Laserfiche WebLink
IIIIL1 <br /> BARKER <br /> LANDSCAPE <br /> ARCHITECTS <br /> 3002 NW 68th St. <br /> Seattle,WA 98117 <br /> r r �� O� <br /> ram, ir LEGEND: b U�\ <br /> I I 1 Property Line C4? <br /> ....„___,J <br /> ' I ,..i Setbacks kQO„."`,•„o o„ <br /> •� I� • <br /> — Distribution Easement <br /> 4!4;t(Yj• ' <br /> GENERAL NOTES: - A.�E/C�.T` .I V��� Cityof Everett TYPE III <br /> 1. See Site Survey for existing conditions. / � v""' -^' < �'. • \\ ��*a a*i Landscaping <br /> 2. See CIVIL for grading,erosion control,and soil protection. Y, " ' E <br /> 3, See L1 for plant schedule. I rii ��k —moms Ci of Everett TYPE IV <br /> 4. Tree locations may be adjusted to accommodate BLDG entrances or ' �i�► /// Landscaping <br /> windows. 1 n <br /> 5. Repair areas damaged due to construction;minimize construction impact �� I �•< ,_ G / . Concrete Pavement <br /> on adjacent landscape to preserve as much existing vegetation as possible. , ' 'All improvements scheduled to remain that are damaged during theath I �� Gravel Pavement <br /> execution of the contract work shall be replaced by the Contractor at no `-1 - <br /> additional cost to the Owner. / < I - OA <br /> 6. A full sized copy of the approved construction documents shall be on site I \ < w 69'-11$" <br /> whenever construction is in progress. 0 � i .t 5' \ environmentalA� <br /> 7. Coordinate all Specifications with Drawings prior to beginning construction. '�� Conceptual WORKS <br /> 8. All utilities shown have been established by field survey or available records J, ` f Proposed Trees Comm„" Design center <br /> and should be considered approximate and not necessarily complete.It is (� \ I � f `�TMIT V • r"'"1 10I`` / <br /> 1110 <br /> the sole responsibility of the contractor to independently verify the accuracy , , '�-,, d0215N Avenue East <br /> of all utility locations shown and to further discover and avoid any other '� \ Soil Stabilizing LA Seethe,Washington 98112 <br /> utilities not shown on the plan that might be affected by construction.Cat I <br /> V <br /> (Type IV,MIN) , 206.329.8300 <br /> 1-800-424-5555 prior to all underground work. / , / 7 VIIIF y. 2°6s2e.a°s°fax <br /> 9. Keep all walkways clear and free of debris.Paved surfaces that are ,�\\ \\ I \ '/ -�%damaged during construction shall be repaired to the satisfaction of theOwner's REP at no cost to the Owner. / \ \ \ �' 0741 <br /> 10. Storage of materials and equipment will be allowed only In areas �� r ` ` ' J NOTES: Everett <br /> designated for construction or storage.Under no circumstances shall v <br /> materials be stored in public use areas of the site. \ \ , _ 1. MIN required parking lot trees:3 trees. Safe Streets <br /> 11. Primary access to the site for the Contractor during construction shall be \ ` !1« .._ \ ,i Proposed:26 trees. <br /> coordinated with the Owner's REP. 01 (� �` �i I. - j 2. All trees within the distribution easement Supportive <br /> 12. Access to existing site improvements shall be maintained at all times. N m i— < to be<25 FT tall at full maturity. Housing <br /> F� \ <s, - � , 3. See sheet L1 for detailed planting layout. <br /> <<'1- < " 6107e Bt.WAMre Dr <br /> N 1� �' .1F, i- �I. , - 'e ` Everett. 99203 <br /> LIST OF ABBREVIATIONS •A \' •� < , <br /> ARCH Architectural Drawings&Specifications ; ` \r,. < `, ' T- i V r i <br /> BLDG Building �'✓ - <br /> CIP Cast-in-Place �r `''� <br /> CIVIL Civil Engineering Drawings&Specifications I/ \ , di <br /> CONC Concrete r 0 < - " _. <br /> DIA Diameter ` -+,• 1 ` ' +� N <br /> DWG Drawing 0 r ' il-._i: 7 I _. G <br /> EA Each .._ 1_ .. _.. <br /> ETC Et Cetera / . ,yr1� -- ' ,,< `O <br /> FG Finish Grade ; � \ . ' ,111 <br /> r� ___Cade_Overylew_PJan <br /> F Fialva Surf . <br /> GALV Galvanized - < • ` — MP° <br /> HT Height <br /> IR Inner Radius `I / - - — <br /> MANF Manufacturer / / I , ,M44 ' <br /> .. - r—<Minimum �. , /1 �� <br /> OC On Center f % <br /> 0 <br /> OR Outer Radius j t Existing vegetation Y ``� <br /> ORN Omamental on slope to remain j� •`�<. , < " ,Wf� <br /> PA Planting Area -f �' 1 t e <br /> % 4 ` <br /> POC Point of Connection i / „ , i p `8'2 fi <br /> REP Representative t�� �, laotiUSe_ee[mit <br /> REQ Required �� /, - Revisions <br /> SEC Specification Section <br /> SIM Similar - Soil Stabilizing LA ,.4 •,�,• -,...�4,, '�, ••�'t�',*�������1�� <br /> SPEC Specification o ,��►�� 7I��'� �� „�6 4 <br /> STD Standard w (Type IV,MIN) % ,4, ,4�� ���t��\ ; Ornamental Effects LA <br /> P -':/v� ��'`•� .fit ''*,•ir T III,MIN <br /> TBD To be Determined \ .I � �`A. :��ate.► t. (Type ) <br /> y, <br /> TYP Typical <br /> y <br /> , .. ` S.t' <br /> UON Unless Otherwise Noted � ' ' - �---- - '• -- ---=a- � - s <br /> -- - 230'-8" Drawn hy: <br /> S ,1LlTF <br /> "� - I Checked Dy LP.M.j; <br /> NM <br /> O O Code Overview Plan Checked <br /> kedby`NN <br /> Scale:1"=20'-0" Project No. <br /> 16--029A <br /> Lo .. <br />