-"- '- <br /> REAR ` <br /> YARD=20'FEET REQUIRED MAY NOT BEILOCATEDMENT RIN THE FRONT <br /> �RAWI S <br /> NO INCREASE IN LOT COVERAGE AND SIDE SETBACKS BE ON G <br /> REAR YARD=0' IMPERVIOUS COVERAGE ie FRONT YARD=20 FEET REQUIRED <br /> REQUIRE ADDITIONAL PERMITS ISSUED <br /> 2506(E)RESIDENCE ROOF EAVE 1356 SQ-FT BY THE EVERETT FIRE DEPARTMENT AT A TIMES. <br /> YARD=20' PRIOR TO INSTALLATION. <br /> SIDE YARD=5 FEET REQUIRED 2508(E)ADU ROOF EAVE 636 SQ-FT <br /> PROJECT INFORMATION SIDE YARD=5 2506(E)GARAGE ROOF EAVE 567SQ-FT HEIGHT CALCULATION 0 <br /> (E)WALKWAY 430 SQ-FT DRAWN BY F.L. <br /> OWNER HTE PROPERTIES LLC SOUTH SIDE SETBACK 5'REQUIRED TOTAL 2989 SQ-FT Additional Permits Are Required DESIGNER A.M.S. <br /> JURISDICTION EVERETT 2'S"EXISTING NONCONFORMITY AVERAGE ELEVATION 49 FT For This Project To Include: REVIEWER A.N.Y. <br /> PARCEL NUMBER 00467300301901 %HARDSCAPE=100*2989/6000=49.8% (E)2506 HOUSE HEIGHT 17'7.75"(NO CHANGE) JOB REVIEWER <br /> NO. Y-17-063 <br /> ZONING R2 REAR SETBACK 20'REQUIRED (E)2508 HOUSE HEIGHT 17'6"(NO CHANGE) El Plumbing ❑Sprinkler <br /> NO INCREASE TO IMPERVIOUS COVERAGE SCALE SEE SHEET <br /> YEAR BUILT 1919 0"EXISTING NONCONFORMITY El Fire Alarm _ <br /> LOT AREA 6000 Electrical Site Address: 2508CHESTNUTST <br /> SENSITIVE AREA NO <br /> Owner. HIE PROPERTIES U-C <br /> Tenant ITenNamel <br /> Apo.Date: 4/12/2017 <br /> Proposed Use:SFR <br /> Description: SFR REMODEL <br /> Reviewed By: <br /> _pifioe Set kJob Site Set _Fire/Planning set <br />